• Title/Summary/Keyword: work condition

Search Result 3,205, Processing Time 0.031 seconds

Study on Seombody Drying (섬바디의 건조에 관한 연구)

  • Park, Kyung-Kyu;Chung, Chang-Joo
    • Journal of Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.55-55
    • /
    • 1976
  • An experimental work was conducted to develop an optimum operating system of various hay drying systems ; sun-drying with long hay, sun-drying after chopping, sun-drying after crushing, heated air drying after chopping using batch-type dryer and heated air drying after crushing using tunnel-type dryer. Seombody having 60 cm long and initial moisture content of approximately 79 % in wet basis was used for the experiment. The criteria selected for determining the optimum operating condition were the drying performance rate, the production cost and quality of dried matter of each drying systems. The result of this study are summarized as follows : 1. Drying characteristics of leaves of long stem hay, chopped seombody and crushed one were obtained by maintaining the oven temperature at 70 degrees centigrade. The required drying times for various samples to approximately 15% moisture content in wet basis were about 50 min .for leaves ; 160 min. for crushed hay ; 250 min. for chopped hay ; 340min. for ling hay and more than 360 min .for stems. The drying time of crushed hay was required about 50 % of that for the uncrushed long hay. Such a significant difference of drying of time between the leaf and long stem may indicate that an effective drying of seombody may not be achieved unless any kind of special process treatment for the whole hay is undertaken. 2. In each individual drying system, the following conclusions were drawn: a. After 8 days sun-drying on concrete floor under good days with average tempe?rature at $256{\circ}C$ and relative humidity at 55% at 2 P.M., the moisture content of long hay was still above 25 5'~ and the leaf loss during drying caused by wind and rough handling was more than 50 ~G. b. It was possible to dry the chopped seombody by sun-drying down to about 10 % moisture content within 5 days, however, a stock of heat and discolouration phenomena were observed during the drying, which may be due to the increased deposit-density by chopping, resulting in lowering the quality of the dried product. c. Sun-drying for the crushed material by hay-conditioner was required about 4 days to reduce the moisture content to about 10 %, keeping the quality of dried product at good grade. o. The optimum deposit-depth of the chopped seombody in the batch-type dryer used was about 28cm with about 42kg/hr of drying performance rate. However, it was necessary to overturn the materials between the upper and lower layers in order to obtain a good quality of dried product. d. The drying performance rate by the tunnel-type drier was highest among those of drying systems tested, giving the rate of approximately 400kg/day. 3. On reviewing the individual drying system for seombody, it was possible to draw conclusion that the best system was tunnel drying with the crushed seombody as far as the performance rate was concerned. However, the methods gives the highest operational cost. The system for the lowest operational cost with good quality of dried product was the sun-drying with the crushed material. Accordingly, it may be recommended that the system of sun-drying for the crushed seombody may be the most feasible system presently applicable to farm-level operation.

Study on Seombody Drying (섬바디의 건조에 관한 연구)

  • 박경규
    • Journal of Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.56-63
    • /
    • 1976
  • An experimental work was conducted to develop an optimum operating system of various hay drying systems ; sun-drying with long hay, sun-drying after chopping, sun-drying after crushing, heated air drying after chopping using batch-type dryer and heated air drying after crushing using tunnel-type dryer. Seombody having 60 cm long and initial moisture content of approximately 79 % in wet basis was used for the experiment. The criteria selected for determining the optimum operating condition were the drying performance rate, the production cost and quality of dried matter of each drying systems. The result of this study are summarized as follows : 1. Drying characteristics of leaves of long stem hay, chopped seombody and crushed one were obtained by maintaining the oven temperature at 70 degrees centigrade. The required drying times for various samples to approximately 15% moisture content in wet basis were about 50 min .for leaves ; 160 min. for crushed hay ; 250 min. for chopped hay ; 340min. for ling hay and more than 360 min .for stems. The drying time of crushed hay was required about 50 % of that for the uncrushed long hay. Such a significant difference of drying of time between the leaf and long stem may indicate that an effective drying of seombody may not be achieved unless any kind of special process treatment for the whole hay is undertaken. 2. In each individual drying system, the following conclusions were drawn: a. After 8 days sun-drying on concrete floor under good days with average tempe\ulcornerrature at $256{\circ}C$ and relative humidity at 55% at 2 P.M., the moisture content of long hay was still above 25 5'~ and the leaf loss during drying caused by wind and rough handling was more than 50 ~G. b. It was possible to dry the chopped seombody by sun-drying down to about 10 % moisture content within 5 days, however, a stock of heat and discolouration phenomena were observed during the drying, which may be due to the increased deposit-density by chopping, resulting in lowering the quality of the dried product. c. Sun-drying for the crushed material by hay-conditioner was required about 4 days to reduce the moisture content to about 10 %, keeping the quality of dried product at good grade. o. The optimum deposit-depth of the chopped seombody in the batch-type dryer used was about 28cm with about 42kg/hr of drying performance rate. However, it was necessary to overturn the materials between the upper and lower layers in order to obtain a good quality of dried product. d. The drying performance rate by the tunnel-type drier was highest among those of drying systems tested, giving the rate of approximately 400kg/day. 3. On reviewing the individual drying system for seombody, it was possible to draw conclusion that the best system was tunnel drying with the crushed seombody as far as the performance rate was concerned. However, the methods gives the highest operational cost. The system for the lowest operational cost with good quality of dried product was the sun-drying with the crushed material. Accordingly, it may be recommended that the system of sun-drying for the crushed seombody may be the most feasible system presently applicable to farm-level operation.

