• Title/Summary/Keyword: zeolite column

Search Result 66, Processing Time 0.027 seconds

Scalants removal from synthetic RO brine using natural zeolite (막증류 공정의 전처리 공정으로서 천연 제올라이트 컬럼 적용)

  • Jeong, Seongpil;Chung, Hayoon;Yoon, Teakgeun;Lee, Seockheon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.279-284
    • /
    • 2016
  • Membrane distillation (MD) is the thermally driven water separation process based on the vapor pressure difference across the membrane. In order to increase the water recovery of the conventional RO process, the additional MD-PRO pocess was suggested. In this study, the syntheric RO brine was used as a feed solution of the MD process. Due to the high salinity of the RO brine, the MD membrane could be fouled by the scalants. In order to mitigate the scaling on the MD membrane surface, the pre-treatment process using the column filled by natural zeolite was applied. The roughing filter was installed between the pre-treatment process and MD system in order to prevent possible particulate fouling by the debries of the natural zeolite. Moreover, in order to enhance the CEC of the natural zeolite, the NaCl soaking was conducted. The flux and electronic conductivity were monitored under given experimental conditions. And the membrane morphology and the chemical compositions were analyzed by using the SEM-EDX.

Heavy matal removal in leaching water from the region buried tungsten tailing (중석광 폐재광미의 매립지에서 나오는 침출수 중의 중금속 제거)

  • Lee, Dong-Hoon;Oh, Sae-Gang;Choi, Choong-Lyeal;Park, Man;Choi, Jyung
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.3
    • /
    • pp.218-222
    • /
    • 2000
  • Wasted${\cdot}$rested mine areas give lots of effect on around-environmental changes after mining development. Leaching water at reclaimed land has been eluted from the solid components through physical, chemical, biological procedures by waters percolated through reclaimed site. The element analysis of waste tungsten ore tailing, leaching water analysis and removal of heavy metal by zeolite were performed to investigate the influent of acid rain on the released contents of H. M. The heavy metal contents in leaching water were determined to be As $1.21\;{\sim}\;1.54\;ppm$, Pb $0.11\;{\sim}\;0.15\;ppm$ and $SO_4\;^{2-}$ was $302\;{\sim}\;378ppm$. As deionized water and simulated acid rain (pH 3,4) were percolated through columns packed tungsten ore tailing, the amount of Mn, Na, Ca which were dissolved by pH4 solution was higher than those by distilled water. However, W and Mo were eluted easily by high pH solution. The change of heavy metal concentration by column experiment packed zeolite was effective a little because heavy metals were adsorved much more by zeolite.

  • PDF

Simultaneous Removal of Cd & Cr(VI) by Fe-loaded Zeolite in Column System (Fe-loaded zeolite를 이용한 칼럼 실험에서의 Cd & Cr(VI) 동시제거 반응성 평가)

  • Lee Ah-Ra;Lee Seung-Hak;Park Jun-Boum
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.1
    • /
    • pp.14-22
    • /
    • 2006
  • Laboratory column experiment for simultaneous removal of Cd and Cr(VI) were conducted using newly developed material of Fe-loaded zeolite having both reduction ability and sorption capacity. The solution containing Cd and Cr(VI) was injected into the column and the breakthrough curves (BTCs) for the contaminants were observed at the effluent port. Cd breakthrough was not initialized until Cr(VI) breakthrough was completed. Therefore it could be concluded that overall efficiency of Fe-loaded zeolite should be determined by the reactivity for Cr(VI). The relative concentration of Cr(VI) BTC increased to the unit value while initial breakthrough was delayed and the propagation of breakthrough was slowed. In order to quantitatively describe the shape of Cr(VI) BTC, new parameters of ${\alpha}\;and\;{\beta}$ designated to be shape parameters, were defined and applied in contaminant transport concentration. These parameters were employed to represent the degree of initial breakthrough delay and the degree of breakthrough propagation, respectively. As initial contaminant concentration increased, ${\alpha}$ decreased, which indicated the delay of BTC's initiation. And as initial contaminant flow rate increased, ${\beta}$ decreased, which represented the faster propagation of the BTC. From these results, Fe-loaded zeolite was found to be an effective reactive material for PRBs against heavy metals having different ionic forms in groundwater. And it could be expected that as groundwater flows faster, the propagation of breakthrough would be faster and as contaminant concentration is higher, the initial point of breakthrough would appear earlier.

