• Title/Summary/Keyword: wrist temperature

Search Result 27, Processing Time 0.024 seconds

Study on the interrelationship between the PWV and the temperature difference (맥파전달속도(PWV)와 말초체열분포(DITI)와의 관계 연구)

  • Lee, Yoon-Jae;Cho, Jung-Hoon;Lee, Chang-Hoon;Lee, Jin-Moo;Jang, Jun-Bock;Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.6 no.1
    • /
    • pp.23-31
    • /
    • 2008
  • Objective: The purpose of this study is to identify relationship between the PWV and the temperature difference. Methods: When it comes to senile patients who suffer from cold limbs, there is need to see whether or not the patient's low temperature of the limbs is do to arteriosclerosis. The Pulse Wave Velocity(PWV) is a non-invasive method measuring the artery's rigidness. And the Digital Infrared Thermal Imaging(D.I.T.I) is a non-invasive method to see the body's thermal change. Research on the interrelationship of the artery's rigidness and body's thermal distribution was done by using these two tests. The subjects of this research were patients between the age 40~65 who have done both the D.I.T.I and PWV in March 2005~ September 2005. They had to have no history of diabetes, coronary illnesses or cerebrovascular diseases which are diseases that can effect the outcome of the PVW, nor history of spondylopathy or dermatosis which can effect the outcome of the D.I.T.I. Results: The results were as follows. 1. There was a significant interrelationship between the right wrist-ankle PWV and the temperature difference of the right wrist-palm. 2. There was a significant interrelationship between the left wrist-ankle PWV and the temperature difference of the left wrist-palm. 3. There was no significant interrelationship between the right wrist-ankle PWV and the temperature difference of the right thigh-dorsum of foot. 4. There was no significant interrelationship between the left wrist-ankle PWV and the temperature difference of the left thigh-dorsum of foot. 5. The right ABI showed no significant interrelationship between the temperature difference of the right wrist-palm and the right thigh-dorsum of foot. 6. The left ABI showed no significant interrelationship between the temperature difference of the left wrist-palm and the left thigh-dorsum of foot. Conclusion: The study shows that there was a significant interrelationship between wrist-ankle PWV and the temperature difference of wrist-palm.

  • PDF

The change of muscle action potential and superficial temperature of spastic upper extremity in a patient with cerebral palsy by the water temperature (수온이 뇌성마비 환자의 상지 경련근의 표재 온도와 근 활동전위에 미치는 영향)

  • Seo Sam-Ki;Lee Jeong-Woo;Han Dong-Wook
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.4
    • /
    • pp.455-465
    • /
    • 2003
  • The purpose of this study was to describe the alteration of muscle action potential of spastic upper extremity in a patient with cerebral palsy by the water temperature. We used seven patients with cerebral palsy. Participants classified according to each group in $29^{\circ}C,\;35^{\circ}C$ by the water temperature. All subjects participated 2 session, which at least 1 week between session. The test was measured continuously pre test, post-test by thermometer and surface EMG. The following results were obtained; 1. In changes of surface temperature, wrist flexor and extensor were significantly decreased in $29^{\circ}C$ (p<0.001) group but were significantly increased $35^{\circ}C$ group(p<0.01). 2. In changes of surface temperature, wrist flexor and extensor were significantly differenced between $29^{\circ}C$ and $35^{\circ}C$ group(p<0.001). 3. In changes of muscle action potential, wrist extension antagonist were significantly increased in $29^{\circ}C$ group(p<0.05). 4. In changes of muscle action potential, wrist flexion agonist were more significantly increased in $29^{\circ}C$ group(p<0.01). 5. In changes of muscle action potential, wrist extension antagonist were significantly differenced between $29^{\circ}C$ and $35^{\circ}C$ group(p<0.05). These results lead us to the conclusion that changes of muscle action potential of spastic upper extremity in a patient with cerebral palsy were influenced by the water temperature. Therefore, a further direction of this study will be to provide more evidence that a moderate water temperature have an effect on muscle tone in a patient with cerebral palsy.

  • PDF

Signal Change and Compensation of Pulse Pressure Sensor Array Due to Wrist Surface Temperature (손목 피부 온도에 의한 맥센서 어레이(array)의 신호 변동 및 보정)

  • Jun, Min-Ho;Jeon, Young Ju;Kim, Young-Min
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.141-147
    • /
    • 2017
  • A pressure sensor in pulse measurement system is a core component for precisely measuring the pulse waveform of radial artery. A pulse sensor signal that measures the pulse wave in contact with the skin is affected by the temperature difference between the ambient temperature and skin surface. In this study, we found experimentally that the signal changes of the pressure sensors and a temperature sensor were caused by the temperature of the wrist surface while the pressure sensor was contacted on the skin surface for measuring pulse wave. To observe the signal change of the pulse sensor caused by temperature increase on sensor surface, Peltier device that can be kept at a set temperature was used. As the temperature of Peltier device was kept at $35^{\circ}C$ (the maximum wrist temperature), the device was put on the pulse sensor surface. The temperature and pressure signals were obtained simultaneously from a temperature sensor and six pressure sensors embedded in the pulse sensor. As a result of signal analysis, the sensor pressure was decreased during temperature increase of pulse sensor surface. In addition, the signal difference ratio of pressure and temperature sensors with respect to thickness of cover layer in pulse sensor was increased exponentially. Therefore, the signal of pressure sensor was modified by the compensation equation derived by the temperature sensor signal. We suggested that the thickness of cover layer in pulse sensor should be designed considering the skin surface temperature.

