• Title/Summary/Keyword: zero-span tension

Search Result 3, Processing Time 0.018 seconds

Development of Test Device for Response to Structural Behavior of Constrained that can Apply Zero-Span Tension Conditions (무절점 인장응력 조건의 적용이 가능한 구속형 구조물 균열 거동 대응 성능 시험 장치 개발)

  • An, Hyun-Ho;Choi, Young-Hyun;Park, Wan-Goo;Kim, Young-Keun;Oh, Sang-Keun;Choi, Su-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.214-215
    • /
    • 2021
  • The existing evaluation method could not apply the effect of zero span tension generated in the waterproofing layer attached to the surface of the structure at the moment of cracking as the waterproofing layer was constructed in the state where the cracks were formed. The test apparatus developed through this study is expected to be able to conduct tests closer to the environment occurring in actual structures as it is possible to simultaneously create a pressurized (constrained) condition and an environment for zero span tension.

  • PDF

Modeling and Analysis of a Pendulum Dancer in Industrial Converting Machines (산업용 컨버팅 머신의 펜듈럼 덴서 모델링 및 해석)

  • Kang, Hyun-Kyoo;Shin, Kee-Hyun;Kim, Sang-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.5
    • /
    • pp.482-488
    • /
    • 2009
  • Dancer system is typically used equipment for attenuation of tension disturbances. In industrial converting machines, a composite type of dancer system is applied which is mixture of active and passive dancer. It includes feedback position control loop of roll with pendulum dancer and its characteristics is different from passive and active one. In this paper, a mathematical model of the pendulum dancer was derived including PI position feedback controller and it was analyzed by using a pole-zero map and bode plot under various conditions. It was found out that velocity, length of span and inertia were associated with the performance of regulation. It was suggested that the length of upstream span should be greater than that of the downstream and the inertia should be smaller for improvement of the performance. The results can be used for design guidelines of the industrial dancer system.

A Fundamental Study on Induction Technology of Separation Behavior Using Two-sided Adhesion of Joint of Composites Waterproofing System (시트-도막 복합방수공법의 접합부 2면 접착을 통한 분리거동 유도 기술에 관한 기초적 연구)

  • Park, Jin-Sang;Lee, Tae-Yang;Kim, Dong-Bum;Park, Wan-Goo;Heo, Neung-Hoe;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.3
    • /
    • pp.212-219
    • /
    • 2015
  • This study focuses evaluating the efficiency and performance evaluation of composite type sheet-membrane waterproofing method that utilizes a separation behavior inducement system designed to resolve the chronic problems of disintegration and damage of overlap areas of waterproofing layers. As the result of the test, the tensile strength value was at 13.8N/mm and elongation rate at 587% for the separation behavior inducement type specimen, and the compared specimens had 14.2N/mm for tensile strength and 335% for elongation rate. For the separation behavior adhesion method specimen, when tensile stress or displacement occurred, the Zero-Span tension occurrence did not follow, which resulted in that the bottom sheet layer and the top membrane layer did not simultaneously becoming damaged. When undergoing the top and bottom layers were separated through separation behavior due to lack of flexibility, the bottom layer began to damage at the primary stage, and with the allowed boundary the upper membrane layer began to display flexibility and showed continuous displaced resulting in secondary phase damaging.