Cake Reduction Mechanism in Coagulation-Crossflow Microfiltration Process

Crossflow 방식 응집-정밀여과 공정의 케이크층 저감 메커니즘

  • 김수한 (한국과학기술원 건설 및 환경공학과) ;
  • 박희경 (한국과학기술원 건설 및 환경공학과)
  • Received : 2003.04.22
  • Accepted : 2003.07.01
  • Published : 2003.08.15

Abstract

Cake layer in crossflow microfiltration(CFMF) can be reduced by coagulation, enhancing membrane flux. This is because enlarging particle size by coagulation increases shear-induced diffusivity and the back-transport of rejected particles. However it is known that the enlarged particles are disaggregated by the shear force of the pump while passing through it. This study is to look at the disaggregation in relation with cake layer reducation. Kaolin and polysulfon hollow fiber microfilter are used for experiment. The reduction of cake resistance by coagulation is observed in a range of 17% to 53% at the various coagulation conditions. The particle size analysis results of the experiments show that aggregated particles in feed are completely disaggregated by pump but re-aggregation of particles occurs in membrane. This suggestes that the re-aggregation of particles is critical to cake reduction and flux enhancement, since the aggregated particles are completely broken. The mechanisms for re-aggregation in membrane are the same with those for coagulation in feed tank. Charge neutralization is better for CCFMF than sweep flocculation although it has two drawbacks in operation.

Keywords

References

  1. 조성호, 김수한, 박회경(2001) 입도분석을 이용한 Coagulation-microfiltration process의 해석, 상하수포학회지, 15(5), pp.385-397
  2. Bacchin P. Aimar P. and Sanchez V. (1996), Influence of Surface Interaction on Transfer during Colloid Ultrafiltration, Jourmd of Mnnbrone Science, 115, pp.49-63
  3. Dentel S. and Gossett J M. (1988), Mechanisms of Coagulation with Aluminum Salts., Journal of America Water Works Association, 80(4), pp. 187-198
  4. Eckstein E. C, Bailey D. G., and Shapiro A. H. (1977), Self-diffusion of Particles in Shear Flow of a Suspension, J. Fluid Mech., 79, pp.191-208
  5. Jaap H. J. M., Graaf V. D., Koning D. K, and Tang J (2000), Particle Size Analysis as a Tool for Performance Measurements in High Rate Effluent Filtration, Proceeding of 1st World Water Congress of the International Water Association (lWA), Paris, France, pp. 245-252
  6. Kim S., Cho S. H., and Park H. (2001a), Effects of Particle Size Distribution on the Cake Formation in Crossflow Microfiltration, Proceeding of 2nd World Water Congress (IWA), Berlin,Germany, p. 169
  7. Kim S., Cho S. H., and Park H. (2002), Reduction of Cake Layer by Re-aggregation in Coagulation-Crossflow Mierofiltration Process, Proceeding of IWA 3rd World Water Congress, p. 318, Melbourne, Austrailia, 2002. 4
  8. Kim S., Cho S. H., and Park H. (2002), Reduction of Cake Layer by Re-aggregation in Coagulation-Crossflow Microfiltration Process, Water Science and Technology: Water Supply, 2(5-6),pp. 329-336
  9. Kim J. S., Akeprathumchai S., and Wickramasinghe S. R. (2001b), Flocculation to Enhance Microfiltration, Jourmd of Membrane Science, 182,pp. 161-172
  10. Lee J-D., Lee. S.-H., Jo. M.-H., Park. P.-K, Lee. J-H. and KwakJ-W. (2000), Effect of Coagulation Conditions on Membrane Filtration Characteristics in Coagulation Microfiltration Process for Water Treatment, Environmental Science andTechnology, 34, pp.3780-3788
  11. Peuchot M. M. and, Aim B. R. (1992), Improvement of Crossflow Microfiltration Performances with Flocculation, Journal of Mnnbrone Science, 68, pp. 241-248
  12. Soffer Y., Ben A. R., Adin A. (2000). Membrane for water reuse: effect of pre-coagulation on fouling and selectivity, Water Science and Technology, 42(1-2), pp. 367-372