A Basic Study on Temperature Characteristic Analysis of Kumdo Motion by Infrared Rays Camera (열화상 카메라를 이용한 검도 동작의 온도 특성 분석 기초 연구)

  • Lee, Gyuseon;Nam, Joong Woong;Seok, Kang Hoon;Kim, Jeongbae
    • Journal of Institute of Convergence Technology
    • /
    • v.2 no.1
    • /
    • pp.18-23
    • /
    • 2012
  • The purpose of this study is to visually confirm on variation of temperature changes according to the basic of Kumdo by using infrared rays camera and to obtain the difference of temperature distribution according to the warm up procedure. We selected randomly two Kumdo players, and recorded twice continuously their actions of three basic(Head Hitting, Wrist Hitting, Waist Hitting) motions of Kumdo. In other to obtain the effect of warm up procedure, we recorded again their actions including warm-up motions. Four measuring points on the body were selected in each motion considering the error on continuous recoding. Temperature distributions of the before and after warming up procedure were analyzed at two measuring point. Skin temperature distributions of the players's body in two cases are shown a similar tendency. It can be predicted that the parts of large physical movement result in the large changes of temperature according to the warm up motion.

  • PDF

Development and Application of the Sleeve-type Restraints for Intensive Care Unit Patients (중환자실 환자를 위한 소매형 억제대의 개발 및 적용)

  • Ko, Hyun-Young;Kang, Jiyeon
    • Korean Journal of Adult Nursing
    • /
    • v.25 no.6
    • /
    • pp.665-678
    • /
    • 2013
  • Purpose: The purpose of this study was to develop sleeve-type restraints and to compare the sleeve-type and conventional wrist restraints. Methods: Forty four pairs of intensive care unit (ICU) patients and their families participated in the experiment. The nurses applied sleeve-type restraints to the patients in the experimental group, and wrist restraints to the control group. The trained research assistant measured ROMs, skin temperature, edema, and skin lesions of both upper extremities (UEs) before, 24, 48, and 72 hours after the restraints applied. The emotional response of family was measured 72 hours after the restraints applied. Thirty one ICU nurses evaluated the efficiency of both types of restraints. Results: Compared to the control group, changes of ROMs, edema, and skin abrasions on both U/Es of the experimental group indicated a significant difference in physical side effects. The emotional response scores of the experimental group were significantly lower than those of the control group. The mean efficiency scores for the sleeve-type restraints were significantly higher than those for the wrist restraints. Conclusion: The results indicate that the sleeve-type restraints are better than wrist restraints with respect to physical side effects, emotional responses of family members, and application efficiency.

A Study on Wrist Band Type Vital Sign Acquisition Device (손목형 생체신호수집 장치에 대한 연구)

  • Kim, Hee-Hoon;Kim, Kyung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.857-861
    • /
    • 2016
  • In this study, we proposed a new method that can be measure ECG (Electrocardiography) and PPG (Photoplethysmography) in realtime on the site of the wrist for check the state of health in daily life. For convenience measurement of ECG the lead I method was used on the wrist, and omit the reference junction ECG I was measured in the right hand and the left hand of the potential difference. Then the measured electrocardiogram was amplified by the differential amplifier and the signals were passed HPF, LPF, and BPF filters. For removing the PPG's noise from the Motion artifact and temperature, we apply the reflective photoelectric volume pulse wave measurement method using green LED as a light source. The circuits was designed to be able to check the waveform using higher active amplification method at weak signals. For the validation of our device, the measured signals were compared with E2-KIT on same time. The results shows that the error does not exceed the maximum one, most of the data is confirmed to be issued Peak inspection of the same number.

