Abstract
In this study, the initial number of bacteria before ozone sterilizing shows 290 per $1m{\ell}$ in RUN 1 and RUN 2 equally, but the removal rate shows more than 50% in RUN 1, and 100% in RUN 2 respectively when ozone injection amount is $0.28mg/{\ell}$. It is regarded as a satisfactory result that E-coli concentration without ozone contact is 890, rapid removal effect of E-coli is observed in $0.28mg/{\ell}$ of ozone, and E-coli is removed perfectly in $0.84mg/{\ell}$ of ozone. It is thought that an excellent efficiency is obtained for vibrio alginolyticus because the initial number of bacteria before ozone contact is positive, but it is altered to negative after ozone contact. CODcr shows the tendency which is somewhat reduced as the ozone injection is increased, but the general effect is appeared not so much, and it is thought that the tendency is caused by the reason that sea water contains much salt which is estimated as a component of CODcr, therefore it is regarded that ozone contact has not an important effect on salinity. It is thought that the frequency of changing salt water in the fish preserve of a sliced raw fish restaurant can be reduced to under the standard because NTU of 7 days after sea water injection is 0.70 in the experiment of turbidity, hut more than 50% of turbidity removal efficiency is appeared at $0.28mg/{\ell}$ of ozone injection, and it shows 70% at $0.84mg/{\ell}$ of ozone injection in RUN 1 and RUN 2 commonly.