Estimating Algorithm of Physical Activity Energy Expenditure and Physical Activity Intensity using a Tri-axial Accelerometer

3축 가속도 센서를 이용한 신체활동 에너지 소비량과 신체활동 강도 예측 알고리즘

  • 김도윤 (연세대학교 의과대학 의학공학교실) ;
  • 황인호 (재활공학연구소) ;
  • 전소혜 (연세대학교 의과대학 의학공학교실) ;
  • 배윤형 (연세대학교 의과대학 의학공학교실) ;
  • 김남현 (연세대학교 의과대학 의학공학교실)
  • Received : 2011.11.18
  • Accepted : 2011.12.22
  • Published : 2011.12.31

Abstract

Estimating algorithm of physical activity energy expenditure and physical activity intensity was implemented by using a tri-axial accelerometer motion detector of the SVM(Signal Vector Magnitude) of 3-axis(x, y, z). A total of 10 participants(5 males and 5 females aged between 20 and 30 years). The ActiGraph(LLC, USA) and Fitmeter(Fit.life, korea) was positioned anterior superior iliac spine on the body. The activity protocol consisted of three types on treadmill; participants performed three treadmill activity at three speeds(3, 5, 8 km/h). Each activity was performed for 7 minutes with 4 minutes rest between each activity for the steady state. These activities were repeated four weeks. Algorithm for METs, kcal and intensity of activities were implemented with ActiGraph and Fitmeter correlation between the data.

3축 가속도 동작감지기를 이용하여 x, y, z축에 대한 가속도 합인 SVM(Signal Vector Magnitude)를 적용한 신체활동 에너지 소비량과 신체활동 강도 예측 알고리즘을 구현하였다. 신체 건강한 20~30대 성인 남성 5명, 여성 5명을 대상으로 골반 장골능에 엑티그라프(LLC, USA)와 피트미터(Fit.life. korea)를 착용하고 트레드밀위에서 3단계 신체활동(걷기: 3km/h, 빨리 걷기: 5km/h, 러닝: 8km/h)을 수행하였다. 각 신체활동 단계별로 7분간 신체활동을 수행하고 5분간 휴식을 통하여 각 신체활동 단계별로 안정화된 상태에서 실험하였다. 이러한 실험을 1주 간격으로 4주간 반복 실험을 진행하였다. 실험결과 얻어진 엑티그라프와 피트미터의 600여개 데이터 상관관계를 분석하여 METs와 kcal 그리고 신체활동 강도를 구분하는 알고리즘을 구현하였다.

