강변여과 취수시 과도한 지하수 하강을 저감시키기 위한 인공함양의 활용방안 연구

Application of the Artificial Recharge to Reduce the Ground-water Drawdown of the Riverbank Filtration

  • 이동기 (한국과학기술연구원) ;
  • 박재현 (인제대학교 토목공학과) ;
  • 박창근 (관동대학교 토목환경공학부) ;
  • 양정석 (인제대학교 건설기술연구소) ;
  • 남도현 ((주)대저토건) ;
  • 김대근 (대불대학교 토목공학과) ;
  • 정교철 (안동대학교 지구환경과학과) ;
  • 최용선 (인제대학교 시스템경영공학과) ;
  • 부성안 (농업기반공사 농어촌연구원)
  • Lee Dong-Kee (Korea Institute of Science and Technology) ;
  • Park Jae-Hyeoun (Dept. of Civil Engineering, Inje University) ;
  • Park Chang-Kun (Dept. of Civil Engineering Kwandong University) ;
  • Yang Jung-Suk (Construction Technology and Research Center, hie University) ;
  • Nam Do-Hyun (Daejeo Construction Co.,LTD) ;
  • Kim Dae-kun (Dept. of Civil&Environmental Engineering Daebul University) ;
  • Jeong Gyo-cheol (Dept. of Earth and Environmental Sciences, Andong National University) ;
  • Choi Yong-sun (Dept. of Systems Management Engineering, Inje University) ;
  • Boo Sung-an (Rural Research Institute in Korea Agricultural & Rural Infrastructure Corporation)
  • 발행 : 2004.12.01

초록

강변여과수의 과도한 취수는 제내지 지하수위 하강을 발생하게 하며 이로 인해서 제내지 농경지의 토양 건조도가 증가되어 과도한 관계용수의 보충이 필요할 뿐만 아니라 지하수위 하강으로 인한 기존 관정사용이 어려워져 더 깊은 새로운 관정을 개발해야만 한다. 본 연구에서는 지하수위 하강을 저감시키기 위한 방안으로 제내지 측에 인공함양우물을 설치하는 방법을 제안하였다. 창원시 강변여과 시설에 적용한 결과 인공함양우물의 최적 위치는 취수정으로부터 제내지 측으로 200m 지점에 위치하며, 함양량을 취수량의 $5\%$를 유지하는 것이 지하수위하강을 저감하기위한 효과적인 조건으로 판단되었다.

Excess pumping on the river bank filtration well causes the over drawdown in the protected area of bank, which may make many problems such as soil water contents, Pumping head in the irrigated land, and it needs more irrigation and development of the deeper irrigating well. In this study the installation of the artificial recharging well was suggested to reduce the excess draw down in the protected land. Artificial recharging wells were applied at the bank filtration site of Changwon city by using Visual-MODFLDW. The optimized conditions are calculated that the recharging well is located about loom apart from the pumping well, and the recharging rate is $5\%$ of the pumping yield.

키워드

참고문헌

  1. 한정상, 2000, 지하수환경과 오염, 박영사
  2. 한정상 외, 1999, 3차원 지하수 모델과 응용, 박영사
  3. 창원시, 2003, 창원시 강변여과수 개발관련 자료집
  4. 창원시, 2003, 방사형 집수정에 의한 강변여과수 개발타당성 조사 및 Pilot-Plant 조사연구
  5. 창원시, 2003, 강변지하수 개발에 대한 주변영향 조사연구
  6. 국립환경연구원, 1993, 독일의 지하수 관리
  7. 한국수자원공사, 1999, 지하수 함양 및 활용 증대방안연구
  8. Ray, Chittatamjan, 2003, Riverbank Filtation, Kluwer
  9. Sheets R.A., 2002, Lag times of Bank filtration at a well filed, Cincinnati, Ohio, USA, Journal of Hydrology, 266(2002), pp.161-174
  10. Saleh A, 2001, Ground water quality of the Nile west bank related to soil characteristics and geological setting, Journal of Arid Environments, 49(2001) pp.761-784