Wireless structural health monitoring of stay cables under two consecutive typhoons

  • 투고 : 2014.02.08
  • 심사 : 2014.03.14
  • 발행 : 2014.03.25

초록

This study has been motivated to examine the performance of a wireless sensor system under the typhoons as well as to analyze the effect of the typhoons on the bridge's vibration responses and the variation of cable forces. During the long-term field experiment on a real cable-stayed bridge in years 2011-2012, the bridge had experienced two consecutive typhoons, Bolaven and Tembin, and the wireless sensor system had recorded data of wind speeds and vibration responses from a few survived sensor nodes. In this paper, the wireless structural health monitoring of stay cables under the two consecutive typhoons is presented. Firstly, the wireless monitoring system for cable-stayed bridge is described. Multi-scale vibration sensor nodes are utilized to measure both acceleration and PZT dynamic strain from stay cables. Also, cable forces are estimated by a tension force monitoring software based on vibration properties. Secondly, the cable-stayed bridge with the wireless monitoring system is described and its wireless monitoring capacities for deck and cables are evaluated. Finally, the structural health monitoring of stay cables under the attack of the two typhoons is described. Wind-induced deck vibration, cable vibration and cable force variation are examined based on the field measurements in the cable-stayed bridge under the two consecutive typhoons.

키워드

과제정보

연구 과제 주관 기관 : National Research Foundation of Korea (NRF)

