• Title/Summary/Keyword: winding fault

Search Result 258, Processing Time 0.031 seconds

Development of Asynchronous Blocking Algorithm through Asynchronous Case Study of Steam Turbine Generator (스팀터빈 발전기 비동기 투입 사례연구를 통한 비동기 방지 알고리즘 개발)

  • Lee, Jong-Hweon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1542-1547
    • /
    • 2012
  • Asynchronous phenomenon occurs on the synchronous generators under power system when a generator's amplitude of electromagnetic force, phase angle, frequency and waveform etc become different from those of other synchronous generators which can follow instantly varying speed of turbine. Because the amplitude of electromagnetic force, phase frequency and waveform differ from those of other generators with which are to be put into parallel operation due to the change of excitation condition for load sharing and the sharing load change, if reactive current in the internal circuit circulates among generators, the efficiency varies and the stator winding of generators are overheated by resistance loss. When calculation method of protection settings and logic for protection of generator asynchronization will be recommended, a distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome asynchronizing protection, this paper describes an improved backup protection coordination scheme using a new logic that will be suggested.

Recovery Characteristics of SFCL According to the Turn's Variation (턴수 변화에 따른 초전도 전류제한기의 회복특성 분석)

  • Han, Tae-Hee;Cho, Yong-Sun;Park, Hyoung-Min;Nam, Guong-Hyun;Lee, Na-Young;Choi, Hyo-Sang;Lim, Sung-Hun;Chung, Dong-Chul;Hwang, Jong-Sun;Choi, Myoung-Ho;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.184-185
    • /
    • 2006
  • The flux-lock type superconducting fault current limiter (SFCL) has the attractive characteristics that can adjust the current limiting level by the turns ratio between two coils. Since the recovery characteristics of a superconducting element m the flux-lock type SFCL were dependent on the turns ratio between two coils, the analysis for the recovery characteristics of this type SFCL together with the current limiting characteristic is necessary to apply it to power system. When the applied voltage and load impedance were same, the recovery time of the superconducting element was 0.32sec in case that the turn's ratio between the primary and secondary windings was 63:21. In the meantime, when the turn's ratio of secondary winding increased to 3 times, the recovery time became longer to 0.58sec.

  • PDF

A Study on Protection of Generator Asynchronization by Impedance Relaying (임피던스 계전기를 이용한 발전기 비동기 투입 보호 연구)

  • Lee, Jong-Hweon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.11
    • /
    • pp.2000-2006
    • /
    • 2011
  • Asynchronous phenomenon occurs on the synchronous generators under power system when a generator's amplitude of electromagnetic force, phase angle, frequency and waveform etc become different from those of other synchronous generators which can follow instantly varying speed of turbine. Because the amplitude of electromagnetic force, phase frequency and waveform differ from those of other generators with which are to be put into parallel operation due to the change of excitation condition for load sharing and the sharing load change, if reactive current in the internal circuit circulates among generators, the efficiency varies and the stator winding of generators are overheated by resistance loss. Where calculation method of protection settings and Logic for Protection of Generator Asynchronization will be recommended, A distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, Zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome asynchronizing protection this paper describes an improved backup protection coordination scheme using a new Logic that will be suggested.

A Study of Stator Fault Detection for the Induction Motor Using Axial Magnetic Leakage Flux (축방향 누설자속 측정에 의한 유도전동기의 고정자 결함검출에 관한 연구)

  • Shin, Dae-Cheul;Kim, Young-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.131-137
    • /
    • 2005
  • The purpose of this paper is to evaluate the axial magnetic flux measurement could be used as a tool of the condition monitoring system for the induction motor and to develope the diagnostic algerian for the electric motors. The magnetic leakage flux signal is captured by the flux coil located at the end of motor without the disturbance of the operation. And the signal is analyzed both time and frequency bases to detect the failure of the motor. Specific signature can be described in time and frequency domain for each faults of the motor. The spectrum of the signal was found more useful for the monitoring purpose. The supply voltage imbalance and tin to turn failure of the stator winding could be detected by analysing the specific sidebands of the axial flux and sideband of the rotor bar pass frequency with the high resolution spectrum. The goal of this study verity that the axial flux measurement for the induction motor is a powerful tool for the diagnostic method and develope the algorithm to detect the fault.

Estimation of Motor Deterioration using Pulse Signal and Insulation Resistance Measurement Algorithm (펄스 신호 및 절연저항 측정 알고리즘을 이용한 전동기 열화 추정)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.5
    • /
    • pp.111-116
    • /
    • 2022
  • The causes of motor burnout include overload, phase loss, restraint, interlayer short circuit, winding ground fault, instantaneous overvoltage, and the rotor contacting the stator, leading to insulation breakdown, leading to breakdown or electrical accidents. Therefore, equipment failure causes not only loss due to cost required for equipment maintenance/repair, but also huge economic loss due to productivity decrease due to process stop because the process itself including the motor is stopped. The current level of technology for diagnosing motor failures uses vibration, heat, and power analysis methods, but there is a limit to analyzing the problems only after a considerable amount of time has passed according to the failure. Therefore, in this paper, a device and algorithm for measuring insulation resistance using DC AMP signal was applied to an industrial motor to solve this problem. And by following the insulation resistance state value, we propose a diagnosis of deterioration and failure of the motor that cannot be solved by the existing method.