Keywords

References

  1. R. R. Pate, M. Pratt, S. N. et al., "Physical activity and public health. A recommendation from the Centers for Disease Control and Prevention and the American College of Sports Medicine", JAMA : the journal of the American Medical Association, vol.273, pp.402-7, 1995. https://doi.org/10.1001/jama.1995.03520290054029
  2. National Institutes of Health, Clinical Guidelines on the Identification, Evaluation, and Treatment of Overweight and Obesity in Adults-The Evidence Report, Obes. Res., vol.6 Suppl 2, pp.51S-209S, 1998. https://doi.org/10.1002/j.1550-8528.1998.tb00690.x
  3. I. M. Lee, H. D. Sesso and R. S. Paffenbarger, Jr., "Physical activity and coronary heart disease risk in men: does the duration of exercise episodes predict risk?", Circulation, vol.102, pp.981-6, 2000. https://doi.org/10.1161/01.CIR.102.9.981
  4. G. Reaven, "Insulin resistance, hypertension, and coronary heart disease," J. Clin. Hypertens., vol.5, pp.269-74, 2003. https://doi.org/10.1111/j.1524-6175.2003.01764.x
  5. N. Y. Leenders, T. E. Nelson and W. M. Sherman, "Ability of different physical activity monitors to detect movement during treadmill walking", Int. J. Sports Med., vol.24, pp.43-50, 2003. https://doi.org/10.1055/s-2003-37196
  6. R. H. Fagard, "Physical activity, physical fitness and the incidence of hypertension", J. Hypertens., vol.23, pp.265-7, 2005. https://doi.org/10.1097/00004872-200502000-00005
  7. J. F. Sallis and B. E. Saelens, "Assessment of physical activity by self-report: status, limitations, and future directions", Res. Q. Exerc. Sport, vol.71, pp.S1-14, 2000.
  8. A. B. Marietta, K. J. Welshimer and S. L. Anderson, "Knowledge, attitudes, and behaviors of college students regarding the 1990 Nutrition Labeling Education Act food labels", J. Am. Diet. Assoc., vol.99, pp.445-9, 1999. https://doi.org/10.1016/S0002-8223(99)00108-X
  9. P. S. Freedson, "Calibration of the Computer Science and Applications, Inc. accelerometer", Med. Sci. Sports Exerc., vol.30, pp.777-81, 1998. https://doi.org/10.1097/00005768-199805000-00021
  10. A. M. Swartz, S. J. Strath, D. R. Bassett, W. L. O'Brien, G. A. King and B. E. Ainsworth, "Estimation of energy expenditure using CSA accelerometers at hip and wrist sites", Med. Sci. Sports Exerc., vo1.32, pp.S450-S6, 2000.
  11. S. E. Crouter, J. R. Churilla and D. R. Bassett, "Estimating energy expenditure using accelerometers ", Eur. J. Appl. Physiol., vol.98, pp.601-12, 2006. https://doi.org/10.1007/s00421-006-0307-5
  12. D. P. Heil, "Predicting activity energy expenditure using the Actical (R) activity monitor", Res. Q. Exerc. Sport, vol.77, pp.64-80, 2006. https://doi.org/10.1080/02701367.2006.10599333
  13. D. Jacobi, A. E. Perrin, N. Grosman, M. F. Dore, S. Normand, J. M. Oppert and C. Simon, "Physical activity-related energy expenditure with the RTI and TriTrac accelerometers in overweight adults", Obesity, vol.15, pp.950-6, 2007. https://doi.org/10.1038/oby.2007.605
  14. K. Lyden, S. L. Kozey, J. W. Staudenmeyer and P. S. Freedson, "A comprehensive evaluation of commonly used accelerometer energy expenditure and MET prediction equations", Eur. J. Appl. Physiol., vol. 111, pp.187-201, 2011. https://doi.org/10.1007/s00421-010-1639-8
  15. D. Hendelman, K. Miller, C. Baggett, E. Debold and P. Freedson, "Validity of accelerometry for the assessment of moderate intensity physical activity in the field", Med. Sci. Sports Exerc., vol.32, pp.S442-9, 2000. https://doi.org/10.1097/00005768-200009001-00002
  16. A. Yngve, A. Nilsson, M. Sjostrom and U. Ekelund, "Effect of monitor placement and of activity setting on the MTI accelerometer output", Med. Sci. Sports Exerc., vol.35, pp.320-6, 2003. https://doi.org/10.1249/01.MSS.0000048829.75758.A0
  17. A. C. o. S. Medicine, ACSM's Guidelines for Exercise Testing and Prescription., vol.7, pp.286-99, 2005.
  18. 김윤경, 노형석, 조위덕, "가속도 센서를 이용한 보행 횟수 검출 알고리즘과 활동량 모니터링 시스템", 전자공학회논문지, 제48권, CI편 제2호, pp. 267-277, 2011.
  19. 백종훈, 윤병주, "무구속적인 측정 에 의한 사용자 활동 상태 추정 기법", 전자공학회논문지, 제46권, SP편 제5호, pp.652-661, 2009.
  20. 강동원, 최진승, 문경률, 탁계래, "3축 가속도계와 신체정보를 이용한 보행 및 주행시 에너지 소비량의 예측", 한국역학회지논문지, 제4호, pp.100-114쪽, 2008.