참고문헌

  1. Bhalla, S. and Soh, C.K. (2003), "Structural impedance based damage diagnosis by piezo-transducers", Earthq. Eng. Struct. D., 32(12), 1897-1916. https://doi.org/10.1002/eqe.307
  2. Bendat, J.S. and Piersol, A.G. (1993), Engineering applications of correlation and spectral analysis, New York, NY, Wiley-Interscience.
  3. Cho, S., Jo, H., Jang, S., Park, J.W., Jung, H.J., Yun, C.B., Spencer Jr., B.F. and Seo, J. (2010), "Structural health monitoring of a cable-stayed bridge using smart sensor technology: data analyses", Smart Struct. Syst., 6(5-6), 461-480. https://doi.org/10.12989/sss.2010.6.5_6.461
  4. Cho, S., Lynch, J.P., Lee, J.J. and Yun, C.B. (2010), "Development of an automated wireless tension force estimation system for cable-stayed bridges", J. Intel. Mat. Syst.Str., 21(1), 361-375. https://doi.org/10.1177/1045389X09350719
  5. Fujino, Y. and Siringoringo, D.M. (2013), Lessons learned from structural monitoring of long-span bridges and a tall base-isolated building, SHMII-6, Hongkong.
  6. HM Bridge System (2012), http://hmbridge.iptime.org
  7. Ho, D.D., Lee, P.Y., Nguyen, K. D., Hong, D.S., Lee, S.Y., Kim, J.T., Shin, S.W., Yun, C.B. and Shinozuka, M. (2012), "Solar-powered multi-scale sensor node on Imote2 platform for hybrid SHM in cable-stayed bridge", Smart Struct. Syst., 9(2), 145-164. https://doi.org/10.12989/sss.2012.9.2.145
  8. Ho, D.D., Nguyen, K.D, Yoon, H.S. and Kim, J.T. (2012), "Multi-scale acceleration-dynamic strain-impedance sensor system for structural health monitoring", Int. J. Distrib. Sens. N., 2012, 1-17.
  9. Illinois Structural Health Monitoring Project (2010), Imote2 for structural health monitoring: user's guide, University of Illinois at Urbana-Champaign.
  10. Jang, S., Jo, H., Cho, S., Mechitov, K., Rice, J.A., Sim, S.H., Jung, H.J., Yun, C.B. and Spencer, B. F. (2010), "Structural health monitoring of a cable-stayed bridges using smart sensor technology: deployment and evaluation", Smart Struct. Syst., 6(5-6), 439-459. https://doi.org/10.12989/sss.2010.6.5_6.439
  11. Jo, H., Rice, J.A., Spencer, B.F. and Nagayama, T. (2010), "Development of a high-sensitivity accelerometer board for structural health monitoring", Proceedings of the SPIE, San Diego, USA.
  12. Kim, B.H. and Park, T. (2007), "Estimation of cable tension force using the frequency-based system identification method", J. Sound Vib., 304(3-5), 660-676. https://doi.org/10.1016/j.jsv.2007.03.012
  13. Kim, J.T., Park, J.H., Hong, D.S. and Ho, D.D. (2011), "Hybrid acceleration-impedance sensor nodes on Imote2-platform for damage monitoring in steel girder connections", Smart Struct. Syst., 7(5), 393-416. https://doi.org/10.12989/sss.2011.7.5.393
  14. Kim, J.T., Nguyen, K.D. and Huynh, T.C. (2013), "Wireless health monitoring of stay cable using piezoelectric strain response and smart skin technique", Smart Struct. Syst., 12(3-4), 381-397. https://doi.org/10.12989/sss.2013.12.3_4.381
  15. Ko, J.M. and Ni, Y.Q (2005), "Technology developments in structural health monitoring of large-scale bridges", Eng. Struct., 27, 1715-1725. https://doi.org/10.1016/j.engstruct.2005.02.021
  16. Li, H., Ou, J. and Zhou, Z. (2009), "Applications of optical fibre Bragg gratings sensing technology-based smart stay cables", Opt. Laser. Eng., 47, 1077-1084. https://doi.org/10.1016/j.optlaseng.2009.04.016
  17. Liang, C., Sun, F.P. and Rogers, C.A. (1996), "Electro-mechanical impedance modeling of active material systems", Smart Mater. Struct., 5(2), 171-186. https://doi.org/10.1088/0964-1726/5/2/006
  18. Lynch, J.P. and Loh, K.J. (2006), "A summary review of wireless sensors and sensor networks for structural health monitoring", Shock Vib., 38(2), 91-128. https://doi.org/10.1177/0583102406061499
  19. Ma, C.C. and Wang, C.W. (2009), "Transient strain measurements of a suspended cable under impact loadings using fiber bragg grating sensors", IEEE Sens. J., 9(12), 1998-2007. https://doi.org/10.1109/JSEN.2009.2031327
  20. Memsic Co. (2010), Datasheet of ISM400, http://www.memsic.com
  21. Meyer, J., Bischoff, R., Feltrin, G. and Motavalli, M. (2010), "Wireless sensor networks for long-term structural health monitoring", Smart Struct. Syst., 6(3), 263-275. https://doi.org/10.12989/sss.2010.6.3.263
  22. Miller, T.I., Spencer, B.F., Li, J. and Jo, H. (2010), Solar energy harvesting and software enhancements for autonomous wireless smart sensor networks, NSEL Report Series, NSEL-022.
  23. Nagayama, T., Sim, S.H., Miyamori, Y. and Spencer, B.F. (2007), "Issues in structural health monitoring employing smart sensors", Smart Struct. Syst., 3(3), 299-320. https://doi.org/10.12989/sss.2007.3.3.299
  24. Nagayama, T. and Spencer, B.F. (2007), Structural health monitoring using smart sensors, NSEL Report Series 001, University of Illinois at Urbana-Champaign.
  25. Nguyen, K.D and Kim, J.T. (2012), "Smart PZT-interface for wireless impedance-based prestress-loss monitoring in tendon anchorage connection", Smart Struct. Syst., 9(6), 489-504. https://doi.org/10.12989/sss.2012.9.6.489
  26. Nguyen, K.D and Kim, J.T. and Park, Y.H. (2013), "Long-term vibration monitoring of cable-stayed bridge using wireless sensor network", Int. J. Distrib. Sens. N., 2013, 1-9.
  27. Nguyen, K.D, Ho, D.D. and Kim, J.T. (2013), "Damage detection in beam-type structures via PZT's dual piezoelectric responses", Smart Struct. Syst., 11(2), 217-240. https://doi.org/10.12989/sss.2013.11.2.217
  28. Overschee, V.P. and Moor, B. De (1996), Subspace identification for linear system, Kluwer Academic Publisher.
  29. Park, G., Cudney, H.H. and Inman, D.J. (2001), "Feasibility of using impedance-based damage assessment for pipeline structures", Earthq. Eng. Struct. D., 30(10), 1463-1474. https://doi.org/10.1002/eqe.72
  30. Park, G., Sohn, H., Farrar, C. and Inman, D. (2003), "Overview of piezoelectric impedance-based health monitoring and path forward", Shock Vib., 35(6), 451-463. https://doi.org/10.1177/05831024030356001
  31. Park, J.H. (2009), Development of autonomous smart sensor nodes for hybrid structural health monitoring of large structures, PhD dissertation, Pukyong National University, Korea.
  32. RM Young Co. (2014), http://www.youngusa.com
  33. Rice, J.A., Mechitov, K., Sim, S.H., Nagayama, T., Jang, S., Kim, R., Spencer, Jr, B.F., Agha, G. and Fujino, Y. (2010), "Flexible smart sensor framework for autonomous structural health monitoring", Smart Struct. Syst., 6(5-6), 423-438. https://doi.org/10.12989/sss.2010.6.5_6.423
  34. Rice, J.A. and Spencer, B.F. (2009), Flexible smart sensor framework for autonomous full-scale structural health monitoring, NSEL Report Series, NSEL-018.
  35. Typhoon Warning Center (2012), http://jtwccdn.appspot.com
  36. Sim, S.H., Li, J, Jo, H., Park, J., Cho, S. and Spencer, B.F. (2011), "Automated cable tension monitoring using smart sensors", Proceedings of the Advances in Structural Engineering and Mechanics, Korea.
  37. Siringoringo, D.M. and Fujino, Y. (2008), "System identification of suspension bridge form ambient response measurement", Eng. Struct., 30(2), 462-477. https://doi.org/10.1016/j.engstruct.2007.03.004
  38. Sirohi, J. and Chopra, I. (2000), "Fundamental understanding of piezoelectric strain sensors", J. Intel. Mat. Syst. Str., 11(4), 246-257. https://doi.org/10.1106/8BFB-GC8P-XQ47-YCQ0
  39. Shimada, T. (1995), A study on the maintenance and management of the tension measurement for the cable of bridge, PhD Dissertation, Kobe University, Japan.
  40. Spencer, B.F. and Cho, S. (2011), "Wireless Smart Sensor Technology for Monitoring Civil Infrastructure: Technological Developments and Full-scale Applications", Proceedings of the ASEM'11, Seoul, Korea.
  41. Spencer, B.F., Ruiz-Sandoval, M.E. and Kurata, N. (2004), "Smart sensing technology: opportunities and challenges", Struct. Control Health Monit., 11(4), 349-368. https://doi.org/10.1002/stc.48
  42. Zhang, Y. and Lynch, J.P. (2013), "Long-term modal analysis of the new carquinez long-span suspension bridge", Proceedings of the 31st IMAC.
  43. Zui, H., Shinke, T. and Namita, Y. (1996), "Practical formulas for estimation of cable tension by vibration method", J. Struct. Eng. - ASCE, 122(6), 651-656. https://doi.org/10.1061/(ASCE)0733-9445(1996)122:6(651)

