• 제목/요약/키워드: wood-based panels

검색결과 53건 처리시간 0.02초

목질판상제품의 포름알데히드 방출등급과 항균성 평가 (Evaluation of Anti Fungal Efficacy on Different Formaldehyde Level of Wood-Based Composite Panels)

  • 손동원;박상범
    • 한국가구학회지
    • /
    • 제24권3호
    • /
    • pp.257-262
    • /
    • 2013
  • This study was carried out to investigate the susceptibility of wood-based composite panels exposed to mould and sap-stain fungi. Five wood deterioration fungi (three mould fungi, two sap stain fungi) were inoculated into two types of commercial wood-based composite panels (medium density fiberboard and particleboard), which have three class of formaldehyde emission. All wood-based composite panels were more or less susceptible to mould and sap stain fungi. The attacking mode of the fungi was highly dependent on formaldehyde emission. This study indicates that all wood-based composite panels, specially low formaldehyde emission class panels should be considered to prevent fungal deterioration when they are used for exterior and humid interior applications.

  • PDF

Lateral Resistance of CLT Wall Panels Composed of Square Timber Larch Core and Plywood Cross Bands

  • JANG, Sang Sik;LEE, Hyoung Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • 제47권5호
    • /
    • pp.547-556
    • /
    • 2019
  • Thinned, small larch logs have small diameters and no value-added final use, except as wood chips, pallets, or fuel wood, which are products with very low economic value; however, their mechanical strength is suitable for structural applications. In this study, small larch logs were sawed, dried, and cut into square timbers (with a $90mm{\times}90mm$ cross section) that were laterally glued to form core panels used to manufacture cross-laminated timber (CLT) wall panels. The surface and back of these core panels were covered with 12-mm-thick structural plywood panels, used as cross bands to obtain three-ply CLT wall panels. This attachment procedure was conducted in two different ways: gluing and pressing (CGCLT) or gluing and nailing (NGCLT). The size of the as-manufactured CLT panels was $1,220mm{\times}2,440mm$, the same as that of the plywood panels. The final wall panels were tested under lateral shear force in accordance with KS F 2154. As the lateral load resistance test required $2,440mm{\times}2,440mm$ specimens, two CLT wall panels had to be attached in parallel. In addition, the final CLT panels had tongued and grooved edges to allow parallel joints between adjacent pieces. For comparison, conventional light-frame timber shear walls and midply wall systems were also tested under the same conditions. Shear walls with edge nail spacing of 150 mm and 100 mm, the midply wall system, and the fabricated CGCLT and NGCLT wall panels exhibited maximum lateral resistances of 6.1 kN/m (100%), 9.7 kN/m (158%), 16.9 kN/m (274%), 29.6 kN/m (482%), and 35.8 kN/m (582%), respectively.

GC/FID와 GC/MS 분석법에 의한 목질제품에서의 VOC 방출특성 비교 (The Comparison of VOC Characteristics Emitted from Wood-based Panels Using GC/FID and GC/MS)

  • 황윤서;박현주;손윤석;김조천
    • 한국대기환경학회지
    • /
    • 제27권4호
    • /
    • pp.436-442
    • /
    • 2011
  • In this study, the Total Volatile Organic Compounds (TVOC) emitted from wood-based panels were compared by two analytical methods using the GC/FID and the GC/MS. Japanese Larch, Yellow Poplar, Particle Board (PB) and Medium Density Fiberboard (MDF) were selected as target materials. Major compounds emitted from the panels were Toluene, ${\alpha}$-pinene, ${\beta}$-pinene and limonene. In case of TVOC using GC/FID method, MDF E2 (1,497 ${\mu}g/m^3$) revealed the highest concentration among all wood-based panels, while Japanese Larch (1,772 ${\mu}g/m^3$) showed the highest value with respect to GC/MS method. Furthermore, it was found that the amount of VOC emitted from panels was different depending upon analytical methods. This significant difference was attributed to analytical sensitivities of GC/FID and GC/MS for various VOC. Besides, it was found that the composition ratios of main VOC compounds were not significantly different.