Comparison of Pollutant Removal Efficiency in Road Sediment with Media Using Filter Separator (필터 분리기를 이용한 여재별 도로퇴적물의 오염물질 제거효율 비교)

  • Bang, Ki-Woong;Lee, Jun-Ho;Choi, Chang-Su;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.332-340
    • /
    • 2007
  • Storm runoff from road contains significant loads of particulate and dissolved solids, organic constituents and metal elements. Micro particle is important when considering pollution mitigation because pollutant metal and organics have similar behavior with particles. The objective of this research is to evaluate the hydrodynamic filter separator performance for road storm runoff treatment. A various types of media such as perlite, granular activated carbon, zeolite were used for column test packing media and filter separator, and to determine the removal efficiency with various surface loading rate. As the results of column test, the highest SS removal efficiency was using mixed media(granular activated carbon, zeolite and perlite), and granular activated carbon mixed with zeolite has higher heavy metal removal efficiency than perlite. In laboratory scale hydrodynamic filter separator study, the operation ranges of surface loading rates were from 192 to 1,469 $m^3/m^2/day$. The estimated overall removal efficiencies of hydrodynamic filter separator for typical storm runoff were SS 48.1%, BOD 31.9%, COD 32.6%, TN 15.5%, and TP 17.3%, respectively. For the case of heavy metals, overall removal efficiencies were Fe 26.0%, Cu 19.4%, Cr 25.7, Zn 16.6%, and Pb 15.0%, respectively. The most appropriate medium for hydrodynamic filter separator was perlite mixed with granular activated carbon to treatment of road storm runoff.

A Sutdy on Cesium Adorption by Domedtic Zeolite (국산 불석의 세슘 흡착 특성에 관한 연구)

  • 이원근
    • Journal of Surface Science and Engineering
    • /
    • v.21 no.1
    • /
    • pp.47-52
    • /
    • 1988
  • The purpose of th this study was to determine an adsorption capaty of cesium by domestic zeolite, clinoptilolite, which has adsorption selectivity and resistence to radiolytic degradation, and to find the operation of column packed natural or Na cinoptiloite. The exchange capacity of cesium was 0, 875 m eq-per gram of clinopilolite. Na clinoptilolite was mire effective for cesium removal than naturl clioptilolite. Then, the results show that the domestic cilnoptilolite activated with sodium hydroxide colud be applicable for removal of cesium from liquid radwastes.

  • PDF

Anodic Stripping Differential Pulse Voltammetric Determination of Trace Amounts of Lead after Preconcentration of Its Complex with 2-(5-Bromo-2-pyridylazo)-5-diethylaminophenol onto Natural Analcime Zeolite by Column Method

  • Taher, Mohammad Ali;Mostafavi, Ali;Afzali, Darush;Rezaeipour, Ebrahim
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.8
    • /
    • pp.1125-1129
    • /
    • 2004
  • This work assesses the potential of natural Analcime Zeolite as an adsorbent for preconcentration of lead (II) traces. Lead is quantitatively retained on 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol by column method with Analcime in the pH range of 5-6.5 and 2 mL $min^{?1}$ flow rate. Lead was removed from the column with 10.0 mL of 4 M hydrochloric acid and was determined by anodic stripping differential pulse voltammetry. 0.5ppb detection limit was obtained and linear dynamic range was 3 to $1.2{\times}10^5$ ppb in final solution with correlation coefficient of 0.999 and relative standard deviation of ${\pm}$ 1.2% (for eight replicate determination of 2.5 ${\mu}g\;mL^{?1}$ of lead). Various parameters such as the effect of pH, flow rate, instrumental conditions and interferences of some ions on the determination of lead have been studied in detail for optimization of conditions. The method was successfully applied for determination of lead in various samples.

Ammonia Nitrogen Removal by Cation Exchange Resin (양이온 교환수지에 의한 암모니아성 질소 제거)

  • 이동환;이민규
    • Journal of Environmental Science International
    • /
    • v.11 no.3
    • /
    • pp.263-269
    • /
    • 2002
  • This study was conducted to know the removal characteristics of ammonia nitrogen by commercially available cation exchange resins. Eight acidic cation exchange resins were investigated in batch reactors. Among them, the most effective resin for ammonia removal in solution was PK228, which was a strong acidic resin of $Na^{+}$ type. PK228 was compared with activated carbon and natural zeolite. The effects of cation exchange capacity, ammonia concentration, resin amount, temperature and pH on ammonia removal by PK228 were investigated in batch reactor, and the effect of effluent velocity in continuous column reactor. Strong acidic resins of porous type were more effective than week acidic resins or gel type resins for ammonia removal in solution. PK228 was more effective than activated carbon and natural zeolite for ammonia removal in batch reactor. With increasing initial ammonia concentration, the amount of ammonia removed by PK228 increased, but the proportion of removed ammonia to initial ammonia concentration decreased. The effect or temperature on ammonia removal by PK228 was very slight. The ammonia removal to acidic solution was more effective than that at basic solution. With decreasing effluent velocity of solution through column, breakthrough point extended, and ammonia removal capacity increased.d.

