• 제목/요약/키워드: work under water

검색결과 405건 처리시간 0.029초

주위 온도에 따른 Inconel690의 마멸 거동에 관한 연구 (A Study on Fretting-Wear Behavior of Inconel 690 due to Surrounding Temperature)

  • 임민규;박동신;김대정;이영제
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제34회 추계학술대회 개최
    • /
    • pp.296-303
    • /
    • 2001
  • In nuclear power steam generators, high flow rates can induce vibration of the tubes resulting in fretting wear damage due to contacts between the tubes and their supports. In this paper the fretting wear tests and the sliding wear tests were performed using the steam generator tube materials of Inconel 690 against STS 304. Sliding tests with the pin-on-disk type tribometer were done under various applied loads and sliding speeds at air and water environment. Fretting tests were done under various vibrating amplitudes, applied normal loads and various temperatures. From the results of sliding and fretting wear tests, the wear of Inconel 690 can be predictable using the work rate model. Depending on normal loads and vibrating amplitudes, distinctively different wear mechanisms and often drastically different wear rates can occur. At room temperature, the wear coefficient K of Inconel 690 is 7.57${\times}$10$\^$13/Pa$\^$1/ in air and it is 1.93${\times}$10$\^$13/Pa$\^$1/ in water. At room temperature, it is found that the wear volume in air is more than in water. In water, the wear coefficient K at 50$^{\circ}C$ and 80$^{\circ}C$ is 4.35${\times}$10$\^$-13/Pa$^1$ and 5.81${\times}$10$\^$-13/Pa$^1$ respectively, Therefore, it is found that the wear volume extremely increases by increasing on temperature in water. This study shows that the dissolved oxygen with temperature increment increases and the wear due to fluidity is severe.

  • PDF

Effect of nanobubbles (oxygen, ozone) on the Pacific white shrimp (Penaeus vannamei), Vibrio parahaemolyticus and water quality under lab conditions

  • Nguyen, Huu Nghia;Nguyen, Thi Nguyen;Phan, Trong Binh;Le, Thi May;Tong, Tran Huy;Pham, Thai Giang;St-Hilaire, Sophie;Phan, Thi Van
    • Fisheries and Aquatic Sciences
    • /
    • 제25권8호
    • /
    • pp.429-440
    • /
    • 2022
  • This study assessed the effects of oxygen and ozone nanobubbles on gill morphology, weight gain, and mortality of Pacific white shrimp (Penaeus vannamei), as well as the level of Vibrio parahaemolyticus and water quality of shrimp culture tanks under lab conditions. Two experiments were carried out with oxygen macrobubble, ozone macrobubble, oxygen nanobubble, ozone nanobubble, and control treatments (air-stone macrobubble). Experiments were done in triplicate in 100 L tanks with 15‰ saline water, and 20 shrimp per tank. Tanks in Experiment 1 were not inoculated with bacteria; tanks in Experiment 2 were inoculated with V. parahaemolyticus at a concentration of 106 CFU/mL. The results revealed that short treatments with ozone nanobubbles had minimal impact on shrimp gills, mortality, and growth rates, reduced V. parahaemolyticus concentration in water compared to the other groups, and improve water quality. These laboratory results indicate that ozone nanobubble treatment may be useful for controlling V. parahaemolyticus. More work is needed to find the best protocol to apply the technology on a commercial scale.

전(塼)의 백화현상 규명 및 제거방안 연구 - 수원화성 백화현상을 중심으로 - (Investigation and Removal Method of Efflorescence Phenomenon of Traditional Bricks - Focusing on the Efflorescence of Hwaseong Fortress in Suwon -)