Formaldehyde Emission of Wood-Based Composite Panels with Different Surface Lamination Materials Using Desiccator Method

  • Park, Byung-Dae;Kang, Eun Chang;Lee, Sang-Min;Park, Jong Young
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권4호
    • /
    • pp.600-606
    • /
    • 2016
  • Wood-based composite panels such as plywood, particleboard (PB), or medium density fiberboard (MDF) are mostly used in the lamination on their surface for the manufacturing of furniture, or interior building products, the concern on the formaldehyde emission (FE) from the surface laminated wood panels is increasingly attracting attentions from the public. Thus, this study was conducted to understand influence of surface laminating materials to the FE from PB and MDF with or without edge sealing, using 24-hour desiccator method. Both PB samples that had been laminated on their surface with low-pressure laminate (LPL) or polypropylene (PP) film and MDF that had been treated with poly(vinyl chloride) (PVC) or coating were tested for the FE with or without edge sealing. As expected, the FE of PB with the sealed edges decreased to 37.4% and 80.7% with the LPL and PP lamination, respectively. The surface laminated MDF with the sealed edges also showed a decrease in the emission up to 57.8% and 54.3%, with the PVC lamination and coating, respectively. However, the coated MDF samples showed 5.3% increase in the emission when their edges were not sealed, indicating a FE form the solvent used for coating. These results showed that the type of surface lamination materials on wood-based composite panels has a great impact on their resultant FE, indicating that the influence of surface laminating materials should be taken into consideration for the formaldehyde mission measurement.

산소지수거에 의한 라왕소재(素材)와 목질판상재료(木質板狀材料)의 연소특성(撚燒特性)에 관한 예비연구 (Preliminary Studies on Combustion Properties of Lauan Solid Wood and Some Wood-Based Materials by Oxygen Index Method)

  • 이필우;김현중;엄영근
    • Journal of the Korean Wood Science and Technology
    • /
    • 제17권4호
    • /
    • pp.77-82
    • /
    • 1989
  • In this study the oxygen index method was used to compare the duration of flaming and the rate of weight loss at the level of 6 and 9mm panel thicknesses among solid wood, plywood, particleboard, and medium density fiberboard. The obtained results were as follows: 1. In 9mm-thick panels, the combustibility was the largest in lauan solid wood followed by medium density fiberboard. particleboard. and plywood. 2. Medium density fiberboard was burned more easily than plywood in 6mm-thick panels and the higher oxygen concentration was needed as the panel thickness increased. 3. The oxygen indices of 9mm-thick panels were 29.0 in lauan solid wood, 31.4 in medium density fiberboard, 33.0 in particleboard, and 33.4 in plywood and those of 6mm-thick panels were 28.3 in medium density fiberboard and 29.7 in plywood. 4. The rate of weight loss was the largest in lauan solid wood followed by medium density fiberboard, plywood, and particleboard.

  • PDF

Resistance of Wood Plastic Composites Having Silica Filler to Subterranean Termite

  • Aujchariya CHOTIKHUN;Wa Ode Muliastuty ARSYAD;Emilia-Adela SALCA;Yusuf Sudo HADI;Salim HIZIROGLU
    • Journal of the Korean Wood Science and Technology
    • /
    • 제52권4호
    • /
    • pp.331-342
    • /
    • 2024
  • Rubberwood (Hevea brasiliensis) has excellent physical and mechanical properties and is one of the most widely used species in Southeast Asia. However, it has poor resistance to subterranean termite attacks due to its high sugar and starch contents. The objective of this study was to evaluate the termite resistance of experimental wood-plastic composite (WPC) panels manufactured from rubberwood flour, polyethylene terephthalate, and silica in three different weight ratios (1/2/7, 1/3/6, and 1/4/5). The panels were exposed to Coptotermes curvignathus subterranean termites in a no-choice test under laboratory conditions based on Indonesian standards. Solid rubberwood used as control samples presented poor resistance, exhibiting 23.1% weight loss due to subterranean termite attack, as indicated by low termite mortality and high wood weight loss. In contrast, the WPC samples demonstrated extreme resistance, with weight loss ranging from 0.19% to 0.23%. Based on the findings of this study, the high termite mortality and overall low mass loss of the samples indicate that such manufactured panels could provide a high level of protection with regard to Indonesian standards.

Simultaneous Improvement of Formaldehyde Emission and Adhesion of Medium-Density Fiberboard Bonded with Low-Molar Ratio Urea-Formaldehyde Resins Modified with Nanoclay

  • WIBOWO, Eko Setio;LUBIS, Muhammad Adly Rahandi;PARK, Byung-Dae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제49권5호
    • /
    • pp.453-461
    • /
    • 2021
  • In wood-based composite panels, low-molar ratio (LMR) urea-formaldehyde (UF) resins usually result in reduced formaldehyde emission (FE) at the expense of poor adhesion. However, the FE and adhesion of medium-density fiberboard (MDF) bonded with LMR UF resins were both improved in this study. The modified LMR UF resins with transition metal ion-modified bentonite (TMI-BNT) nanoclay simultaneously improved the FE and adhesion of MDF panels. The modified LMR UF resins with 5% TMI-BNT resulted in a 37.1% FE reduction and 102.6% increase in the internal bonding (IB) strength of MDF panels. Furthermore, thickness swelling and water absorption also significantly decreased to 13.0% and 24.9%, respectively. These results imply that TMI-BNT modification of LMR UF resins could enhance the formation of a three-dimensional network rather than crystalline domains, resulting in improved cohesion.

