Proceedings of the KSME Conference (대한기계학회:학술대회논문집)
- 2001.11b
- /
- Pages.241-247
- /
- 2001
Effects of Rib Geometries on the Friction Factors and Heat Transfer in the Channel
거칠기 형상이 마찰 계수와 열전달에 미치는 영향
Abstract
A comparison of fully developed heat transfer and friction factor characteristics has been made in rectangular ducts with ones roughened by five different shapes. The effects of rib shape geometries and Reynolds number are examined. The rib height-to-duct hydraulic diameter, pitch-to-height ratio, and aspect ratio of channel width to height are fixed at e/De=0.0476, P/e=8, and W/H=2.33, respectively. To understand the mechanisms of the heat transfer enhancements, the measurements of the friction factors are also conducted in the smooth and rough channels. The data indicates that the triangular type rib has a substantially higher heat transfer performance than any other ones in the range we studied.
Keywords