• Title/Summary/Keyword: would healing

Search Result 170, Processing Time 0.026 seconds

Truss Optimization based on Stochastic Simulated healing (SSA기법에 의한 트러스 최적화)

  • 이차돈;이원돈
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1992.04a
    • /
    • pp.73-78
    • /
    • 1992
  • A stochastic simulated anneal ins (SSA) is a recent approach to the solution of problems characterized by large number of interacting degrees of freedom. SSA simulates the degrees of freedom in a problem in a such a way that they are a collection of atoms slowly being coolded into a ground state which would correspond to the stationary point of the problem. In this paper, for a randomly disturbed current design, SSA optimization technique is used, which establishes a probabilistic criterion for acceptance or rejection of current design and iteratively improves it to arrive at a stationary Point at which critical temperature is reached. Simple truss optimization problem which consider as their constraints only the tensile and compressive yielding strength of the members are tested using SSA. Satisfactory results are obtained and some discussions are given for the behavior of SSA on the tested truss structures.

  • PDF

Local Irritation of DA-125 (DA-125의 국소자극성)

  • 안병옥;백남기;이순복;김원배;양중익;김부영;김대병;이종권
    • Biomolecules & Therapeutics
    • /
    • v.1 no.1
    • /
    • pp.20-25
    • /
    • 1993
  • DA-125, a new anthracycline derivative, shows significant anticancer activities. We conducted a study to examine the local irritating effect of DA-125 using mice and rabbits. In the skin test in mice, intradermal injection of 0.4 mg of DA-125, compared to a dosage of 0.2 mg of adriamycin, had weak irritating potentials to induce skin ulceration and erythematous induration. A dosage of 0.6 mg of DA-125 produced similar degree of lesions in perivascular irritation model to that of 0.2 mg of adriamycin, but the healing time was shorter in the case of mice treated with DA-125. In ocular irritation study in rabbit, the highest M.O.I.(mean ocular irritation index) of 0.5% DA-125 solution was 0.67, therefore DA-125 could be considered as a practically non-irritating anticancer agent. These results suggest that substitution of DA-125 for Adriamycin would reduces the possibility of outbreaks of local irritation and the severity of the lesions.

  • PDF

Nurses' Self-Image Perceived by Clinical Nurses: An Application of Q-Methodology (임상간호사가 지각한 간호사 자아상: Q 방법론적 접근)

  • Ha, Eun-Ho;Hyun, Kyoung Soon
    • Korean Journal of Adult Nursing
    • /
    • v.26 no.1
    • /
    • pp.117-128
    • /
    • 2014
  • Purpose: The views, perceptions, and feelings of nurses themselves would be important to quality of nursing and professionalism, and turnover intentions. The purpose of this study was to identify nurses 'self-image to develop a customized program. Methods: The Q-methodology which is to create a typology was used. The 40 selected Q-statements from each of 35 participants were classified into a shape of normal distribution using a nine point scale. The collected data were analyzed using a PC-QUANL program. Results: Three types of nurses 'self-image were identified: 'proactive self-image', 'critical self-image', and 'adaptive self-image'. Two consensus items in three types were extracted: 'need to develop healing therapies to overcome the constant tension and exhaustion from work', and 'just think as a colleague than the senior-junior relationship. Conclusion: The results is the typology and this leads to further research.

Intramedullary fibula strut bone allograft in a periprosthetic humeral shaft fracture with implant loosening after total elbow arthroplasty

  • Jo, Young-Hoon;Lee, Seung Gun;Kook, Incheol;Lee, Bong Gun
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.3
    • /
    • pp.152-155
    • /
    • 2020
  • Periprosthetic fracture after total elbow replacement surgery is a difficult complication to manage, especially when it comes together with implant loosening. If stem revision and internal fixation of the periprosthetic fracture are performed simultaneously, this would be a very challenging procedure. Most of total elbow replacement implants are cemented type. Cement usage at periprosthetic fracture site may interfere healing of fractured site. Authors underwent internal fixation with use of locking plate and cerclage wire for periprosthetic fracture, allogenous fibular strut bone inserted into the humerus intramedullary canal allowing the fractured site to be more stable without cement usage. At 10-month follow-up, the complete union and good clinical outcome was achieved. We present a novel technique for treating periprosthetic fracture with implant loosening after total elbow replacement surgery, using intramedullary allogenous fibula strut bone graft.

An Experimental Study on the Non-Exposure Composite Waterproofing Method used Adhesion Liquid and Sheet Integrate Waterproofing Material (점착형 도막.시트 일체형 방수재를 이용한 비노출용 복합 방수공법에 관한 실험적 연구)

  • Kim, Jin-Sung;Seon, Yun-Suk;Park, Jin-Sang;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.125-128
    • /
    • 2007
  • The problem of water leakage due to damaging waterproof in concrete structure, causes the impediment in a long term and shortened the life span of durability. There are a lot of techniques for repair and reinforcement to improve using environment. However, the improper construction which is unconsidered various environmental conditions, could effect to increase the maintenance expenses. Therefore, this study will be compared and estimated the adhesion liquid and sheet integrate waterproofing material, as analyzing the existing problem. For those result, we would like to arrange the alterative plan for the long durability and user needs of concrete structure.