은수원사시나무와 저밀도 폴리에틸렌으로 제조된 목질플라스틱패널의 성능 (Performance of Wood-plastic Panel Made from Populus alba × glandulosa and Low Density Polyethylene)

  • 곽준혁;오용성
    • Journal of the Korean Wood Science and Technology
    • /
    • 제32권1호
    • /
    • pp.67-72
    • /
    • 2004
  • 은수원사시나무 파티클과 저밀도 폴리에틸렌을 50:50, 60:40, 70:30의 3종류 혼합비율로 열압온도 145℃와 열압시간 5분에서 목질플라스틱패널을 제조하였다. 본 연구에서 목질플라스틱패널을 제조하는데 왁스와 접착제 등 어떤 첨가제도 사용하지 않았다. 제조한 목질플라스틱패널의 밀도, 박리강도, 휨탄성계수, 휨파괴계수, 두께팽창률 및 물흡수율에 대한 성질을 측정하여 패널의 성능을 평가하였다. 성능평가한 data를 SAS programing package에 의해 통계분석한 결과에 의하면 목질플라스틱패널의 박리강도, 휨파괴계수 등의 성질은 목재/폴리에틸렌 혼합비율이 50:50으로 제조된 패널이 다른 혼합비율인 60:40과 70:30으로 제조된 패널보다 5% 수준에서 높게 나타났다. 목질플라스틱패널의 치수안정화를 기준으로 볼 때, 목재/폴리에틸렌 최적의 혼합 비율이 60:40이라는 결과를 보여줬다.

목질제품에서 방출되는 휘발성 유기화합물 특성 연구 (Characteristics of Volatile Organic Compounds Emitted from Wood-based Panels)

  • 박현주;손윤석;임보아;김조천;박상범
    • 한국대기환경학회지
    • /
    • 제26권6호
    • /
    • pp.616-623
    • /
    • 2010
  • Recently, interests in indoor air quality (IAQ) have been increased; however, a number of researchers have mainly focused on anthropogenic volatile organic compounds (AVOC) emitted from building materials. Therefore, the properties of natural VOC (NVOC) and anthropogenic VOC (AVOC) emitted from wood-based panels was investigated in this work. VOCs emitted from these panels were sampled through Tenax TA/Cabotrap and analyzed by GC-MS and GC-FID. Comparisons were made concerning TVOC, NVOC, and composition ratios of NVOC. It was revealed that TVOC emission rates of midium density fiber (MDF) were the highest. Besides, it was found that emissions of NVOC from wood-based panels were much higher than those of anthropogenic AVOC except for plywood of Oceania timber. It was also observed that the composition ratio of NVOC emitted from plywood of Pinus radiata was the highest as 65% of TVOC. Major NVOC components were monoterpene compounds such as $\alpha$-pinene, $\beta$-pinene, d-limonene, camphene and $\alpha$-terpinene. It was concluded that the composition rates of VOCs emitted from building materials were clearly different according to the raw materials and manufacturing methods.

목질.시멘트보드의 물리.기계적 성질, 열전도성 및 내화성 (Physical and Mechanical Properties, Thermal Conductivity and Fire-Proof Performance of Wood-Cement Board)

  • 서진석;박종영
    • 한국가구학회지
    • /
    • 제14권2호
    • /
    • pp.31-38
    • /
    • 2003
  • This study was carried out to investigate characteristics of wood-based panels and wood-cement board for the possible uses as flooring and wall materials. The optimum cement/wood ratio(C/W ratio) of wood~cement board manufactured by clamp-pressing was from 2.7 to 3.2. The dimesional stability was superior in the C/W ratio of 3.2. Particularly, the dimensional stability of cement board using fine particle for particleboard face layer was favorable through three levels of C/W ratio. According to types of wooden material, bending strength of cement board using coarse particle for particleboard core layer or old newspaper(ONP) fiber was relatively higher than others. Thermal conductivities of wood-cement boards were no lower than that of gypsum board, and higher than those of plywood and boards. In case of wood-cement board of the C/W ratio of 2.7, the fire-proof performances of cement composite boards were greater than that of gypsum board, and weight loss reached to about a half of gypsum board. Then, wood-cement boards showed superior fire-proof performance compared to wood-based panels.

  • PDF