DOI QR코드

DOI QR Code

A Study on Performance Evaluation for the Bio-retention Non-point Source Pollution Treatment System

생물 저류 방법 적용을 통한 비점오염원 처리시설의 성능평가에 관한 연구

  • Lee, Jang-Soo (Department of Enviromental and Energy Engineering, University of Suwon) ;
  • Park, Yeon-Soo (Department of Enviromental and Energy Engineering, University of Suwon) ;
  • Cho, Wook-Sang (Department of Enviromental and Energy Engineering, University of Suwon)
  • 이장수 (수원대학교 환경에너지공학과) ;
  • 박연수 (수원대학교 환경에너지공학과) ;
  • 조욱상 (수원대학교 환경에너지공학과)
  • Received : 2013.05.16
  • Accepted : 2013.07.18
  • Published : 2013.09.30

Abstract

This study was purposed and performed to evaluate removal efficiency of non-point source pollution in the process and system based on bio-retention design criteria regulated by EPA. Basic Column Reactors (BCR) were prepared for optimal determinations of inflow rate of first rainfall runoff and composition and ratio of soil layers. Removal efficiencies of non-point source pollution from synthetic runoff and real first rainfall runoff, directly sampled from motor way and parking lot, were analyzed, respectively. Removal efficiency of SS, BOD, COD, T-N, and T-P were all shown to be more than 80%.

미국 환경 보호청(Environmental Protection Agency, EPA)의 생물저류 설계기준에 근거한 비점오염원 처리시설의 제거효율 및 성능을 분석하고자 기본 모형 실험장치(basic column reactor, BCR)와 파일럿 규모의 식생 실험 장치를 대상으로 각각 수행하였다. BCR을 이용하여 초기강우 유출수의 유입속도(유량), 식재 층의 조성 및 구성 비율, 등 처리시설의 설계에 필요한 적정인자 값을 도출하였으며 이를 식생 실험 장치에 적용하여 비점오염원의 제거 효율을 분석하였다. 비점오염원으로는 합성된 강우(synthetic rainfall)와 실제 현장(도로변과 주차장)에서 채수한 초기강우 유출수(first rainfall runoff)를 각각 사용하였다. 부유물질(Suspended Solid, SS), 생물학적 산소 요구량(Biochemical oxygen demand, BOD), 화학적 산소요구량(Chemical Oxygen Demand, COD), 총질소(Total Nitrogen, T-N), 총인(Total Phosphorus, T-P) 분석항목 모두 80% 이상을 상회하는 제거효율을 보이고 있음을 확인하였다.

Keywords

References

  1. US EPA, Minimum Standard 3.10-3.11, "General Infiltration Practices and Bioretention Basin Practices," (1999).
  2. Lee, J. H., Bang, K. W., Ketchum, J. L. H., Choe, J. S., and Yu, M. J., "First Flush Analysis of Urban Storm Runoff," Sci. Total Environ., 293, 163-175 (2002). https://doi.org/10.1016/S0048-9697(02)00006-2
  3. Barrett, M. E. Irish, JR, L. B., Malina, Jr., J. F., and Charbeneau, R. J., "Characterization of Highway Runoff in Austin, Texas, Arer," J. Environ. Eng., ASCE, 124(2), 131-137 (1998). https://doi.org/10.1061/(ASCE)0733-9372(1998)124:2(131)
  4. Lee, S. H. "A Study of soil Environment and Chemical Characterstics of Soil in Kunpo," The Industria Science Research Institute Sang Myung University, 2001.
  5. Berbee, R., mRijs, G., Brouwer, R., and van Velzen, L., "Characterization and Treatment of Runoff from Highways in the Netherlands Paved with Impervious and Pervious Aspalt," Water Environ. Res., 71(2), 189-190 (1999).

Cited by

  1. The Management Methods of Multi-Purpose Ecological Reservoir by System Thinking - Focused on Anteo Eco Park - vol.18, pp.2, 2015, https://doi.org/10.13087/kosert.2015.18.2.1
  2. A Study of Non-point Source Reduction Efficiency by Constructed Wetland installed in Flood Pumping Station vol.23, pp.1, 2014, https://doi.org/10.14249/eia.2014.23.1.67
  3. Development and Evaluation of Bioretention Treating Stormwater Runoff from a Parking Lot vol.17, pp.3, 2015, https://doi.org/10.17663/JWR.2015.17.3.221