COMPARISON OF RESONANCE FREQUENCY ANALYSIS BETWEEN VARIOUS SURFACE PROPERTIES

임프란트 표면 처리에 따른 공명주파수 변화에 대한 연구

  • Bae, Sang-Bum (Department of Dentistry, School of Medicine, Ajou University) ;
  • Lee, Seong-Hyun (Department of Dentistry, School of Medicine, Ajou University) ;
  • Song, Seung-Il (Department of Dentistry, School of Medicine, Ajou University)
  • 배상범 (아주대학교 의과대학 치과학교실) ;
  • 이성현 (아주대학교 의과대학 치과학교실) ;
  • 송승일 (아주대학교 의과대학 치과학교실)
  • Received : 2009.07.23
  • Accepted : 2010.01.29
  • Published : 2010.03.31

Abstract

Purpose: The aim of this study is to compare the stability between Mg-incorporated implant, TiUnite and Machined implant. Materials and Methods: Premolars of 3 Mini pigs (24 months) were extracted. After 2 months later, total 27 fixtures of implants (9 of each design : Machined/ TiUnite/ Mg-incorporated) were inserted into the mandible of 3 mini-pig. Implant stability was estimated by RFA in installation to 2, 4 & 6 weeks. Statistical analysis of RFA values was performed with time and between groups using repeated measure ANOVA and turkey's multiple comparison test. Results: In analyzing the mean value for the observation periods, three types of implants yielded a slight decrease in RFA mean value after 2 week, followed by increase at 4-6 weeks. Mg incorporated oxidized implants demonstrated significantly higher RFA mean values at 6 weeks comparing other groups. The difference of RFA value with time and between groups was statistically significant. Conclusion: We concluded that Mg implants may reduce failure rates of clinical implants In the early period of bone healing and Mg implants may shorten the bone healing time from surgery to functional loading.

Keywords

References

  1. Jokstad A, Braegger U, Brunski JB et al : Quality of dental implants. Int Dent J 53 : 409, 2003.
  2. Huang HM, Chiu CL : Early detection of implant healing process using resonance frequency analysis. Clin Oral Implants Res 14 : 437, 2003, https://doi.org/10.1034/j.1600-0501.2003.00818.x
  3. Puleo DA, Thomas MV : Implant surfaces. Dent Clin N Am 50 : 323, 2006, https://doi.org/10.1016/j.cden.2006.03.001
  4. Wennerberg A, Albrektsson T : Suggested guidelines for the topographic evaluation of implant surface. Int J Oral Maxillofac Implants 15 : 331, 2000,
  5. Albreksson T, Dahl E, Enbom L et al : Osseointegraged oral implants, A swedish multicenter study of 8139 consecutively inserted Nobelpharma implants, J Periodontol 59 : 287, 1988, https://doi.org/10.1902/jop.1988.59.5.287
  6. Eckert SE, Parein A, Myshin HL et al : Validation of dental implant systems through a review of lliterature supplied by system manufactures. J Prosthet Dent 77 : 271, 1997, https://doi.org/10.1016/S0022-3913(97)70184-7
  7. Wennerberg A, Albrektsson T, Andersson B et al : A histomorphometric and removal torque study of screw-shaped titanium. Clin Oral Implants Res 6 : 24, 1995, https://doi.org/10.1034/j.1600-0501.1995.060103.x
  8. Hall J, Lausmaa J : Properties of a new porous oxide surface on titanium implants. Appl Osseointegration Res 1 : 5, 2000.
  9. Ivanoff CJ, Widmark G, Johansson C et al : Histologic evaluation of bone response to oxidized and turned titamium micro-implants in human jaw bone. Int J Oral Maxillofac Implants 18 : 341, 2003,
  10. Vanden Bogaerde L, Rangert B, Wendelhag I : Immediate/early function of Branemark System TiUnite implants in fresh extraction sockets in maxillae and posterior mandibles: an 18-month prospective clinical study. Clin Implant Dent Relat Res 7 : 121, 2005. https://doi.org/10.1111/j.1708-8208.2005.tb00055.x
  11. SuI YT : The significance of the surface properties of oxidized titanium to the bone response: Special emphasis on potential biochemical bonding of oxidized titanium implant. Biomaterials 24 : 3893, 2003. https://doi.org/10.1016/S0142-9612(03)00261-8
  12. Sui YT, Johansson P, Byon E et al : Bone response to Mgincoporated, oxidized implnats in rabbit femur: Mechanical interlocking vs Biochemical bonding. Journal of Applied Biomaterials and biomechanics 3 : 18, 2005.
  13. Sui YT, Johansson CB, Byon E et al : The bone response to oxidized bioactive and non-bioactive implants. Biomaterials 26 : 6720, 2005, https://doi.org/10.1016/j.biomaterials.2005.04.058
  14. SuI YT : On the Bone Response to Oxidized Titanium Implants: The Role of Microporous Structure and Chemical Composition of the Surface oxide in Enhanced osseointegration (thesis). Goteborg, Sweden : University of Ooteborg. 2002,
  15. SuI YT, Johansson CB, Petronis S et al : Characteristics of the surface oxides on turned and electrochemically oxidized pure titanium implants up to dielectric breakdown: The oxidized thickness, micro-pore configurations, surface roughness, crystal structure and chemical composition. Biomaterials 23 : 491, 2002. https://doi.org/10.1016/S0142-9612(01)00131-4
  16. Meredith N : Assessment of implant stability as a prognostic determinant. Int J Prosthodont 11 : 491, 1998.
  17. Barewall RM, Oates TW, Meredith N et al : Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface. Int J Oral Maxillofac implants 18 : 641, 2003.
  18. Zhou Y, Jiang T, Qian M et al : Roles of bone scintigraphy and resoonance frequency analysis in evaluating osseointegration of endosseous implant. Biomaterials 29 : 461, 2008. https://doi.org/10.1016/j.biomaterials.2007.10.021
  19. Huwiler MA, Pjetursson BE, Bosshardt DD et al : Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installation. Clin oral Implants Res 18 : 275, 2007. https://doi.org/10.1111/j.1600-0501.2007.01336.x
  20. Abrahamsson I, Bergllundh T, Linder E et al : Early bone formation adjacent to rough and turned endosseous implant surface. An experimental study in the dog. Clin Oral implants Res 15 : 381, 2004, https://doi.org/10.1111/j.1600-0501.2004.01082.x