• Title/Summary/Keyword: winding deformation.

Search Result 47, Processing Time 0.021 seconds

The development of LVI tester for application of transformers winding deformation diagnosis (변압기 권선변형 진단에 적용하기 위한 LVI 시험기 개발)

  • 조국희;김광화
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.97-103
    • /
    • 2002
  • The assessment of the condition of a transformer winding which is suspected of having suffered short circuit damage can be difficult. Conventional test such as winding resistance, magnetic current or insulation resistance will only detect damage if a permanent electrical fault exists. Visual inspection of windings necessitates the removal of oil and in many cases only a very small proportion of the winding can be seen. We describe the characteristic of LVI test system and methods to detect the deformation of windings in the power transformers. As the front rise time of recurrent-surge generator pulse less than 1000 ㎱ and the peak value of pulse is about 500 V, we have the good results of detecting winding deformation in the LVI test of transformers.

A Study on L.V.I. Diagnosis Field Application of Transformer Winding Deformation (변압기 권선변형 L.V.I. 진단 실적용을 위한 연구)

  • Cho, Kook-Hee;Kang, Dong-Sik;Kim, Kwang-Hwa;Kweon, Dong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1638-1640
    • /
    • 1998
  • We describe the possibility of field application and the diagnosis method of winding deformation in the power transformers using L.V.I. test system. Any winding deformation will result in a change of capacitance between winding parts and passibly some change in the winding inductance. These changes will then result in a change in the responce to the applied pulse in both the magnitude and period of the resulting oscillations. And we discuss with respect to test result of model transformer and commercial transformer, appear good results with application possibility in field.

  • PDF

Measurement of winding deformation in transformers using low voltage impulse (저압충격을 이용한 변압기에서 권선변형 측정)

  • Cho, Kook-Hee;Kang, Dong-Sik;Kim, Kwang-Hwa;Kweon, Dong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.388-390
    • /
    • 1997
  • We describe the characteristic of LVI(Low-voltage Impulse) test system and methods to detect the deformation of windings in the power transformers. Any winding deformation will result in a change of capacitance between winding parts and possibly some change in the winding inductance. These changes will then result in a change in the responce to the applied pulse in both the magnitude and period of the resulting oscillations. A results of measured differential method in stead of typical method, the sensitivity is greatly improved by the use of differential methods where the pulse is applied to two identical windings and the response measured with a differential amplifier.

  • PDF

The Development of LVI Tester for WInding Deformation Measurement in Power Transformers (변압기의 권선변형 검증을 위한 LVI 시험기 개발)

  • 조국희;김광화;곽희로
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.251-256
    • /
    • 2000
  • The assessment of the condition of a transformer winding which is suspected of having suffered short circuit damage can be difficult. Conventional test such as winding resistance, magnetisation current or insulation resistance will only detect damage if a permanent electrical fault exists. Visual inspection of windings necessitates the removal of oil and in many cases only a very small proportion of the winding can be seen. We describe the characteristics. As the front rise time of recurrent-surge generator pulse less than 1000ns and the peak value of pulse is about 500V, we have the good results of detecting winding deformation in the LVI test of transformers.

  • PDF

A study on the development of LVI tester and applying the winding deformation of transformers with this tester (LVI 시험기의 개발과 변압기 권선변형 분석의 적용에 관한 연구)

  • 조국희;김광화
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.58-64
    • /
    • 2001
  • This paper is described about design and manufacture of the LVI tester and the model transformer. And we develope the analysis technology of the LVI test with using the developed LVI tester and the model transformer. The LVI tester is consisted of a main body, terminal boxes and cables. It is estimated that the tester has output characteristic to match ANSI specification. The winding deformation models are made of model transformer having tapes and we discuss about the analysis technology of LVI test using the tester and the model transformer.

