Abstract
To examine the performance of a thin plate damper attached to coupling beam of bearing wall system, 5 specimens were designed with the variable parameters of the thickness and length of a thin steel plate, which was constructed and tested with a lateral load with up to a 5% drift ratio. The result was that the total amount of the energy dissipation of the specimen with the thin plate damper was greater than that of the standard RC specimen, and the plate buckling and plastic deformation could be seen in steel plate. The shorter the length of the damper, the higher was the lateral resistant force, but there was no apparent increase in the energy dissipation. By comparison of the experiments with the elastic buckling analysis, it was shown that the buckling force from the analysis could properly estimate the maximum value of the linear elastic range.
본 연구에서는 내력벽 시스템에 대하여 연결보의 단부에 적용이 가능한 박판형 금속감쇠기의 성능을 실험을 통하여 규명하고자 하였다. 박판형 금속감쇠기의 박판 두께와 길이를 변수로 하여 5개 시험체를 제작하였으며, 층간변위비 5%까지 반복하여 횡력을 가력하였다. 실험결과, 금속 박판에 좌굴발생 후 소성변형이 발생하면서 에너지 발산이 이루어졌으며, 기존의 일반 콘크리트 시험체보다 에너지 발산량이 크게 나타났다. 박판의 길이가 짧을수록 전단내력의 값은 증가하였으나 발산에너지의 양의 증가는 크게 나타나지 않았다. 실험 내력을 탄성좌굴해석과 비교한 결과, 해석에 의한 내력은 내력곡선 선형영역의 최대값을 적절히 예측함을 알 수 있었다.