Abstract
This paper proposes a detection method for mechanically stuck control rod drive mechanisms (CRDMs) in the nuclear reactor. From an electrical viewpoint, a coil of an electro-mechanical CRDM is modelled as an R-L circuit with time-varying inductance. The inductance of the coil is estimated from the measured voltage and current by using the least square method. Numerical experiments are carried out to illustrate the proposed method.