Heart beat and Respiration Detection Performance of CW radar Based on New Signal Model

새로운 신호모델에 의한 CW 레이다 심장박동 및 호흡검출 성능분석

  • 이병섭 (한국항공대학교 항공전자정보공학부)
  • Received : 2017.01.12
  • Accepted : 2017.02.27
  • Published : 2017.03.31

Abstract

In this paper, new signal model for bio-signal detection, i.e heart beat and respiration, using CW radar. Most research on this similar topic are based on the conventional signal model which is not correct in envisaging reflected signal from the human body. The system developed based on this conventional model can not predict exact performance of the system. So in this paper modified signal model for bio-radar is proposed and then simulation for detecting heartbeat and respiration signal in AWGN, multipath environment. The detection performance difference between two signal models are discussed.the modified

본 논문에서는 여러 곳에서 통용되고 있는 기존의 CW(continuous-wave) 레이더 송수신모델을 수정한 송수신모델을 제안한다. 최근에 심장박동과 호흡을 검출하기 위해 기존신호모델을 기반으로 CW(continuous-wave) 레이더에 대한연구가 진행 되고 있다. 그러나 이 통용되고 있는 수신모델은 인체 공학적으로 개념과 일치하지 않기 때문에 이모델을 근거로 실험을 할 경우 실제 개발되는 시스템 성능을 정확하게 예측할수 없다. 본 논문에서는 인체 공학상 개념과 일치하는 수정된 CW(continuous-wave) 레이더 송수신모델을 제안하고 가운시안 잡음rhk 다중경로 환경에서 심장박동 및 호흡검출에 대한 시뮬레이션을 수행하고 이를 기존수신모델과의 심장박동과 호흡검출에 대한 성능을 비교 분석한다.

Keywords

References

  1. Y. Xiao, J. Lin, O. B. Lubecke, V. M. Lubecke : 'Frequency-Tuning Technique for Remote Detection of Heartbeat and Respiration Using Low-Power Double-Sideband Transmission in the Ka-band' IEEE Trans. On Microwave Theory and Tech. vol. 54, No 5, May 2006, pp 2023-2032 https://doi.org/10.1109/TMTT.2006.873625
  2. Y. Xiao, J. Lin, O. B. Lubecke, V. M. Lubecke : 'A Ka-Band Low Power Doppler Radar System for Remote Detection of Cardiopulmonary Motion' Proceeding of the 2005 IEEE, Engineering in Medicine and Biology 27th Annual Conference, Sept1-4 2005,pp7151-7154
  3. C. Li, Y. Xiao, J. Lin : 'Experiment and Spectral Analysis of a Low-Power Ka-Band Heartbeat Detector Measuring From Four Sides of a Human Body' IEEE Trans. On Microwave Theory and Tech. vol. 54, No 12, Dec 2006, pp 4464-4471 https://doi.org/10.1109/TMTT.2006.884652
  4. A. D. Droitcour, O. B. Lubecke, V. M. Lubecke, J. Lin, G. T. A Kovacs : 'Range Correlation and I/Q Performance Benefits in Single-Chip Silicon Doppler Radars for Noncontact Cardiopulmonary Monitoring' IEEE Trans. On Microwave Theory and Tech. vol. 52, No 3, March 2004, pp 838-848 https://doi.org/10.1109/TMTT.2004.823552
  5. B.Lohman, O. B. Lubecke, V. M. Lubecke, P. W. Ong, M. M. Sondhi : 'A DIGITAL SIGNAL PROCESSOR FOR DOPPLER RADAR SENSING OF VITAL SIGNS' 2001 Proceeding of the 23rd Annual EMBS International Conference, Oct 25-28 2001, pp 3359-3362
  6. J. C. Lin : 'Microwave sensing of physiological movement and volume change: A review' Bioelectromagnetics, vol. 13, pp 557-565, 1992 https://doi.org/10.1002/bem.2250130610