• Title/Summary/Keyword: x-y table

Search Result 326, Processing Time 0.03 seconds

A comparative study for resolution and density of chest imaging using film/screen, CR and DR (X-ray 흉부영상 FIlm/Screen, CR, DR Resolution과 Density 비교평가)

  • An, Byeong-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.25-30
    • /
    • 2010
  • The objective of this study was to compare the resolution and density appropriate to diagnosis in chest PA radiography. In comparing the resolution, we radiographed with conventional radiography, computed radiography(CR) and digital radiography(DR) using the linear resolution phantom(Nuclear Associates-Carle Place. N.Y.). 2 radiologists and 3 radiological technologists read the resolution value by the blind test. DR, conventional radiography and CR measured 3.95, 3.58, 3.48 resolution value respectively. In analysing the density, we chose the fifty normal chest CR and DR and conventional film. We estimated the density using by densitometer(X-rite company-Model 301) in seven regions(lung field, lung field margine, mediastinum I, mediastinum II, heart shadow I, heart shadow II, diaphragm) of chest film. We adapted to analysis the Japanese chest X-ray evaluating method and table. It was scored 0(farthest density value) to 2(nearest density value). DR scored 2 at mediastinum I, mediastinum II, heart shadow I, heart shadow II and diaphragm. On the contrary with, CR scored 2 at lung field and lung field margine. Consequently, DR superior than CR and conventional radiography film compairing density and resolution. It was due to small pixel size and post processing algorithm with digital radiography.

Compressed-sensing (CS)-based Image Deblurring Scheme with a Total Variation Regularization Penalty for Improving Image Characteristics in Digital Tomosynthesis (DTS) (디지털 단층합성 X-선 영상의 화질개선을 위한 TV-압축센싱 기반 영상복원기법 연구)

  • Je, Uikyu;Kim, Kyuseok;Cho, Hyosung;Kim, Guna;Park, Soyoung;Lim, Hyunwoo;Park, Chulkyu;Park, Yeonok
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • In this work, we considered a compressed-sensing (CS)-based image deblurring scheme with a total-variation (TV) regularization penalty for improving image characteristics in digital tomosynthesis (DTS). We implemented the proposed image deblurring algorithm and performed a systematic simulation to demonstrate its viability. We also performed an experiment by using a table-top setup which consists of an x-ray tube operated at $90kV_p$, 6 mAs and a CMOS-type flat-panel detector having a $198-{\mu}m$ pixel resolution. In the both simulation and experiment, 51 projection images were taken with a tomographic angle range of ${\theta}=60^{\circ}$ and an angle step of ${\Delta}{\theta}=1.2^{\circ}$ and then deblurred by using the proposed deblurring algorithm before performing the common filtered-backprojection (FBP)-based DTS reconstruction. According to our results, the image sharpness of the recovered x-ray images and the reconstructed DTS images were significantly improved and the cross-plane spatial resolution in DTS was also improved by a factor of about 1.4. Thus the proposed deblurring scheme appears to be effective for the blurring problems in both conventional radiography and DTS and is applicable to improve the present image characteristics.

Image Quality Evaluation of Medical Image Enhancement Parameters in the Digital Radiography System (디지털 방사선시스템에서 영상증강 파라미터의 영상특성 평가)

  • Kim, Chang-Soo;Kang, Se-Sik;Ko, Seong-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.329-335
    • /
    • 2010
  • Digital imaging detectors can use a variety of detection materials to convert X-ray radiation either to light or directly to electron charge. Many detectors such as amorphous silicon flat panels, CCDs, and CMOS photodiode arrays incorporate a scintillator screen to convert x-ray to light. The digital radiography systems based on semiconductor detectors, commonly referred to as flat panel detectors, are gaining popularity in the clinical & hospital. The X-ray detectors are described between a-Silicon based indirect type and a-Selenium based direct type. The DRS of detectors is used to convert the x-ray to electron hole pairs. Image processing is described by specific image features: Latitude compression, Contrast enhancement, Edge enhancement, Look up table, Noise suppression. The image features are tuned independently. The final enhancement result is a combination of all image features. The parameters are altered by using specific image features in the different several hospitals. The image in a radiological report consists of two image evaluation processes: Clinical image parameters and MTF is a descriptor of the spatial resolution of a digital imaging system. We used the edge test phantom and exposure procedure described in the IEC 61267 to obtain an edge spread function from which the MTF is calculated. We can compare image in the processing parameters to change between original and processed image data. The angle of the edge with respect to the axes of detector was varied in order to determine the MTF as a function of direction. Each MTF is integrated within the spatial resolution interval of 1.35-11.70 cycles/mm at the 50% MTF point. Each image enhancement parameters consists of edge, frequency, contrast, LUT, noise, sensitometry curve, threshold level, windows. The digital device is also shown to have good uniformity of MTF and image parameters across its modality. The measurements reported here represent a comprehensive evaluation of digital radiography system designed for use in the DRS. The results indicate that the parameter enables very good image quality in the digital radiography. Of course, the quality of image from a parameter is determined by other digital devices in addition to the proper clinical image.