Investigation of Cryogenic Breakthrough Curve Measurement System at 77 K for Hydrogen Isotopologue Separation (수소 동위원소 분리를 위한 77 K 극저온 파과 곡선 측정 시스템 제작)

  • Kim, Suhwan;Oh, Hyunchul
    • Korean Journal of Materials Research
    • /
    • v.32 no.1
    • /
    • pp.36-43
    • /
    • 2022
  • Breakthrough analysis has widely been explored for the dynamic separation of gaseous mixtures in porous materials. In general, breakthrough experiments measure the components of a flowing gas when a gaseous mixture is injected into a column filled with an adsorbent material. In this paper, we report on the design and fabrication of a breakthrough curve measurement device to study the dynamic adsorptive separation of hydrogen isotopologues in porous materials. Using the designed system, an experiment was conducted involving a 1:1 mixture of hydrogen and deuterium passed through a column filled with zeolite 13X (1 g). At room temperature, both hydrogen and deuterium were adsorbed in negligible amounts; however, at a temperature of 77 K, deuterium was preferentially adsorbed over hydrogen. The selectivity was different from that in the existing literature due to the different sample shapes, measurement methods, and column structures, but was at a similar level to that of cryogenic distillation (1.5).

WASTEWATER TREATMENT USING COMBINATION OF MBR EQUIPPED WITH NON-WOVEN FABRIC FILTER AND OYSTER-ZEOLITE COLUMN

  • Jung, Yoo-Jin;Koh, Hyun-Woong;Shin, Won-Tae;Sung, Nak-Chang
    • Environmental Engineering Research
    • /
    • v.10 no.5
    • /
    • pp.247-256
    • /
    • 2005
  • A combination of the submerged membrane activated-sludge bioreactor(SMABR) equipped with non-woven fabric filter and oyster-zeolite (OZ) packed-bed adsorption column was studied to evaluate the advanced tertiary treatment of nitrogen and phosphorous. The non-woven filter module was submerged in the MBR and aeration was operated intermittently for an optimal wastewater treatment performance. Artificial wastewater with $COD_{Cr}$ of 220 mg/L, total nitrogen (T-N) of 45 mg/L, and total phosphorous (T-P) of 6 mg/L was used in this study. MLSS was maintained about $4,000\;{\sim}\;5,000\;mg/L$ throughout the experiments. The experiments were performed for 100-day with periodic non-woven filter washing. The results showed that $COD_{Cr}$ could be effectively removed in SMABR alone with over 94% removal efficiency. However, T-N and T-P removal efficiency was slightly lower than expected with SMABR alone. The permeate from SMABR was then passed through the OZ column for tertiary nutrients removal. The final effluent analysis confirmed that nutrients could be additionally removed resulting in over 87% and 46% removal efficiencies for T-N and T-P, respectively. The results of this study suggest that the waste oyster-shell can be effectively reclaimed as an adsorbent in advanced tertiary wastewater treatment processes in combination with SMABR equipped with non-woven fabric filter.

CO2 PSA Process using Double-Layered Adsorption Column (이단 적층 흡착탑을 이용한 CO2 PSA 공정)

  • Lee, Hwaung;Choi, Jae-Wook;Song, Hyung Keun;Na, Byung-Ki
    • Clean Technology
    • /
    • v.7 no.1
    • /
    • pp.51-63
    • /
    • 2001
  • In this study, PSA, known as the most economic process, was used to recover $CO_2$ from the power-plant flue gas. Activated carbon and zeolite molecular sieve 13X were used as adsorbent. Activated carbon has been deemed inadequated adsorbent for separating $CO_2$ from the flue gas. However, highly concentrated $CO_2$ could be obtained as a product on the activated carbon adsorbent using the new operating cycle modifying the rinse step. Also, the recovery of $CO_2$ was improved using double-layered adsorption column packed with the activated carbon and the zeolite 13X simultaneously. Adsorption column was filled with the activated carbon in the feed-end side, and the zeolite 13X in the product-end side. The recovery of $CO_2$ increased about 40% with only 25% zeolite, and increased 67% with 50% zeolite at the experimental conditions of 13% $CO_2$ concentration, 10 SLPM flow rate and 2.2 atm adsorption pressure.

  • PDF