  • PDF

Importance of various skin sutures in cheiloplasty of cleft lip

  • Kim, Soung Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.6
    • /
    • pp.374-376
    • /
    • 2019
  • Last week, after our receiving online journal regarding Journal of the Korean Association of Oral and Maxillofacial Surgeons, we found a recently published original article by Alawode et al., entitled "A comparative study of immediate wound healing complications following cleft lip repair using either absorbable or non-absorbable skin sutures". Although this clinical article was well written and provided a great deal of information regarding the suture materials in the cleft lip repair, I would like to add a few additional comments based on the importance of skin suture during cheiloplasties in the primary cleft lip or secondary revision patients with representative figures.

The diathermy scratch pad: A cheap and efficient tool for chemical and explosion-related burns

  • Wong, Allen Wei-Jiat;Hong, Qi En;Hui, Cheryl Li Yu;Chong, Si Jack
    • Archives of Plastic Surgery
    • /
    • v.46 no.1
    • /
    • pp.88-91
    • /
    • 2019
  • The burn center in our hospital is a national and regional (Southeast Asia) center. Of all admissions, 10% are related to blast explosions, and 8% due to chemical burns. In the acute burn management protocol of Singapore General Hospital, early surgical debridement is advocated for all acute partial-thickness burns. The aim of early surgical debridement is to remove all debris and unhealthy tissue, preventing wound infection and thereby expediting wound healing. In chemical burns, there can be stubborn eschars that are resistant to traditional debridement. We would like to present a novel technique using the diathermy scratch pad as a cheap and efficient tool for the dual purpose of surgical debridement and dermabrasion.

A novel modification of Bardach's two-flap palatoplasty for the repair of a difficult cleft palate

  • Mir, Mohd Altaf;Manohar, Nishank;Chattopadhyay, Debarati;Mahakalkar, Sameer S
    • Archives of Plastic Surgery
    • /
    • v.48 no.1
    • /
    • pp.75-79
    • /
    • 2021
  • Bardach described a closure of the cleft utilizing the arch of the palate, which provides the length needed for closure and is most effective only in narrow clefts. Herein, we describe a case where we utilized Bardach's two-flap technique with a vital and easy modification, done to allow closure of a wide cleft palate and to prevent oronasal fistula formation at the junction of the hard and soft palate, which are otherwise difficult to manage with conventional flaps. The closed palate showed healthy healing, palatal lengthening, and no oronasal regurgitation. We advise using this modification to achieve the goals of palatal repair in difficult cases where tension-free closure would otherwise be achieved with more complex flap surgical techniques, such as free microvascular tissue transfer.

3D Printed Titanium Implant for the Skull Reconstruction: A Preliminary Case Study

  • Choi, Jong-Woo;Ahn, Jae-Sung
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.2
    • /
    • pp.99-102
    • /
    • 2014
  • The skull defect can be made after the trauma, oncologic problems or neurosurgery. The skull reconstruction has been the challenging issue in craniofacial fields for a long time. So far the skull reconstruction with autogenous bone would be the standard. Although the autogenous bone would be the ideal one for skull reconstruction, donor site morbidity would be the inevitable problem in many cases. Meanwhile various types of allogenic and alloplastic materials have been also used. However, skull reconstruction with many alloplastic material have produced no less complications including infection, exposure, and delayed wound healing. Because the 3D printing technique evolved so fast that 3D printed titanium implant were possible recently. The aim of this trial is to try to restore the original skull anatomy as possible using the 3D printed titanium implant, based on the mirrored three dimensional CT images based on the computer simulation. Preoperative computed tomography (CT) data were processed for the patient and a rapid prototyping (RP) model was produced. At the same time, the uninjured side was mirrored and superimposed onto the traumatized side, to create a mirror-image of the RP model. And we fabricated Titanium implant to reconstruct three-dimensional orbital structure in advance, using the 3D printer. This prefabricated Titanium-implant was then inserted onto the defected skull and fixed. Three dimensional printing technique of titanium material based on the computer simulation turned out to be very successful in this patient. Individualized approach for each patient could be an ideal way to manage the traumatic patients in near future.

Use of regenerative tissue matrix as an oral layer for the closure of recalcitrant anterior palatal fistulae: a pilot study

  • Richardson, Sunil;Hoyt, James S.;Khosla, Rohit K.;Khandeparker, Rakshit Vijay Sinai;Sukhadia, Vihang Y.;Agni, Nisheet
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.2
    • /
    • pp.77-83
    • /
    • 2016
  • Objectives: To evaluate the effectiveness of regenerative tissue matrix (Alloderm) as an oral layer for difficult anterior palatal fistula closure. Materials and Methods: The authors have tested the feasibility of a novel surgical technique of adding a regenerative tissue matrix (Alloderm) as an oral layer for closure of recalcitrant large anterior palatal fistulae and report the outcome of the first 12 patients in this pilot study. Patients with recurrent large fistula who otherwise would require either a local pedicled flap, free flap, or an obturator were treated with this technique and followed up for at least 6 months to monitor the progress of healing. Results: Of the 12 patients, 8 patients (66.7%) had complete closure of the fistula, and 2 patients (16.7%) showed reduction in size of the fistula to the extent that symptoms were eliminated, for an overall success rate of 83.3% (10/12 patients). Premature graft loss and recurrence of the fistula were noted in 2 patients (16.7%). Conclusion: Alloderm provided an adequate barrier allowing healing to occur unimpeded and allowed closure of the palatal fistula. In our experience, this new technique using regenerative tissue matrix as an adjunct to the oral layer in large anterior palatal fistula has an advantage compared to other more invasive complex procedures and has been shown to provide satisfactory results.