• Title/Summary/Keyword: wireless remote

Search Result 771, Processing Time 0.029 seconds

The Development of Offshore Wind Resource Measurement System and Remote Monitoring System (해상기상관측 시스템 및 실시간 원격 모니터링시스템 개발)

  • Ko, Suk-Whan;Jang, Moon-Seok;Lee, Youn-Seop
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.72-77
    • /
    • 2011
  • The purpose for installation of offshore weather station is a measurement of wind resources and so on. If weather station is operated, it will be possible to analysis for wind resource and arrangement of wind farm by using measured data. In this paper, we carried out the development of offshore wind resource measurement system for measuring offshore wind resource. Also, In order to monitor for real-time wind data with 1 Hz, we installed the wireless transmission system. All wind characteristic data are sent to the server PC through the this system is connected outport of DataLogger. Transmitted wind data were used in order to look at in the Web-page and tablet PC on a real time basis in a graph. In this paper, we will introduce about the wind resource measurement and remote monitoring system that is the result of study.

Design and Implementation of Mobile Remote Control System for Management of Distributed Systems in Wireless Environment (무선 환경에서 분산 시스템 관리를 위한 모바일 원격 제어 시스템의 설계 및 구현)

  • Heo, Ji-Hoon;Seo, Jung-Hee;Park, Hung-Bok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.520-523
    • /
    • 2005
  • As the Internet business has been growing rapidly, Internet users or Internet service providers have requested stable service. Along with them, the protection of data such as the management of computer information system and the prevention of barriers has become an important element. This study has embodied the remote control system that manages the scattered resources and service using JMX (Java Management Extensions) in the mobile environment and it has also suggest the method of connecting it with the remote terminal. Through the system suggested in this study, system managers are able to manage the system safely through their own regardless of time and space with the aid of mobile phone.

  • PDF

Analysis of Secure Remote Access to Virtual Private Home Network with L2TP Tunneling methods (L2TP tunneling 방법을 기반으로 한 가설 사설망의 보안 원격 접속분석)

  • Basukala, Roja Kiran;Choi, Dong-You;Han, Seung-Jo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.12
    • /
    • pp.2188-2194
    • /
    • 2008
  • Home network is the connection and communication of several electronic and electrical devices at hone with the integration of several technologies like Ethernet, wireless, phone line and power-line at the residential gateway to the internet. This internet based home network can be accessed from any part of the world through any device by any poison via internet. Since home network is developed for comfortable and safe life of home users, the information flow to/from home network needs to be private. Hence the remote access of the home network must be secured. This paper analyses two secure tunneling methods, voluntary and compulsory for L2TP(Layer Two Tunneling Protocol) based VPN(Virtual Private Network) for secure remote access of the home network.

Study on the Optimal Design of Automatic Data Recovery System in case of Communication Loss in Remote Management of Hydraulic Facilities (수리시설물 원격관리에 있어 통신두절시 데이터 자동복구 시스템 최적설계에 관한 연구)

  • Ahn, Tae-Hyung;Kim, Sang-Yu;Ko, Jeong-Min;Kim, Jae-Yeol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.4
    • /
    • pp.46-52
    • /
    • 2022
  • In the existing wired communication network, wired communication is frequently interrupted by lightning, which accompanies rain, and remote management cannot be performed when it is actually necessary. In the case of communication interruption, field data stored in the database are lost, and data at an important point in time may go missing; this causes a decrease in the reliability of the stored data. Therefore, in this study, wireless communication using the Internet of Things (IoT) communication network of the 4th industrial technology is installed in the prototype to reduce wired communication construction costs, prevent resource waste and environmental damage due to communication facility construction, and prepare for communication loss.

Remote medical Smart healthcare system for IoT-based multi-biometric information measurement (IoT기반 다중 생체정보 측정을 위한 원격 의료 스마트 헬스케어 시스템)

  • Sim, Joung-Yong;Seo, Hyun-Gon
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.53-61
    • /
    • 2020
  • Recently, as the uncontact service is activated in earnest due to the Corona 19 virus, the necessity of system development to provide non-face-to-face contact remote medical service has increased. In this study, we propose a smart healthcare system, Rm_She(Remote Medical Smart Healthcare System). Rm_She can collect and manage various vital signs information by connecting various healthcare products that detect bio-signals based on IoT to one application. The health check app (HC_app) is used to connect vital sign measurement devices to a wireless LAN and receive vital sign values from the HC_app. Then, the vital signs are output to the user on the smartphone, and the corresponding information is transmitted to the healthcare management server. The healthcare server receives the measured values and stores them in a database, and the stored measured values are provided as a web service so that medical staff can remotely monitor them in real time.

Necessity Analysis and Link Budget of Two Way Paging Earth Station for Satellite (양방향 무선호출 위성 지구국 시스템의 필요성 분석 및 위성 링크 설계)

  • Jang, Dae-Ik;Kim, Dae-Yeong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.9
    • /
    • pp.2460-2469
    • /
    • 1999
  • Recently, appearing of various wireless telecommunications services, the competitive power of paging service is requested. In this paper, two-way paging earth station for satellite was proposed and designed to enhance the competitive power of cost and technique, and the link budget of this two-way paging networks using Koreas at was discussed. To reduce the cost of remote station, the antenna and HPA size of Hub and remote station were differently designed, and an idea of power allocations of inbound and outbound carriers was proposed and utilized in this link budget of two-way earth station for using satellite. The results of this link budget were follows. At the 0.043% time rate of rain, antenna size of Hub and remote station were 3.7m and 1.2m, the HPA size of Hub and remote station were 10.37W and 2.0W, and power allocations of outbound and inbound were 84% and 16% respectively. At the 0.02% time rate of rain, the antenna size of Hub and remote station were 3.7m and 1.8m and power allocations of outbound and inbound were 63% and 37% respectively.