A Study on the Accuracy and Convenience of Imaging Method Using Support Device in Knee Joint Lateral Radiography (슬관절의 측면 방사선 촬영에서 보조기구를 이용한 검사방법의 정확성과 편의성에 대한 연구)

  • Uhm, Soyeong;Cho, Yongkeun;Kang, Sungjin
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.253-262
    • /
    • 2017
  • In lateral projection imaging method of knee joint, a method that adjusts the incidence angle of central X-ray toward the head side to $5{\sim}7^{\circ}$ in true lateral position which is existing recommended is called imaging method A, Method of imaging the central X-ray perpendicular to the horizontal plane of the examination table toward the knee is called imaging method B, and a method in which the central X-ray is perpendicularly applied to the joints while the lateral side of the distal tibia is compensated by radiolucent materials is called as method C. After tests each imaging method to classified study subject respectively, the joint space distance and the distance between lateral and medial condyle of femur were measured and compared as the quantitative index from the three imaging methods. In addition, the convenience of each imaging method was confirmed through questionnaires to practician. According to the result of the quantitative index, there is no statistically significant difference in imaging method A and C(p>0.05). However, imaging method B showed a significant difference in both A and C(p<0.05). As a result of evaluating the convenience of the imaging method, imaging method A was relatively assessed lower in all items than imaging methods B and C, and as a small difference, imaging method B is assessed higher than C. In this study suggested new knee joint lateral projection imaging method, by using a simple support device, could describe joint space as not much different as existing recommended method without some complex process, and could increase convenience of the practician in the process of the imaging.

A Development of a Robotic Switch Board System for Main Distributing Frames (주배선반용 로봇 스위치 보드 시스템의 개발)

  • Sung, Young-Whee;Chung, Hae;Yi, Soo-Yeong;Ahn, Hee-Wook
    • The Journal of Korea Robotics Society
    • /
    • v.4 no.2
    • /
    • pp.155-162
    • /
    • 2009
  • A main distributing frame(MDF) is an interface unit that is used to connect office equipment cables in a telephone company to subscriber cables. Until now, there is no automated switching system for MDFs in Korea. Manual handling of an MDF has some drawbacks; It is time-consuming, very cumbersome, and expensive. It also makes maintenance hard. An automated main distributing frame system is proposed and commercialized in Japan. In that system, a robot gripper inserts connecting pins into the cross point holes of a matrix board, which reveals several disadvantages in the aspects of space, maintenance, fault tolerance, and economical efficiency. This paper describes a newly developed robotic switch board system for MDFs. In the developed system, switches are placed at the cross point of a matrix board. There is one robot in between two switch units, so one robot deals with two switch units. In the system, positioning the robot, opening and closing switches can be done by using only a pair of motors and a pair of solenoids. The newly developed system is compact in size, reduces cost, and shows high reliability.

  • PDF

The realtime measurement of burrs on sheet metal using the semiconductor laser (반도체 레이저를 이용한 박판 버의 실시간 측정)

  • 홍남표;신홍규;김헌영;김병희
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10a
    • /
    • pp.107-110
    • /
    • 2003
  • The sheet metal shearing process is normally used in the precision elements such as semi-conductor components. In precision elements, burrs usually reduce the quality of machined parts and cause interference, jamming and misalignment during assembly procedures and because of their sharpness, they can be safety hazard to personnel. Furthermore, not only burrs are hard to predict and avoid, but also deburring, the process of removing burrs, is time-consuming and costly. In order to get the burr-free parts, therefore, we developed the precise burr measuring system using the laser. Using the X-Y precious table, we used vertical measuring method. Through the laser measurement system, we gain the minute analog signal, so this signal was amplified by the electric circuit. Finally, we gained the realtime burr data using A/D converter, PC. By introducing the novel laser measuring method which employing vertical measurement mechanism, we could get fast and precious burr data. Through the experiments, the accuracy of the developed system is proved. The burr height measured during the punching process can be used for automatic deburring and in-situ aligning.

