10 MV 이상 고에너지 치료 시 발생되는 광중성자의 영향

The Effect of Photoneutron Dose in High Energy Radiotherapy

  • 박병석 (삼성서울병원 방사선종양학과) ;
  • 안종호 (삼성서울병원 방사선종양학과) ;
  • 권동열 (삼성서울병원 방사선종양학과) ;
  • 서정민 (삼성서울병원 방사선종양학과) ;
  • 송기원 (삼성서울병원 방사선종양학과)
  • Park, Byoung Suk (Department of Radiation Oncology, Samsung Medical Center) ;
  • Ahn, Jong Ho (Department of Radiation Oncology, Samsung Medical Center) ;
  • Kwon, Dong Yeol (Department of Radiation Oncology, Samsung Medical Center) ;
  • Seo, Jeong Min (Department of Radiation Oncology, Samsung Medical Center) ;
  • Song, Ki Weon (Department of Radiation Oncology, Samsung Medical Center)
  • 투고 : 2013.02.18
  • 심사 : 2013.03.10
  • 발행 : 2013.03.31

초록

목 적: 10 MV 이상 고에너지 방사선 치료 시 광핵반응을 통해 광중성자가 발생된다. 광중성자는 방사선하중계수가 X선 보다 커 작은 선량에도 인체에 미치는 영향이 크므로 정확한 선량계산 및 고려가 필요하다. 이에 광자선 에너지 크기와 치료방법에 따른 광중성자의 선량변화를 공간적인 측면에서 비교 분석하였다. 대상 및 방법: 광자선의 에너지 크기에 따른 광중성자의 선량 변화를 측정하고자 동일한 치료부위의 환자를 대상으로 치료 계획을 10 MV와 15 MV conventional plan으로 각각 만들었다. 그리고 치료방법에 따른 차이에 대해 측정하고자 10 MV conventional plan과 10 MV IMRT plan을 각각 만들었다. 검출기의 위치는 광자선원으로부터 isocenter까지의 거리를 100 cm으로 정한 기준점을 $^3He$비례계수기의 중심점에 위치시키고 광중성자 선량을 측정하였다. 또한 중심점을 기준으로 couch의 longitudinal 방향으로 상방, 하방 50 cm 방향으로 각각 $^3He$비례계수기를 위치시켜 위치변화에 따른 선량변화를 측정하여 상용프로그램을 이용하여 분석하였다. 결 과: 에너지 크기에 따른 광중성자의 평균 누적선량은 10 MV, 15 MV conventional RT시 각각 $220.27{\mu}Sv$, $526.61{\mu}Sv$로 15 MV conventional RT가 평균 2.39배의 선량이 증가하였다. 동일한 에너지의 conventional RT와 IMRT의 광중성자의 평균 누적선량은 Conventional RT, IMRT 시 각각 $220.27{\mu}Sv$, $308.27{\mu}Sv$로 IMRT가 1.40배의 선량이 증가하였다. 측정위치에 따른 광중성자의 누적선량은 Conventional RT시 point 2가 3보다 10 MV에서는 약 7.1%, 15 MV에서는 3.0%로 유의하게 높게 측정되었다. 결 론: 고에너지 방사선 치료 시 광중성자에 의한 불필요한 선량을 줄이기 위해 에너지의 선택, 치료 방법의 결정 및 환자의 position을 고려해야 할 것이다. 또한 광중성자의 선량 데이터를 체계화하여 전산화계획 프로그램에 적용되는 방안을 모색하여야 할 것이다. 이는 환자에게 불필요한 선량을 최소화하고 방사선 치료로 인한 2차 암 발생확률과 부작용을 감소시킬 수 있을 것으로 사료된다.

Purpose: High-energy radiotherapy with 10 MV or higher develops photoneutron through photonuclear reaction. Photoneutron has higher radiation weighting factor than X-ray, thus low dose can greatly affect the human body. An accurate dosimetric calculation and consultation are needed. This study compared and analyzed the dose change of photoneutron in terms of space according to the size of photon beam energy and treatment methods. Materials and Methods: To measure the dose change of photoneutron by the size of photon beam energy, patients with the same therapy area were recruited and conventional plans with 10 MV and 15 MV were each made. To measure the difference between the two treatment methods, 10 MV conventional plan and 10 MV IMRT plan was made. A detector was placed at the point which was 100 cm away from the photon beam isocenter, which was placed in the center of $^3He$ proportional counter, and the photoneutron dose was measured. $^3He$ proportional counter was placed 50 cm longitudinally superior to and inferior to the couch with the central point as the standard to measure the dose change by position changes. A commercial program was used for dose change analysis. Results: The average integral dose by energy size was $220.27{\mu}Sv$ and $526.61{\mu}Sv$ in 10 MV and 15 MV conventional RT, respectively. The average dose increased 2.39 times in 15 MV conventional RT. The average photoneutron integral dose in conventional RT and IMRT with the same energy was $220.27{\mu}Sv$ and $308.27{\mu}Sv$ each; the dose in IMRT increased 1.40 times. The average photoneutron integral dose by measurement location resulted significantly higher in point 2 than 3 in conventional RT, 7.1% higher in 10 MV, and 3.0% higher in 15 MV. Conclusion: When high energy radiotherapy, it should consider energy selection, treatment method and patient position to reduce unnecessary dose by photoneutron. Also, the dose data of photoneutron needs to be systematized to find methods to apply computerization programs. This is considered to decrease secondary cancer probabilities and side effects due to radiation therapy and to minimize unnecessary dose for the patients.

키워드