Effect of Acupuncture at the LU5(Reinforcement), LU10(Reduction) on the Pulsation Scale of Chon, Gwan and Chuk region using High Resolution Infrared Camera (척택.어제 침자가 고해상도 적외선 카메라로 관찰한 촌구맥 부위의 온도 Pulsation 변화에 미치는 영향 연구)

  • Na, Chang-Su;Jeon, Hyo-Sang;Kim, Jee-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.127-133
    • /
    • 2011
  • Arteria radialis is a branch of the brachial artery extending down the forearm around the wrist where it closes to skin surface. In the oriental medicine, the skin above arteria radialis has an important role because oriental medicine practitioners put their finger tips on the area, and diagnose patient's health conditions by feeling the pulsation of the arterial contraction. The finger tip diagnostic method relies on subjective decision of the practitioner; and there is a need to develop an objective diagnostic modality. The pulsation of the arterial contraction appears not only a movement on the site but also as temperature fluctuation due to pulsatile feeding of warmer blood. The goal of this study is to demonstrate a feasibility of using an infrared camera quantitatively to detect the temperature fluctuation on the skin. Clinical important three different areas, called chon, gwan, chuk, near a wrist where the arteria radialis reaches close to skin surface are marked with small pieces of surgical tape. A high-speed and high-resolution infrared camera with a 3 cm of field of view measures these areas for 10 second at 200 frames per second with a 320*240 pixel size. The pulsatile temperature fluctuation is calculated after passing a band pass filter to remove any stationary temperature over 10 second. The temperature fluctuation of a healthy male volunteer is measured at a room temperature as a control, and is compared with another measurement performed after 20 minutes staying in a room at a 40 degree Celsius. This comparison is repeated for three times, and indicates that the fluctuation increases after staying 20 minutes in the warm room. This increase becomes smaller when the person stays in the warm room with an acupuncture treatment that decreases body temperature. So that an objective diagnostics on the site may become feasible.

Development and Characterization of Wearable Film-heaters Used in Thermotherapy for Senior Citizens (노인의 온열치료를 위한 웨어러블 면상발열체의 개발 및 특성 파악)

  • Yang, Kyungwhan;Cho, Kyoungah;Choi, June-Seek;Im, Kiju;Kim, Sangsig
    • Journal of IKEEE
    • /
    • v.20 no.4
    • /
    • pp.412-415
    • /
    • 2016
  • In this study, we fabricated the wearable film-heaters used in thermotherapy for senior citizens and investigated the heat generation characteristics. The wearable film-heaters embedded into eco-flex were constructed with indium tin oxide (ITO) nanoparticles coated on glass fibers. Under a stretching strain of 30%, the wearable film-heaters stably operated with temperature variation of 10%. In addition, the wearable film-heater worn on the wrist increased the temperature of the wrist from $35^{\circ}C$ to $43^{\circ}C$ within 2 min.

Assessment of clothing ventilation by a trace gas method (Trace gas법에 의한 의복의 환기 양상의 평가)

  • 추미선
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.8
    • /
    • pp.1387-1395
    • /
    • 1997
  • Effects of the ambient air temperature and the opening position on the pattern of the clothing ventilation of a thermal manikin wearing an impermeable blouse were investigated by the trace gas method. Under an isothermal condition, the ventilation was governed by diffusion, and the ventilation rate through the wrist-openings was greatly affected by the distance from the openings. Under non-isothermal conditions, however, the ventilation was accelerated by the convection driven by the temperature gradient between the clothing microclimate and the surrounding air; the greater the temperature gradient, the greater the ventilation. Even though it was certainly affected by the ambient air temperature, the ventilation rate was more significantly influenced by the position of openings. The ventilation patterns at the arm and the body were distinctive.

  • PDF

Meteorological Factors Associated with the Number of Emergency Room Patients with Wrist-Cutting Behavior (손목자해로 응급실에 내원한 환자수와 기후인자와의 관련성)

  • Han, Jae Hyun;Suh, Seung Wan;Cho, Gyu Chong;Kim, Jung Mi;Seo, Hong Taek;Jung, Yu Jin;Seong, Su Jeong;Hwang, Jae Yeon;Lee, Won Joon
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.28 no.2
    • /
    • pp.161-167
    • /
    • 2020
  • Objectives : Although the seasonality of suicide is a well-known phenomenon, little is reported about the seasonality of non-suicidal self-injury. The purpose of this study was to identify the seasonality of wristcutting behavior and to examine its relationship with meteorological factors. Methods : To identify the presence of seasonality, we investigated whether there was a difference in the average number of visits per month to an emergency room (ER) of an urban hospital for 226 patients with wrist-cutting behavior enrolled between December 2014 and May 2019. To ascertain significant meteorological factors, we used the multiple Poisson regression using generalized additive model with time, monthly temperature, monthly sunshine hour, and atmospheric pressure in the prior month as explanatory variables. Results : In males, the average number of monthly visits to the ER for wrist cutting behavior differed by month and was the highest in September (male : p=0.048, female : p=0.21, total : p=0.28). As a result of multiple regression analysis, the average number of patients admitted to the ER for wrist cutting behavior was related to the interaction between atmospheric pressure in the prior month and temperature in males (p=0.010), and showed a positive correlation with sunlight in females [p=0.044, β=4.70×10-3, 95% CI=(1.19×10-4, 9.27×10-3)]. Conclusions : Wrist cutting behavior shows seasonality in male, which is associated with changes in meteorological variables.