  • PDF

The Control of SFFS in the Office Environments and It's Integration

  • Kim, Jung-Su;Lee, Min-Cheol;Lee, Won-Hee;Kim, Dong-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2164-2169
    • /
    • 2005
  • SFFS(Solid Freeform Fabrication System) can quickly makes models and prototype parts from 3D computer-aided design (CAD) data. Three dimensional printing(3DP) is a kind of the solid freeform fabrication. The 3DP process slices the modeling data into the 50-200um along to z axis. And we pile the powder and make the manufactures. A manufacture is made by the SFFS has the precision of the 50um. Therefore the x-y table of SFFS to move a printhead must be the system that has a high speed and accuracy. So we proposed the SMCSPO algorithm for SFFS. The major contribution is the design of a robust observer for estimating the state and the perturbation of the timing belt system, which is combined with a robust controller. The control performance of the proposed algorithm is compared with PD control by the simulation and the experiment. The control algorithm of the SFFS is presented in the office environment. The system between control system and printhead for the SFFS is also integrated

  • PDF

Experimental Study on the Dynamic Characteristics of Porcelain Surge Arrestor Considering the Variation of Cable's Tension and Arrestor's Stiffness (케이블 장력 및 피뢰기의 강성 변화를 고려한 애자형 피뢰기의 동특성 시험 연구)

  • Jang, Jung Bum;Hwang, Kyeong Min;Yun, Kwan Hee
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.253-259
    • /
    • 2014
  • Porcelain surge arrestor is very vulnerable to earthquake but there is very few information on its dynamic characteristics which are necessary to the seismic design. Therefore, the dynamic characteristics of the porcelain surge arrestor are evaluated considering the variation of its cable tension and stiffness by shaking table test. The test results show that the first natural frequencies are 5.3 Hz and 5.2 Hz in the horizontal x- and y-axis directions, respectively, and higher than 30 Hz in the vertical z-axis direction, respectively. The installation of cable on the surge arrestor reduces the horizontal natural frequencies due to the constraint effect of the cable but cable tension has no effect on the natural frequency. Also, the natural frequency is proportional to the stiffness of the surge arrestor. This test result will be used for the seismic design and seismic capacity assessment of domestic substations and contribute to the stability of the electric power supply under earthquake event.

Burr Control in Meso-Punching Process

  • Shin Hong Gue;Shin Yong Seung;Kim Byeong Hee;Kim Heon Young
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.968-975
    • /
    • 2005
  • The shearing process for the sheet metal is normally used in the precision elements such as semi-conductor components. In these precision elements, the burr formation brings a bad effect on the system assembly and demands the additional de-burring process, so this imposes high cost on manufacturing. In this paper, we have developed the in-situ auto-aligning precision meso-punching system to investigate the burr formation mechanism and ultimately minimize burr. Firstly, we introduced the punch-die contact sensing method to align the punch and the die at initial state prior to the punching process. Secondly, by using the low-price semi-con­ductor laser, burr formed on the edges is measured intermittently during the punching process. We could, finally, make burr on the sheet metal uniformized and minimized by controlling of the precision X - Y table, $1\;{\mu}m$ resolution, and measuring burr height by semiconductor laser. Experimental results show the validity of our system for pursuing the burr-free punched elements.

Precision measuring of burrs on sheet metal using the laser (레이저를 이용한 박판 버의 정밀측정)

  • 신홍규;홍남표;김헌영;김병희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1824-1827
    • /
    • 2003
  • The sheet metal shearing process is normally used in the precision elements such as semi-conductor components. In precision elements, burrs usually reduce the quality of machined parts and cause interference, jamming and misalignment during assembly procedures and because of their sharpness, they can be safety hazard to personnel. Furthermore, not only burrs are hard to predict and avoid, but also deburring, the process of removing burrs, is time-consuming and costly. In order to get the burr-free parts, therefore, we developed the precise burr measuring system using the laser. The laser burr measuring system consists of the laser probe, the photo detector, the achromatic doublet lens, and the rotary & the X-Y table. In previous reports, we used simple vertical measuring method. But, as we used relatively bigger laser spot diameter and had the limited reflection angle, it was difficult to obtain the precise measuring results. So called, the spot size effect makes the profile of burr measured distorted and the burr height measured smaller. By introducing the novel laser measuring method which employing the achromatic lens system and the tilting mechanism, we could make the spot size smaller and get the appropriate beam direction angle. Through the experiments, the accuracy of the developed system is proved. The burr height measured during the punching process can be used for automatic deburring and in-situ aligning.

  • PDF