  • PDF

Local Control and Remote Optimization for CSTR Wastewater Treatment Systems (CSTR 하.폐수처리장의 국지 제어 및 원격 최적화 시스템)

  • Bae, Hyeon;Seo, Hyun-Yong;Kim, Sung-Shin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.21-25
    • /
    • 2002
  • Activated sludge processes are widely used in biological wastewater treatment processes. The main motivation of this research is to develop an intelligent control strategy for activated sludge process (ASP). ASP is a complex and nonlinear dynamic system because of the characteristic of wastewater, the change in influent rate, weather conditions, and so on. The mathematical model of ASP also includes uncertainties which are ignored or not considered by process engineer or controller designer. The ASP model based on Matlab/Simulink is designed in this paper. The performance of the model is tested by IWA (International Water Association) and COST (European Cooperation in the filed of Scientific and Technical Research) data that include steady-state results during 14 days. In this paper, fuzzy logic control approach is applied to control the DO (dissolved oxygen) concentration. The fuzzy logic controller that includes two inputs and one output can adjust air flowrate. Also, this paper introduces the remote monitoring and control system that is applied for the CSTR (Continuously Stirred Tank Reactor) wastewater treatment system. The CSTR plant has a local control and the remote monitoring system which is contained communication parts which consist of LAN (Local Area Network) network and CDMA (Code Division Multiple Access) wireless module. Remote control and monitoring systems are constructed in the laboratory.

  • PDF

Air Quality Monitoring System Using NDIR-CO$_2$ Sensor for Underground Space based on Wireless Sensor Network (비분산적의선 CO$_2$센서를 이용한 무선 센서 네트워크 기반의 지하 공기질 모니터링 시스템)

  • Kwon, Jong-Won;Kim, Jo-Chun;Kim, Gyu-Sik;Kim, Hie-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.4
    • /
    • pp.28-38
    • /
    • 2009
  • In this study, a remote air quality monitoring system for underground spaces was developed by using NDIR-based CO$_2$ sensor. And the remote monitoring system based on wireless sensor networks was installed practically on the subway station platform. More than 6.5 million citizens commutate everyday by the Seoul subway transportation that is the most typical public transportation. They concern about air quality with increasing interest on public health or many workers in subway stations or underground shopping centers. Recently, the Korean Ministry of Environment has operated the air quality monitoring system in some subway stations for testing phase. However, it showed many defects which are large-scale, high-cost and maintenance of precision sensors imported from abroad. Therefore this research includes the reliability test and a theoretical study about the inexpensive commercialized CO$_2$ sensor for reliable measurement of air quality which changes rapidly by the surrounding environments. And then we develop the wireless sensor nodes and the gateway applied for remote air quality monitoring. In addition, web server program was realized to manage air quality in the subway platform. This result will be valuable for a basic research for air quality management in underground spaces for future study.

Implementation of Inter-vehicle Communication System and Experiments of Longitudinal Vehicle Platoon Control via a Testbed

  • Kim, Tae-Min;Choi, Jae-Weon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.711-716
    • /
    • 2003
  • This study considers the implementation issues of the inter-vehicle communication system for the vehicle platoon experiments via a testbed. The testbed, which consists of three scale vehicles and one RCS(remote control station), is developed as a tool for functions evaluation between simulation studies and full-sized vehicle researches in the previous study. The cooperative communication of the vehicle-to-vehicle or the vehicle-to-roadside plays a key role for keeping the relative spacing of vehicles small in a vehicle platoon. The static platoon control, where the number of vehicles remains constant, is sufficient for the information to be transmitted in the suitably fixed interval, while the dynamic platoon control such as merge or split requires more flexible network architecture for the dynamical coordination of the communication sequence. In this study, the wireless communication device and the reliable protocol of the flexible network architecture are implemented for our testbed, using the low-cost, ISM band transceiver and the 8-bit microcontroller.

  • PDF

An Architecture and Protocol for Mobile Emergency Service

  • Jang Jeong-Ah;Choi Hae-Ock;Choi Wan-sik
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.608-611
    • /
    • 2005
  • The existing wired emergency call such as 119, 112 have its own location information to serving immediate rescue service. For the case of wireless emergency call by mobile phone, the location information should be provided by wireless network. This paper describes the network architecture and protocol for mobile emergency service referring TIAlEWJ-SID-036-A with reviews about technical issues, legacy factors and related researches. The mobile emergency service is divided into mobile emergency rescue service and mobile emergency alert service. The network reference model for mobile emergency rescue service is released in KOREA. In this paper, the interfaces between elements of the network reference model, and service scenarios, message flows are defined. Supplement to mobile emergency rescue service, the network reference model, interfaces and message flows for mobile emergency alert service are developed. The protocol is described by DID, and the proposed works are on processing for domestic standard of TTA.