피인용 문헌

  1. Temperature effect on wireless impedance monitoring in tendon anchorage of prestressed concrete girder vol.15, pp.4, 2015, https://doi.org/10.12989/sss.2015.15.4.1159
  2. FOS-Based Prestress Force Monitoring and Temperature Effect Estimation in Unbonded Tendons of PSC Girders vol.30, pp.2, 2017, https://doi.org/10.1061/(ASCE)AS.1943-5525.0000608
  3. 영상처리기법을 이용한 장대교량 케이블의 장력 측정 vol.22, pp.2, 2018, https://doi.org/10.11112/jksmi.2018.22.2.115
  4. Preload Monitoring in Bolted Connection Using Piezoelectric-Based Smart Interface vol.18, pp.9, 2014, https://doi.org/10.3390/s18092766
  5. Tension Force Estimation in Axially Loaded Members Using Wearable Piezoelectric Interface Technique vol.19, pp.1, 2014, https://doi.org/10.3390/s19010047
  6. Hazard analysis and monitoring for debris flow based on intelligent fuzzy detection vol.7, pp.1, 2014, https://doi.org/10.12989/smm.2020.7.1.059
  7. Variability evaluation of dynamic characteristics of highway steel bridge based on daily traffic-induced vibrations vol.164, pp.None, 2014, https://doi.org/10.1016/j.measurement.2020.108074
  8. Development of Smart Sensing Technology Approaches in Structural Health Monitoring of Bridge Structures vol.2021, pp.None, 2014, https://doi.org/10.1155/2021/2615029
  9. Crack Detection in Plate-Like Structures Using Modal Strain Energy Method considering Various Boundary Conditions vol.2021, pp.None, 2021, https://doi.org/10.1155/2021/9963135