  • PDF

Prediction of Change in Equivalent Circuit Parameters of Transformer Winding Due to Axial Deformation using Sweep Frequency Response Analysis

  • Sathya, M. Arul;Usa, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.983-989
    • /
    • 2015
  • Power transformer is one of the major and key apparatus in electric power system. Monitoring and diagnosis of transformer fault is necessary for improving the life period of transformer. The failures caused by short circuits are one of the causes of transformer outages. The short circuit currents induce excessive forces in the transformer windings which result in winding deformation affecting the mechanical and electrical characteristics of the winding. In the present work, a transformer producing only the radial flux under short circuit is considered. The corresponding axial displacement profile of the windings is computed using Finite Element Method based transient structural analysis and thus obtained displacements are compared with the experimental result. The change in inter disc capacitance and mutual inductance of the deformed windings due to different short circuit currents are computed using Finite Element Method based field analyses and the corresponding Sweep Frequency Responses are computed using the modified electrical equivalent circuit. From the change in the first resonant frequency, the winding movement can be quantified which will be useful for estimating the mechanical withstand capability of the winding for different short circuit currents in the design stage itself.

Properties of Composite Bushing with Filament Winding Tension (필라멘트 와인딩 장력에 따른 Composite Bushing의 특성에 관한 연구)

  • Cho, Han-Goo;Kim, Kwang-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.34-34
    • /
    • 2010
  • This paper describes effect of the bending deformation of high voltage composite bushing with winding tension. The composite bushing can be formed, by adding silicone rubber sheds to a tube of composite materials. The FRP tube is internal insulating part of a composite bushing and is designed to ensure the mechanical characteristics. Generally the properties of FRP tube can be influenced by the winding angle, wall thickness and winding tension. As winding tension is increased glass contents was increased in the range of 70.4~76.6%. In the bending test, winding tension is increased residual deflection was decreased in the range of 14.0~12.2 mm.

  • PDF

Winding Deformation Measurement using Low-voltage Impulse Tester in Transformers (변압기에서 저압충격시험기를 이용한 권선변형 측정)

  • Cho, Kook-Hee;Kang, Dong-Sik;Kim, Kwang-Hwa;Kweon, Dong-Jin;Yoon, Jin-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1737-1739
    • /
    • 1997
  • We describe the characteristic of LVI test system and methods to detect the deformation of windings in the power transformers. As the front rise time of recurrent-surge generator pulse less than 1000ns and the peak value of pulse is about 500V, we have the good results of detecting winding deformation in the LVI test of transformer. And we discuss the application of LVI test method and the condition of RSG pulse through results of in one and three pole transformers under Lab. tests.

  • PDF

Fault Discrimination of Power Transformers using Vibration Signal Analysis (진동 신호 분석을 이용한 전력용 변압기의 고장 판별)

  • Yoon, Yong-Han;You, Chi-Hyoung;Kim, Jae-Chul;Chung, Chan-Soo;Lee, Jung-Jin
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • In power transformers, vibration signals can occur at winding and core due to the change of current, voltage, and temperature and the deformation of winding and core. The deformation of winding and core occurs electromagnetic force induced by fault current in power systems. There firem the changes of vibration signals can be very different in normal or fault states of power transformers. We edtect and analyze the changes of vibration signals and use them as a tool for fault diagnosis of power transformers. This paper presents fault discriminating polliblility using the changes of fundamental waves and higher harmonics in power transformers. We showed the fault discriminating functions that are made at each case ; normal state and fault state. These functions are tested by the detected vibration signals, and we showed that the proposed method can discriminate the state of power transformers.

  • PDF

Harmonic Reduction of Synchronous Generator by Permanent Magnet Shape Deformation (영구자석 형상 변형을 통한 동기발전기 고조파 저감)

  • Beom-Seok, Byeon;Eui-Jong, Park;Yong-Jae, Kim
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.6
    • /
    • pp.1081-1088
    • /
    • 2022
  • The harmonics of synchronous generators increase iron and copper loss, which is the cause of fever. For harmonic reduction, the armature winding method is used as a distribution winding, a short pitch winding. In this paper, we want to improve the waveform of the instrument voltage by reducing the harmonics in a new way to the shape of the permanent magnet. The method cuts both ends of the permanent magnet and adjusts the air gap by increasing and decreasing the area according to the set value. By varying the distribution of magnetic flux density, the resulting electromotive voltage and strain were compared. This compares the shape-changing models of permanent magnets and shows an effective deformation method.