DOI QR코드

DOI QR Code

Determination of Fe(II) ion and Fe(III) ion by Chemiluminescence Method

화학발광법을 이용한 Fe(Ⅱ)이온과 Fe(Ⅲ)이온의 정량

  • Lee, Sang Hak (Department of Chemistry, Kyungpook National University) ;
  • Nam, Myeong Sik (Department of Chemistry, Kyungpook National University)
  • 이상학 (경북대학교 자연과학대학 화학과) ;
  • 남명식 (경북대학교 자연과학대학 화학과)
  • Published : 2002.12.20

Abstract

A method to determin Fe(II) and Fe(III) ion in aqueous solution by chemiluminescence method using a stopped flow system has been studied. The method is based on the increased chemiluminescence intensity with the addition of Fe(III) ion to a solution of lucigenin and hydrogen peroxide. The effects of KOH concentration, flow rate of reagents, $H_2O_2$ concentration and citric acid concentration used for the masking of Fe(II) ion on the chemilu-minescence intensity have been investigated. The calibration curve for total Fe was linear over the range from 1.0${\times}$$10^{-6}$ M to 1.0${\times}$$10^{-4}$M, coefficient of correlation was 0.996 and the detection limit was 1.0${\times}$$10^{-7}$M under the optimal exper-imental conditions of 4.0 M, 2.0 M, 3.5 mL/min for the concentration of $H_2O_2,$ KOH and flow rate of reagents, respec-tively. The calibration curve for Fe(Ⅲ) was linear over the range from 1.0${\times}$$10^{-6}$M to 1.0${\times}10^{-4}$ M, the coefficient of correlation was 0.997 and the detection limit was 5.0${\times}$$10^{-7}$M under the optimal experimental conditions.

정지흐름분석법을 이용하여 화학발광법으로 수용액 중의 Fe(II)와 Fe(III)을 분리 정량하는 방법에 대하여 연구하였다. 이 방법은 lucegenin과 $H_2O_2$ 혼합용액에 Fe(III)이온을 첨가하였을 때 화학발광의 세기가 증가하는 것을 기초로 하였다. KO H, $H_2O_2$ 및 Fe(III)의 가리움제로 이용한 citric acid의 농도와 시료의 주입속도가 화학발광의 세기에 미치는 영향을 조사하였다. 전체 철의 정량을 위하여 구한 [$H_2O_2$], [KOH] 및 흐름속도의 죄적조건은 각각 4.0M, 2.0M, 및 3.5mL/min 이었고, 이러한 최적조건 하에서 얻은 검정곡선에서 직선성이 성립하는 범위는 1.0${\times}10^{-6}$M에 서 1.0${\times}10^{-4}$M이었고, 상관계수는 0.996, 검출한계는 1.0${\times}10^{-7}$M이었다. Fe(III)이온의 정량을 위하여 구한 [$H_2O_2$], [KOH], [citric acid] 및 흐름속도의 최적조건은 각각 4.0M, 2.0M, 0.01M 및 3.5mL/min이었고 이러한 최적조건 하에서 얻은 검정곡선에서 직선성이 성립하는 범위는 1.0${\times}10^{-6}$M에서 1.0${\times}10^{-4}$M이었고, 상관관계수는 0.997, 검출한계는 5.0${\times}10^{-7}$M이었다.