  • 정광용;차현석
    • 건축역사연구
    • /
    • 제22권6호
    • /
    • pp.59-66
    • /
    • 2013
  • This study progressed an investigation on the cause of the efflorescence phenomenon of bricks in Suwon Hwaseong Fortress, which is designated as a UNESCO World Heritage by using diverse scientific analyses. The samples were taken in Hwaseong and analyzed using XRD and SEM-EDS for the material identification of efflorescence. We observed under a polarizing microscope and measured absorption factors for the basic investigation for traditional bricks. As a result of material identification, soluble salt($Na_2SO_4$, $KNO_3$) and insoluble salt($CaCO_3$) were detected. There was no big difference between original bricks and repaired bricks under the polarizing microscope. However, in terms of the water absorption rate, bricks which were used for repair nowadays showed low water absorption rate(1%). In conclusion, soluble salt and insoluble salt appeared due to an effect of an air pollution and joint mortar. Soluble salt was removed in the rainy season, but insoluble salt was not removed. As a result of the efficiency and safety tests for chemicals removing efflorescence, chemical E is likely to be the suitable chemicals for the efflorescence phenomenon of traditional bricks in Suwon Hwaseong Fortress. In the future, consideration whether the use of lime is available or not should be studied through comprehensive researches including repair work, construction work and the environment factor with lime. Also, physical, chemical identifications of repairing bricks will be required.

$Co^{60}$ $\gamma$-선으로 조사된 Polyethylene에서 수트리 현상의 구조적 측면에 관한 연구 (Morphological Aspects of Water Treeing in $Co^{60}$ $\gamma$-ray Irradiated Polyethylene)

  • 이방욱;김정태;구자윤;류부형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.435-438
    • /
    • 1991
  • This work is aimed to clarify the effect of only crosslinking of polyethylene on the water tree propagation and thus the crosslinking of LDPE was made by use of $Co^{60}$ $\gamma$-ray irradiation at room temperature. For this purpose, before water tree testing under same test conditions, injection molded samples were made of LDPE using CNRS laboratory model and also some of them were irradiated under different dose rate for crosslinking. Afterwards, the aged specimens were put into microscopic investigation as a mean to compare their different morphological aspects by use of SEM for the fractured surface. The SEM observation points out that the untreed region in the irradiated PE shows the densed structure whereas that in the LDPE is not closely packed. Also in the water treed region of LDPE, the density and the dimension of voids are higher than those in irradiated PE. Based on our results, it seems that the difference in the PE structure could sufficiently contribute to cause the different water tree propagation of these materials.

  • PDF

A Development Study on High Quality Drinking Water Production by the Biological Activated Carbon/immersed Membrane Filtration System

  • Inoue, Shiro;Iwai, Tosinori;Isse, Masaaki;Terui, Taturo
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2001년도 국제 Workshop:상수원의 현황과 분리막 상수처리(Water Resource and Menbrane Water Treatment)
    • /
    • pp.155-162
    • /
    • 2001
  • Advanced drinking water production systems, which not only good quality product water, but also provide easy management and mainenance of facilities, and operate on a smaller site area, have been expected to be developed for some time. We are going ahead with a program to deveop an advanced drinking water production system, using immersed membrane filtration combined with biological activated carbon, to meet the need described above. The demonstration plant tests been conducted with surface water from the Yodo-river since Dec. 1998 to measure treatment performance, reliability, and controllability of the system. The quality of product water has consistently remained at a very high level for about 2 years under controlled conditions. Results showed that the re-circulation granular biological activated carbon could suppress the increase of membrane pressure difference and promote a reduction of dissolved organic matter. (This work has been conducted along the ACT21 Programs.)

  • PDF

Fluid-structure interaction analysis of sloshing in an annular - sectored water pool subject to surge motion

  • Eswaran, M.;Goyal, P.;Reddy, G.R.;Singh, R.K.;Vaze, K.K.
    • Ocean Systems Engineering
    • /
    • 제3권3호
    • /
    • pp.181-201
    • /
    • 2013
  • The main objective of this work is to investigate the sloshing behavior in a baffled and unbaffled three dimensional annular-sectored water pool (i.e., tank) which is located at dome region of the primary containment. Initially two case studies were performed for validation. In these case studies, the theoretical and experimental results were compared with numerical results and good agreement was found. After the validation of present numerical procedure, an annular-sectored water pool has been taken for numerical investigation. One sector is taken for analysis from the eight sectored water pool. The free surface is captured by Volume of Fluid (VOF) technique and the fluid portion is solved by finite volume method while the structure portions are solved by finite element approach. Baffled and un-baffled cases were compared to show the reduction in wave height under excitation. The complex mechanical interaction between the fluid and pool wall deformation is simulated using a partitioned strong fluid-structure coupling.