  • PDF

Structure and physical properties of the earth crustal material in the middle of Korean Peninsula : A study on the prescription of standard test by mortar-bar method (한반도 중부권 지각물질의 구조와 물성연구 : 콘크리트 공시체에 의한 표준시험 규정에 대하여)

  • 정진곤;유신애
    • The Journal of Engineering Geology
    • /
    • v.5 no.2
    • /
    • pp.193-200
    • /
    • 1995
  • It has been well known that the alkali-aggregate reaction between the aggregates and cement paste is one of the reasons of a concrete siructre expansion. Because of a serious demage on the concrete stnicture from the expansion, in many countries, the safety of the materials is checked in laboratory by mortar-bar test and the upper limit of expansion in length is 0.1%. The prescriptions are presented in the ASTM C227 and 490 of U.S. which has been international currency and in the KS Handbook F2503, F2546 and L5107 of Korea published by Korean Standards Association. Both of the prescriptions are almost same in their contents. Actually, in the process of preparing and measuring the mortar-bar according to the prescription mentioned above, it seems that there are no problems for its own purpose but a few points are found to be improved upon the methods to increase the accuracy for laboratory work as follows. 1. The prescription of blending ratio(aggregate, cement and water) should be noted by volume not by weight. 2. It is unreasonable to measure the initial length of mortar bars after 24$\pm$2 hours at once regardless the kind of aggregates. 3. It may bring about errors in calculating the expansion ratio under the condition of the denominator value fixed as 254mm. 4. The measuring methods of specific gravity are selected according to the purposes but the pure specific gravity displays the highest accuracy among them.

  • PDF

Analysis of Effects of Reshoring Works on Short and Long Term Deflections of Flat Plates (플랫 플레이트 구조의 장단기 처짐 제어에 대한 동바리 재설치 작업의 효과 분석)

  • Kim, Jae-Yo;Park, Soo-Beom
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.1
    • /
    • pp.40-48
    • /
    • 2017
  • RC flat plates may be governed by a serviceability as well as a strength condition, and a construction sequence and its impact on the distributions of gravity loads among slabs tied by shores are decisive factors influencing short and long term behaviors of flat plate. Over-loading and tensile cracking in early-aged slabs significantly increase the deflection of a flat plate system under construction, and a reshoring work may be helpful in reducing slab deflections by controlling the vertical distributions of loads in a multi-shored flat plate system. In this study, a effect of reshoring works on short and long term deflections of flat plate systems are analyzed. The slab construction loads with various reshoring schemes and slab design and construction conditions are defined by a simplified method, and the practical calculation of slab deflections with considering construction sequences and concrete cracking and long term effects is applied. From parametric studies, the reshoring works are verified to reduce slab deflections, and the optimized conditions for the reshoring works and slab design and constructions are discussed.