Wing Technique: A Novel Approach for the Detection of Stator Winding Inter-Turn Short Circuit and Open Circuit Faults in Three Phase Induction Motors

  • Ballal, Makarand Sudhakar;Ballal, Deepali Makarand;Suryawanshi, Hiralal M.;Mishra, Mahesh Kumar
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.208-214
    • /
    • 2012
  • This paper presents a novel approach based on the loci of instantaneous symmetrical components called "Wing Shape" which requires the measurement of three input stator currents and voltages to diagnose interturn insulation faults in three phase induction motors operating under different loading conditions. In this methodology, the effect of unbalanced supply conditions, constructional imbalances and measurement errors are also investigated. The sizes of the wings determine the loading on the motor and the travel of the wings while their areas determine the degree of severity of the faults. This approach is also applied to detect open circuit faults or single phasing conditions in induction motors. In order to validate this method, experimental results are presented for a 5 hp squirrel cage induction motor. The proposed technique helps improve the reliability, efficiency, and safety of the motor system and industrial plant. It also allows maintenance to be performed in a more efficient manner, since the course of action can be determined based on the type and severity of the fault.

Characteristics of a Hybrid-type SFCL with Serial and Parallel Connection of Secondary Circuit (2차회로의 직.병렬연결에 따른 하이브리드형 초전도 한류기의 특성)

  • Cho, Yong-Sun;Park, Hyoung-Min;Nam, Goung-Hyun;Lee, Na-Young;Han, Tae-Hee;Choi, Choi-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.393-395
    • /
    • 2006
  • We investigated the operational characteristics of the hybrid-type superconducting fault current limiter (SFCL) according to the serial and parallel connections of secondary circuits. The hybrid-type SFCL consists of a transformer, which has a primary winding and several secondary windings with $YBa_2Cu_3O_7$ films connected in series and parallel. In order to increase the capacity of the SFCL, the serial connection between each current limiting unit is necessary. The hybrid-type SFCL with the serial connection in secondary circuits could show superior characteristics than those of the parallel connections in the current limiting and quench time. The resistances generated in the superconducting units were also lowered at the parallel connections. We confirmed that the parallel connection reduced the power burden of each superconducting unit under the same conditions because of the simultaneous quenching between superconducting units.

  • PDF

Operational Characteristics of Transformer-Type SFCL with or without Neutral Line between the Secondary windings and Superconducting units (2차 권선과 초전도 사이의 중성선 유무에 따른 변압기형 초전도 한류기의 동작특성)

  • Cho, Yong-Sun;Choi, Hyo-Sang;Go, Sung-Pil
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1268-1273
    • /
    • 2011
  • The study on power capacity increase of superconducting fault current limiter (SFCL) is one of the most important researches to apply a SFCL in the power system. To achieve this, we thought that the unbalanced quenching problem generated in series connection of superconducting units should be solved. In this paper, we investigated the quenching characteristics of superconducting units in the transformer-type SFCL with or without the neutral line between secondary windings and superconducting units. In case of transformer-type SFCL without neutral line, the connection structure of superconducting units is identical to that of the resistive-type SFCL connected in series. Therefore, the unbalanced quenching was occurred by difference of critical current between superconducting units. However, in case of transformer-type SFCL with neutral line, the superconducting units with different critical current were simultaneously quenched. It was because the currents induced by secondary winding were separately flowed through the superconducting units. By these results, we confirmed that the resistances and consumption powers of the superconducting units were equally generated.

A Study Of Reliability Check Method for Generator Field Ground Detectors (발전기 계자 접지 검출회로 신뢰성 점검에 관한 연구)

  • Cheon, Young-Sik;Park, Ho-Chul;Won, Hak-Jai;Han, Seung-Mun;Han, Jeong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.585-587
    • /
    • 1999
  • The rotorbody and rotor winding of generator are isolated by an insulator and the output characteristic of the generator is maintained in the best states. Only when an insulation resistance between them is over a certain extent. The aim of this research is to develop the simulator for rotor earth fault detection circuits. It is composed of the power resource which is to control the virtual field voltage, stepping motor which is to give virtual ground. It is possible to inspect with the device and program developed in this study in the same as real operating condition and evaluate the integrity of generator rotor through the function of data acquisition and graphic output. If these technologies will be applied to the inspection, prevent a damage of the generator and contribute to improve maintenance reliance.

  • PDF

Characteristics of Hybrid-Type SFCL by the Number of Secondary Windings with YBCO Films (2차회로의 수에 따른 하이브리드형 초전도 한류기의 동작 특성)

  • Cho Yong-Sun;Choi Hyo-Sang;Park Hyoung-Min
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.2
    • /
    • pp.62-66
    • /
    • 2006
  • We investigated the characteristics of the hybrid-type superconducting fault current limiter (SFCL) by the number of secondary windings. The SFCL consists of a transformer, which has a primary winding and several secondary windings with serially connected $YB_{a2}Cu_{3}O_{7}$ films. In order to increase the capacity. of the SFCL, the serial connection between each current limiting unit is necessary. Resistive-type SFCL has a difficulty in quenching simultaneously between the units due to slight differences of their critical current densities. The hybrid-type SFCL could achieve the simultaneous quenching through the electrical isolation and the mutual flux linkage among the units. We confirmed that the capacity of the SFCL could be increased effectively through the simultaneous quenching among the units. In addition, the power burden of the system could be reduced by adjusting the number of secondary windings. We will investigate the method to increase the capacity through serial and Parallel connections among current limiting units.