Keywords

References

  1. Encyclopedia of Analytical Science; Townshend, A.,Ed.; Academic Press: New York, U. S. A., 1995, 4,2369.
  2. Patruta, S. I.; Edlinger, R.; Sunder-Plassmann, G.; Horl,W. H. J. Am. Soc. Nephrol. 1998, 9, 655.
  3. Uchida, T. Int. J. Hematol. 1995, 62, 193. https://doi.org/10.1016/0925-5710(95)00419-X
  4. Mulero, V.; Brock, J. H. Blood 1999, 94, 2383.
  5. Shears, G. E.; Neale, R. J.; Ledward, D. A. Br. J. Nutr.1989, 61, 573. https://doi.org/10.1079/BJN19890144
  6. Kochana, J.; Parczewski, A. Chem. Anal. 1997, 42, 411.
  7. Kosse, J. S.; Yeung, A. C.; Gil, A. I.; Miller, D. D.Food Chem. 2001, 75, 371. https://doi.org/10.1016/S0308-8146(01)00215-1
  8. Damkroger, G. Fresenius J. Anal. Chem. 1997, 357, 817. https://doi.org/10.1007/s002160050255
  9. Fernandez, P. L.; Pablos, F.; Martin, M. J.; Gonzalez,A. G. Food Chem. 2002, 76, 483. https://doi.org/10.1016/S0308-8146(01)00312-0
  10. Budic, B. Fresenius J. Anal. Chem. 2000, 368, 371. https://doi.org/10.1007/s002160000468
  11. Budic, B.; Klemenc, S. Spectrochim. Acta 2000, 55B, 11.
  12. Watanabe, M.; Narukawa, A. Analyst 2000, 125, 1189. https://doi.org/10.1039/b001608j
  13. Ueoka, S.; Furukawa, J.; Nakanishi, T. M. J. Radioanal.Nucl. Chem. 2001, 249, 475. https://doi.org/10.1023/A:1013263830235
  14. Favaro, D. I. T.; Maihara, V. A.; Mafra, D.; Souza, S.A.; Vasconcellos, M. B. A.; Cordeiro, M. B. C.; Cozzolino,S. M. F. J. Radioanal. Nucl. Chem. 2000, 244, 241. https://doi.org/10.1023/A:1006769727407
  15. Dutta, R. K.; Acharya, R. N.; Chakravortty, V.; Nair, A.G. C.; Reddy, A. V. R.; Chintalapudi, S. N.; Manohar,S. B. J. Radioanal. Nucl. Chem. 1998, 237, 91. https://doi.org/10.1007/BF02386668
  16. Duan, T.; Chen, H.; Zeng, X. J. Anal. At. Spectrom.2002, 17, 410. https://doi.org/10.1039/b109660p
  17. Chen, H. H.; Beauchemin, D. J. Anal. At. Spectrom.2001, 16, 1356. https://doi.org/10.1039/b106653f
  18. Harrington, C. F.; Elahi, S.; Merson, S. A.; Ponnampalavanar,P. Anal. Chem. 2001, 73, 4422. https://doi.org/10.1021/ac010279h
  19. Martino, F. A. R.; Sanchez, M. L. F.; Sanz-Medel, A.Anal. Chim. Acta 2001, 442, 191. https://doi.org/10.1016/S0003-2670(01)01170-9
  20. Rose, A. L.; Waite, T. D. Anal. Chem. 2001, 73, 5909. https://doi.org/10.1021/ac015547q
  21. Alapont A. G.; Zamora, L. L.; Calatayud, J. M. J.Pharm. Biomed. Anal. 1999, 21, 311. https://doi.org/10.1016/S0731-7085(99)00124-7
  22. Bowie, A. R.; Achterberg, E. P.; Mantoura, R. F. C.;Worsfold, P. J. Anal. Chim. Acta 1998, 361, 189. https://doi.org/10.1016/S0003-2670(98)00015-4
  23. Encyclopedia of Analytical Science; Townshend, A.,Ed.; Academic Press: New York, U. S. A., 1995, 1, 608.
  24. Weber, A. J.; Grayeski, M. L. Anal. Chem. 1987, 59,1452. https://doi.org/10.1021/ac00137a017
  25. Robarrds, K.; Worsfold, P. J. Anal. Chim. Acta 1992,266, 173.
  26. Luminescence Biotechnology: Instrumentation andApplications; Dyke, K. V.; Dyke, C. V.; Woodfork, K.,Ed.; CRC Press: New York, U. S. A., 2002.