References
- Balendra, T., 1995, 'Effectiveness of Tuned Liquid Column Dampers for Vibration Control of Towers,' Engineering Structures, Vol. 17, No. 9, pp.668-675 https://doi.org/10.1016/0141-0296(95)00036-7
- Chaiseri, P., Fujino, Y., Pacheco, B. M. and Sun, L. M., 1995, 'Interaction of Tuned Liquid Damper (TLD) and Structure-Theory, Experimental Verification and Application,' Structural Engineering Earthquake Engineering. JSCE, Vol. 6, No.2, pp. 103-112
- Chang, C. C., 1999, 'Suppression of Vortex-Excited Vibration of Tall Building using Tuned Liquid Dampers,' Journal of Wind Engineering and Industrial Aerodynamics, Vol. 83, pp.225-237 https://doi.org/10.1016/S0167-6105(99)00074-4
- Chen, Y. H., 1995, 'Flexibility of TLD to High-Rise Building by Simple Experiment and Comparion,' Computer & Structures, Vol. 57, No.5, pp. 855-861 https://doi.org/10.1016/0045-7949(95)00083-S
- Chen, Y. R., 2000, 'Optimal Damping Ratio of TLCDs,' Structural Engineering and Mechanics, Vol. 9, No.3, pp.227-240 https://doi.org/10.12989/sem.2000.9.3.227
- Chen, Y. R., 2003,. 'Active Tuned Column Damper with Propellers,' Earthquake Engineering and Structural Dynamics, Vol. 32, pp. 1627-1638 https://doi.org/10.1002/eqe.295
- Fujino, Y. and Pacheco, B. M., 1992, 'Tuned Liquid damper (TLD) for Suppressing Horizontal Motion of Structures,' Journal of Engineering Mechanics, ASCE, Vol. 118, No. 10, pp.2017-2030 https://doi.org/10.1061/(ASCE)0733-9399(1992)118:10(2017)
- Fujino, Y. and Abe, M., 1993,. 'Design Formulas for Tuned Mass Dampers Based on a Perturbation Technique,' Earthquake Engineering and Structural Dynamics, Vol. 22, pp. 833-854 https://doi.org/10.1002/eqe.4290221002
- Fujino, Y., 1993, 'Vibration Control by Multiple Tuned Liquid Dampers (MTLDs) ,' Journal of Structural Engineering, Vol. 119, No. 12, pp. 3482-3502 https://doi.org/10.1061/(ASCE)0733-9445(1993)119:12(3482)
- Kareem, A., 1983, 'Mitigation of Wind Induced Motion of Tall Building,' Journal of Wind Engineering and Industrial Aerodynamics, Vol. 11, pp.273-284 https://doi.org/10.1016/0167-6105(83)90106-X
- Kareem, A., Kijewski, T. and Tamura, Y., 1999, 'Mitigation of Motion of Tall Buildings with Recent Applications,' Wind and Structures, Vol. 2, No.3, pp. 201-251
- Kareem, A., 1990, 'Reduction of Wind Induced Motion Utilizing a Tuned Sloshing Damper,' Journal of Wind Engineering and Industrial Aerodynamics, Vol. 36, pp. 725-737 https://doi.org/10.1016/0167-6105(90)90070-S
- Modi, V. J. and Welt, F., 1987, 'Vibration Control using Nutation Dampers,' Proceeding International Conference on Flow Induced Vibrations, BHRA, England, pp. 369-376
- Sakai, F., Takaeda, S. and Tamaki, T., 1989, 'Tuned Liquid Column Damper-new Type Device for Suppression of Building Vibrations,' Proc. Int. Conf on Highrise BuiMings, Nanjing, China, pp. 926-93
- Soong, T. T., 1997, 'Passive Energy Dissipation Systems in Structural Engineering,' John Wiley & Sons
- Wakahara, T. and Fujono, Y.,1998, 'A Simple Estimation of Across-Wind Response of Tall Buildings with Tuned Liquid Damper,' Journal of Wind Engineering and Industrial Aerodynamics, No. 76, pp.37-54
- Xu, Y. L., 1991, 'Vibration Control of WindExcited Tall/Slender Structures,' University of Sydney, Ph.D
- Yalla, 2001, 'Liquid Dampers for Mitigation of Structural Response: Theoretical Development and Experimental Validation,' Ph.D. Nortre Dame