In Vitro Test of Seiong Pediatric Ventricular Assist Device

소아용 보조인공심장의 모의순환 실험에 관한 연구

  • 권혁남 (세종병원 의학연구소 의공학연구실) ;
  • 박표원 (세종심장병연구소)
  • Published : 1991.03.01

Abstract

Ventricular assist device(VAD) has been clinically applied as a temporary circulatory sup- porting system in the patients with severe heart failure, but small sized VAD for infant is not available. The purpose of tilis paper is to introdIAce small sized VAD and presents the result of in vitro test. Sejong VAD is diaphragmatic type of pneumatic pump and stroke volume is 11cc. Cardiac outputs of the Sejong VAD were measured by overflow tank under variable conditions of driving parameters. The cardiac output was 1.3 1/min at the heart rate of 120 per minute, left atrial pressure of $15cmH_2O$, percent systole of 43%, driving pressure of 240 mmHg, vacuum pressure of -40 mmHg, and mean aortic pressure of 70 mmHg. No mechanical problem was developed during the continuous in vitro test for 3 months.

Keywords

References

  1. The Journal of Sejong General Hospital v.4 no.2 Experimental Study of artificial heart in sheep and calves : preliminary report Park,P.W.;Lee,Y.K.(et al.)
  2. J. Thorac. Cardiovasc. Surg. v.37 Development and evaluation of ventricular assist blood pump to salvage patients with propound heart failure Takano,H.;Taenaka,Y.(et al.)
  3. 日本體外循環技術硏究會第 12回大會別冊 人工心臟と 補助心臟 福增廣幸
  4. Artificial heart v.2 Clinical evaluation of left ventricular assist device in six cases Shiono,M.;Hasegawa,T.(et al.)
  5. Arti-fical heart v.2 Left ventricular assist device : Experimental and study Okada,M.;Kuboda,M.(et al.)
  6. 人工臟器 v.12 no.3 完全置換型人工心臟 岩谷文夫;星野俊一;本多憲俱
  7. Artificial heart v.1 Total artificial heart research in Czechoslovakia : Patho physiological evaluation of long term experiments performed from 1979 to 1985 Vasku,J.
  8. 人工臟器工學 渥美和彦 他
  9. Artificial hear & assist device(The 3rd Inter. Symposium Abstracts):1 Development of artificial heart with left and right ventricles using a linear pulse motor Yamada,H.;Sato,Y.(et al.)
  10. 人工臟器 v.19 no.1 振子式レソズ型人工心臟の試作 福氷信太郞 他
  11. Artificial heart v.2 Pulsatile veno-arterial bypass with a pusher plate pump for profound biventricular failure Irie,H.;Murakami,t.(et al.)
  12. Jpn. J. Artif. Organs v.14 no.3 Hydrodynamic performances of Tri-leaflet polyurethane valve Noda,H.;Umezu,M.(et al.)
  13. Jpn. J. Artif. Organs v.18 no.2 Development of artificial valve(Jelly fish valve) for artificial heart biood pump with a new concept Inachi,K.;Chinzei,T.(et al.)
  14. Jpn. J. Artif. Organs v.19 no.1 Development of Plastic ball valve builtin connector for artificial heart Nagase,T.;Yoda,R.(et al.)