Crack and Time Effect on Chloride Diffusion Coefficient in Nuclear Power Plant Concrete with 1 Year Curing Period (1년 양생된 고강도 원전 콘크리트의 염화물 확산에 대한 균열 및 시간효과)

  • Chun, Ju-Hyun;Ryu, Hwa-Sung;Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.83-90
    • /
    • 2017
  • Concrete structure for nuclear power plant is mass concrete structure with large wall depth and easily permits cracking in early age due to hydration heat and drying shrinkage. It always needs cooling water so that usually located near to sea shore. The crack on concrete surface permits rapid chloride intrusion and also causes more rapid corrosion in the steel. In the study, the effect of age and crack width on chloride diffusion is evaluated for the concrete for nuclear power plant with 6000 psi strength. For the work, various crack widths with 0.0~1.4 mm are induced and accelerated diffusion test is performed for concrete with 56 days, 180days, and 365 days. With increasing crack width over 1.0mm, diffusion coefficient is enlarged to 2.7~3.1 times and significant reduction of diffusion is evaluated due to age effect. Furthermore, apparent diffusion coefficient and surface chloride content are evaluated for the concrete with various crack width exposed to atmospheric zone with salt spraying at the age of 180 days. The results are also analyzed with those from accelerated diffusion test.

The Ammonia Removal Capacity of a Few Kinds of Filter Media in a Water Reuse quaculture System (순환 여과식 양식 시설에 이용될 수종의 여과 재료의 효능에 관한 연구)

  • KIM In-Bae;KIM Pyong-Kih;CHEE Young-Ok
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.20 no.6
    • /
    • pp.561-567
    • /
    • 1987
  • The purpose of this study was to find out the removal capacity of harmful ammonia by different filter media in the submerged biological filters in a given space of chamber. Four materials, pile cloth, corrugated skylight roofing plate, embossed plastic plate, and gravel, were used as the experimental filter media. Each filter medium was placed in two aquariums, each aquarium measuring $90cm\times60cm\times60cm\;(depth)$. Under the normal operating condition, the average of mean ammonia removal rates during the first and second functioning periods by each filter material which occupied tile space in the filter chamber (aquarium) was as follows: 1. Pile cloth: $8.381\;g{\cdot}m^{-3}.\;day^{-1}$ 2. Corrugated skylight roofing plate: $7.834\;g{\cdot}m^{-3}.\;day^{-1}$ 3. Embossed plastic plate: $7.797\;g{\cdot}m^{-3}.\;day^{-1}$ 4. Gravel: $7.051\;g{\cdot}m^{-3}.\;day^{-1}$ Thus, there were no significant differences between the media, but at the time of practical application of these materials, some other factors such as investment cost, easiness for the removal of excess detritus accumulated in tile interstices of filter media, etc. should be fallen into consideration. When large units are required, in particular, removal of excess detritus from tile gravel bed is extremely difficult, and in case of pile cloth filters the installation work is much complicated and a problem in supporting the structure when drained also exists. In these respects, corrugated skylight roofing plate and embossed plastic plate seem to be more optimal, but again in practice the local situation for the availability and the price of the materials should be rechecked and the fitness of tile materials in the particular filter chambers under use or under consideration for construction must be taken into account.

  • PDF

Behaviors of Glucose Decomposition during Dilute-Acid Hydrolysis of Lignocellulosic Biomass (목질계 바이오매스의 묽은 산 가수분해 공정에서 포도당 분해물 거동)

  • Jeong, Tae-Su;Oh, Kyeong-Keun
    • KSBB Journal
    • /
    • v.24 no.3
    • /
    • pp.267-272
    • /
    • 2009
  • During a dilute acid hydrolysis, degradation products are formed or liberated by pre-treatment of lignocelluloses depend on both the biomass and the pretreatment conditions such as temperature, time, pressure, pH, redox conditions, and addition of catalysts. In lignocellulosic biomass, sugars can be degraded to furfural which is formed from pentoses and 5-hydroxymethulfurfural (HMF) from hexoses. 5-HMF can be further degraded, forming levulinic acid and formic acid. Acetate is liberated from hemicellulose during hydrolysis. Some decomposed compounds hinder the subsequent bioconversion of the solubilized sugars into desired products, reducing conversion yields and rates during fermentation. In the present work, samples of rapeseed strawwere hydrolyzed to study the optimal pretreatment condition by assessing yields of sugars and decomposed products obtained under different reaction conditions ($H_2SO_4$ 0.5-1.25% (w/w), reaction time 0-20 min and temperature range 150-220 C). A careful analytical investigation of acid hydrolyzate of rapeseed straw has not yet been undertaken, and a well-closed mass balance for the hydrolyzate in general is necessary to verify the productivity and economic predictions for this process.