수조구조물의 방수.방식 공사용 유기.무기 소재 및 섬유보강형 바탕처리재의 성능평가에 관한 연구 (A Study on Waterproofing and Anticorosive Performance Evaluation of Surface treatment material used wi th Glass Fiber, Inorganic and Organic Material for Water Tank)

  • 오상근;박봉규;주웅일;박성진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2001년도 학술논문발표회
    • /
    • pp.70-75
    • /
    • 2001
  • There is a problem to be solved for improvement of durability and safety for concrete When the waterproofing and anticorrosive work of main concrete are design, the material a of construction need to be correctly applied to appropriate circumstance conditions. Epoxy mostly been used for concrete water tank structure. Lately, lots of subjects on adaption res in mortar for waterproofing and anticorrosive are under discussion. Then, we attempt to approach by evaluating and comparing every capabilities with waterproofing materials in this experiment. Capability evaluation items include the bond age and curing conditions, the bond strength after accelerated weathering test and fret impact resistance, a mount of water, seepage quan Through the experiment analysis, we found that waterproofingtity, drinking water chemicals resistance. and anticorrosive resin mortar used with glass fiber cloth, inorgar material is dominantly superior to other waterproofing materials. According to this paper, we suggest the resin mortar as a new surface treatment material water tank structure.

  • PDF

경량기포혼합 준설토의 강도특성 (Strength Characteristics of Light-Weight Cement mind Marine Clay with Foam)

  • 박건태;김주철;윤길림;이종규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.483-490
    • /
    • 2002
  • A massive amount of marine clay produced as dredging of coast and sea bed is often dumped in open sea and filled in pond. The treatment of marine clay demand a large area and make fatal environmental problems for echo system. This research work intend to manufacture a light-weight landfill materials which are produced by mixing the dredged marine clay with various amount cement and foam. An extensive Uniaxial and Triaxial compression test are carried out to investigate the strength characteristics of the light-weight cement mixed marine clay with foam under various test conditions. The results indicated that the required unit weight has been achieved with negligible change after 28days curing time in water. It is also recognized that the compressive strength of light-weight landfill materials linearly decrease with increasing initial water content, and the rate of strength decrease with increasing initial water content in water curing was smaller than that of air curing Futhermore, the rate of strength decreased with increasing initial water content, however, the rate become smaller as cement content increased.

  • PDF

Mitigation of Flooding under Externally Imposed Oscillatory Gas Flow

  • Lee, Jae-Young;Chang, Jen-Shih
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(1)
    • /
    • pp.475-479
    • /
    • 1995
  • During the hypothetical loss of coolant accident in the nuclear power plant the emergency core cooling water could not penetrate to the reactor core when the steam flow rate from the reactor core exceeds CCFL (Countercurrent flow limitation). The CCFL generated by earlier investigators are developed under the steady gas flow. However the flow instability in the reactor loop could generate oscillatory steam flow, hence their applicability under oscillating flow should be investigated. In this work, an experimental investigation of countercurrent flow in the vertical flow channel has been conducted under oscillatory gas flow. Pulsation of gas under oscillatory flow disturbs the flow pattern significantly and prevents flooding (CCFL) when its minimum value is less than the threshold gas flow rate value.

  • PDF

원자로 외벽냉각시 원자로공동에서의 자연순환 이상유동에 대한 수치적 연구 (A Numerical Study on the Two-Phase Natural Circulation Flow in Reactor Cavity under External Vessel Cooling)

  • 김홍민;서준우;김광용;박래준;하광순;김상백
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.781-785
    • /
    • 2003
  • This work presents a numerical analysis of two-phase natural circulation flow in reactor cavity under external vessel cooling. Steady, incompressible, three-dimensional Reynolds-averaged Navier-Stokes equations for multiphase flows with zero equation turbulence model are solved to predict the shear key effect on the circulation rate of cooling water and the distribution of void fraction according to the different mass flow of inlet air. Results show that shear key has a positive effect on the circulation rate of cooling water and induce a local increase of void fraction below the shear key, but not remarkably.

  • PDF