• 제목/요약/키워드: wrist rehabilitation robot

검색결과 11건 처리시간 0.027초

3축 힘 센서가 적용된 손목 굽힘 재활로봇 개발 (Development of a Wrist Bending Rehabilitation Robot with a Three-axis Force Sensor)

  • 김갑순
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.27-34
    • /
    • 2016
  • This paper describes the development of a rehabilitation robot that can provide wrist bending exercise to a severe stroke patient staying in a bed ward or at home. The developed rehabilitation robot has a three-axis force sensor which detects three directional force Fx, Fy, and Fz. The sensor measures a bending force (Fz) exerted on the wrist and the signal force (Fx and Fy) which can be used for the safety purpose. The robot was designed for severe stroke patients in bed, and the robot program was developed to perform a wrist bending rehabilitation exercise. In our tests including a nine-day experimental exercise, the developed force sensor-based robot operated effectively and safely.

손목굽힘운동 재활로봇을 위한 3축 힘센서 설계 (Design of a Three-Axis Force Sensor for Wrist Bending-Exercise Rehabilitation Robot)

  • 김갑순
    • 센서학회지
    • /
    • 제22권2호
    • /
    • pp.118-123
    • /
    • 2013
  • Most serious stroke patients have the paralysis of their wrists, and can't use of their hands freely. But their wrists can be recovered by rehabilitation exercise. Recently, professional rehabilitation therapeutists exercise the wrists of stroke patients in hospital. But the wrists of stroke patients have not rehabilitated, because the therapeutists are much less than stroke patients in number. Therefore, the wrist bending-exercise rehabilitation robot that can measure the bending force of the patients' wrists is developed. In this paper, the three-axis force sensor was designed for the wrist bending-exercise rehabilitation robot. As a test results, the interference error of the three-axis force sensor was less than 0.85%. It is thought that the sensor can be used to measure the wrist bending force of the patient.

손목에 가해지는 힘측정을 위한 4축 힘/모멘트센서 설계 (Design of a Four-axis Force/Moment Sensor for Measuring the Applied Force to Wrist)

  • 홍태경;김갑순
    • 제어로봇시스템학회논문지
    • /
    • 제19권11호
    • /
    • pp.1011-1016
    • /
    • 2013
  • Patients have the paralysis of their wrists, and can't use of their wrists freely. But their wrists can be recovered by wrist-bending rehabilitation exercise. Professional rehabilitation therapeutists exercise the wrists of patients in hospital. But the wrists of patients have not exercised enough for the rehabilitation, because the therapeutists are much less than patients in number. Therefore, the wrist rehabilitation robot should be developed, and it have to measure the applied force to the patients' wrists for their safety. In this paper, the four-axis force/moment sensor was designed for the wrist rehabilitation robot. As a test results, the interference error of the four-axis force/moment sensor was less than 0.91%. It is thought that the sensor can be used to measure the applied force to the patients' wrists.

손목회전운동 재활로봇을 위한 6축 힘/모멘트센서 설계 (Design of a Six-axis Force/moment Sensor for Wrist Twist-exercise Rehabilitation Robot)

  • 김현민;김갑순
    • 한국정밀공학회지
    • /
    • 제30권5호
    • /
    • pp.529-536
    • /
    • 2013
  • Most serious stroke patients have the paralysis on their wrists, and can't use their hands freely. But their wrists can be recovered by rehabilitation exercises. Recently, professional rehabilitation therapeutists help stroke patients exercise their wrists in hospital. But it is difficult for them to rehabilitate their wrists, because the therapeutists are much less than stroke patients in number. Therefore, the wrist twist-exercise rehabilitation robot that can measure the twist force of the patients' wrists is needed and developed. In this paper, the six-axis force/moment sensor was designed appropriately for the robot. As a test result, the interference error of the six-axis force/moment sensor was less than 0.85%. It is thought that the sensor can be used to measure the wrist twist force of the patient.

A Study on the Robot Structure of Hand for the Rehabilitation Training of Stroke Patients

  • Kim, Jong-Bok;Kim, Jong-Chul;Hwang, Dae-Joon
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권3호
    • /
    • pp.116-124
    • /
    • 2019
  • The rehabilitation training robots for treating the upper limbs of stroke patients were mainly focused on the upper proximal treatment of it, but recently studies of the distal parts of the upper limbs for rehabilitation of the hand is making some progress even though it is still a small number so far. In this paper, we present the hand robot for the rehabilitation training of stroke patients that is the fingertip contact-typed mechanism, and it has also equipped with the wrist rehabilitation unit to be worked like human hand that enables any movements through mutual cooperation by fingers while picking up or grasping objects. The robot that is presented for this purpose supports the movement of fingers with 5-DoF and the wrist with 3-DoF that moves independently, and operates with a structure that allows the joints of the wrist and fingers to be collaborated organically together to each other. Also, hereby the simulation and evaluation test on its robot mechanism are performed to ensure that fingers with 5-DoF and the wrist with 3-DoF of the serial kinematical mechanism are designed to comply with or exceed ROM for ADL.

2 자유도 자동손목관절을 가진 근전 전동의수 개발 (Development of the Myoelectric Hand with a 2 DOF Auto Wrist Module)

  • 박세훈;홍범기;김종권;홍응표;문무성
    • 제어로봇시스템학회논문지
    • /
    • 제17권8호
    • /
    • pp.824-832
    • /
    • 2011
  • An essential consideration to differentiate prosthetic hand from robot hand is its convenience and usefulness rather than high resolution or multi-function of the robot hand. Therefore, this study proposes a myoelectric hand with a 2 DOF auto wrist module which has 6 essential functions of the human hand such as open, grasp, pronation, supination, extension, flexion, which improves the convenience of the daily life. It consists of the 3 main parts, the myoelectric sensor for input signal without additional attachment to operate the prosthetic hand, hand mechanism with high-torqued auto-transmission mechanism and self-locking module which guarantee the safety under the abrupt emergency and minimum power consumption, and dual threshold based controller to make easy for adopting the multi-DOF myoelectric hand. We prove the validity of the proposed system with experimental results.

상지마비 재활훈련로봇용 데이터글로브의 개발 (Development of a Data Glove for Rehabilitation Robot for Upper Extremity Paralysis)

  • 박찬영;문인혁
    • 재활복지공학회논문지
    • /
    • 제2권1호
    • /
    • pp.45-49
    • /
    • 2009
  • 본 논문에서는 상지마비 환자의 재활훈련용 로봇의 인터페이스에 사용할 수 있는 데이터글로브를 제안한다. 데이터글로브는 7개의 유연한 각도 센서를 적용하여 손가락과 손목의 굽힘 각도를 측정할 수 있다. 개발된 데이터글로브의 성능은 3D 그래픽을 이용한 시각화로서 확인하였다. 실험결과로부터 개발한 데이터글로브는 손의 움직임을 측정하고, 인터페이스로 사용할 수 있음을 보인다.

  • PDF