A Scheduling Method Of Dismantling Work Considering Specific Condition Of Remodeling Project - Focused on Old Aged Apartment House with Wall-Slab Structure - (리모델링의 특성을 반영한 철거공사의 공정계획 수립방안 - 벽식구조 노후 공동주택을 대상으로 -)

  • Kang, Sa-Yil;Hwang, Young-Kyu;Kim, Kyung-Rai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.9 no.5
    • /
    • pp.104-115
    • /
    • 2008
  • Currently, reconstruction and remodeling are conducted to improve the performance of aged housing. Recently reconstruction has caused many problems such as wastes generation, wasting resources and real estate speculation, remodeling is drawing attention. Accordingly, remodeling business for aged housings gradually increasing, but the use of scheduling method not considering characteristics of remodeling deters construction in some construction types. Especially, in case of dismantling construction, the dismantling is delayed since the scheduling method not considering characteristics of remodeling is used. In case of remodeling, dismantling construction is ahead of other processes, if the dismantling construction is delayed, whole construction will be delayed and if speedy construction is conducted, the costs for remodeling will increase. Furthermore, existing remodeling for aged housing has been for rahmen(crossbeam and pillar) structure apartments, but since most apartments to be remodeled are wall-slab structure where dismantling takes a lot of weight, it is highly possible the dismantling construction is delayed. Thus, this paper is to establish scheduling method for the dismantling construction reflecting characteristic of remodeling to prevent delay of dismantling construction for remodeling of aged housing with wall-slab structure.

Estimation of Application on the Site of SRC Method for the Ground Reinforcement in Marine Clay (해성점토층에서 SRC 지반보강에 관한 현장적용성 평가)

  • Lee, Seungjun;Lee, Seogyoung;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.1
    • /
    • pp.23-32
    • /
    • 2013
  • Currently, the west coast has focused on large-scale investment and development, such as harbor construction work and land reclamation projects, with soft ground grouting issues being the major concern. In addition, grouting for soft ground reinforcement is definitely considered that construction purpose, soil condition, construction situation, and construction costs. The SRC method, which is a high pressure injection method, can easily produce well-distributed strength regardless of soil characteristics and is environmentally friendly. Therefore in this study, the SRC method was applied to marine clay on the west coast where located Jeongok-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, Korea as well as estimated of the ground reinforcement and the application on the site. The results of the application on the site by SRC method indicated age 28 day strength is $14,700{\sim}31,800kN/m^2$ which is satisfied the criterion of unconfined compressive strength that more than $5,333kN/m^2$. Therefore the result that the SRC method constructed marine clay on the west coast indicated the outstanding strength as well as excellent durability.

A Rapid Method for the Measurement of $^{222}Rn$ in Groundwater and Hot Spring Water using Ultra Low-Level Liquid Scintillation Counter and Pulse Shape Analysis (극저준위 액체섬광계수기와 파형분석법을 이용한 지하수 및 온천수중 $^{222}Rn$의 신속측정법)

  • Kim, Chang-Kyu;Kim, Cheol-Su
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.103-115
    • /
    • 1995
  • For the determination of $^{222}Rn$ in water by a very simple and time saving liquid scintillation counting method that does not require any chemical separation, an optimum analytical condition has been investigated. The optimum pulse shape analysis(PSA) level for the measurement of $^{222}Rn$ using LKB 1220 Quantulus liquid scintillation counter was 110 for Optiphase HiSafe3 cocktail and 90 for toluene-based cocktail. The counting efficiencies of $^{222}Rn$ in the window covering u spectra using Optiphase HiSafe3 cocktail were 282.2% for glass vial and 271.6% for Teflon vial, whereas the counting efficiencies in toluene-based cocktail were 262.3% and 247.5% for glass and Teflon vials, respectively. The minimum detectable activity(MDA) in the u window for a 60-min measurement with a Teflon vial using Optiphase HiSafe3 cocktail was $0.30Bq/{\iota}$. The analytical method studied from this work was also applied to the determination of $^{222}Rn$ in some groundwater and hot spring water samples.

  • PDF