• Title/Summary/Keyword: wind tower

Search Result 563, Processing Time 0.028 seconds

Aerodynamic performance evaluation of different cable-stayed bridges with composite decks

  • Zhou, Rui;Ge, Yaojun;Yang, Yongxin;Du, Yanliang;Zhang, Lihai
    • Steel and Composite Structures
    • /
    • v.34 no.5
    • /
    • pp.699-713
    • /
    • 2020
  • The aerodynamic performance of long-span cable-stayed bridges is much dependent on its geometrical configuration and countermeasure strategies. In present study, the aerodynamic performance of three composite cable-stayed bridges with different tower configurations and passive aerodynamic countermeasure strategies is systematically investigated by conducting a series of wind tunnel tests in conjunction with theoretical analysis. The structural characteristics of three composite bridges were firstly introduced, and then their stationary aerodynamic performance and wind-vibration performance (i.e., flutter performance, VIV performance and buffeting responses) were analyzed, respectively. The results show that the bridge with three symmetric towers (i.e., Bridge I) has the lowest natural frequencies among the three bridges, while the bridge with two symmetric towers (i.e., Bridge II) has the highest natural frequencies. Furthermore, the Bridge II has better stationary aerodynamic performance compared to two other bridges due to its relatively large drag force and lift moment coefficients, and the improvement in stationary aerodynamic performance resulting from the application of different countermeasures is limited. In contrast, it demonstrates that the application of both downward vertical central stabilizers (UDVCS) and horizontal guide plates (HGP) could potentially significantly improve the flutter and vortex-induced vibration (VIV) performance of the bridge with two asymmetric towers (i.e., Bridge III), while the combination of vertical interquartile stabilizers (VIS) and airflow-depressing boards (ADB) has the capacity of improving the VIV performance of Bridge II.

Electrical and Mechanical Noise Study of the 765kV Transmission Line (765kV 송전선로의 전기적 및 기계적 소음고찰)

  • Lee,
    • Journal of KSNVE
    • /
    • v.6 no.1
    • /
    • pp.89-95
    • /
    • 1996
  • If the transmission line voltage is greater than 500kV, audible noise (AN) and hum noise (HN) due to corona discharges on the conductor would be an important design factor for the conductor selection of transmission line. Also there is an aeolian noise: wind noise(WN) from the tower and the conductor due to wind. This paper presents the results of a statistical analysis of audible noise, hum noise, aeolian noise of 6-480mm$^{2}$ conductor bundle in KEPRI 765kV Test Transmission Line which was constructed to develop 765kV double circuit AC transmission line for the first time in the world. The result of the analysis shows that 6-480mm$^{2}$ conductor bundle and tower satisfy configuration the audible noise design criterion of 50dB(A).

  • PDF

An Analysis on Micro-climate Characteristic of Apartments in Beijing, China Using ENVI-met Simulation (ENVI-met를 이용한 중국 베이징 아파트 하절기 미기후 특성 분석)

  • Wu, Jin-Dong;Lee, Jun-Hoo;Yoon, Seong-Hwan
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.8
    • /
    • pp.169-176
    • /
    • 2019
  • The purpose of this study was to analyze outdoor thermal comfort of apartments planning characteristic of pedestrian height in Beijing, China. Selecting 322 apartment complexes with more than 1000 households and more than 10 buildings(including 10 buildings), mainly in Chaoyang District and Tongzhou District to select 32 basic layout types and then 12 typical layout types were select in 32 basic layout types. Finally, the simulation was conducted for the 12 typical layout types using the micro-climate model ENVI-met to evaluate the wind environment, the thermal environment and the comfort. The results of this study as follows: In the parallel arrangement, it has the best outdoor thermal comfort of Slab-East-Parallel(S/E/P). Next is Slab-South-Parallel(S/S/P), Tower-South-Parallel(T/S/P) in turn. In the stagger arrangement, Mixture-South-North and South Stagger-1(M/S/NSS-1) has the best outdoor thermal comfort and Slab-South-North and South Stagger(S/S/NSS), Tower-South-North and South Stagger(T/S/NSS), Mixture-South-North and South Stagger-3(M/S/NSS-3), Mixture-South-North and South Stagger-4(M/S/NSS-4), Mixture-South-North and South Stagger-2(M/S/NSS-2) in turn. In the cluster arrangement, Mixture-Mixture-Cluster-2(M/M/C-2) has the best outdoor thermal comfort and Mixture-Mixture-Cluster-3(M/M/C-3), Mixture-Mixture-Cluster-1(M/M/C-1) in turn. Due to the low wind speed and high air temperature, it is necessary to consider the layout types that can form the wind road at first, such as Mixture-South-North and South Stagger-1(M/S/NSS-1), Slab-South-North and South Stagger(S/S/NSS) and so on.

Development of Hold on Swing a Jumper Support String for Overhead Transmission Line (송전선로 점퍼선 횡진방지용 지지애자장치 개발)

  • Baik, Seung-Do;Min, Byeong-Wook;Wi, Hwa-Bog;Park, Kee-Yong;Keum, Eui-Yeon;Jeong, Heon-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.521-523
    • /
    • 2005
  • A Jumper wire is currently used to connect each fixed power line on both sides of dead end tower for overhead transmission line, but in case of a jumper wire swing under circumstances of typhoon, etc. and the air clearance is deficient then a flashover fault may Happen. Now the angle tower has the jumper support string to prevent a swing of jumper wire and to secure the air clearance between jumper wire and tower main body, but the flashover fault by swing of jumper wire was happened yl times across all over the country, because of the typhoon 'Rusa' in year 2002 and 'Maemi' in year 2003. This paper presents the design and development of 'Counter Weight' which enables to keep the swing angle of jumper wire under 40 degree in design condition to prevent a flashover fault by swing of jumper wire by a high wind pressure load in case of typhoon and have completed a mechanical and electrical characteristic test.

  • PDF

Design and application of a novel eddy current damper for a high-rise sightseeing tower

  • Kaifang Liu;Yanhui Liu;Chia-Ming Chang;Ping Tan
    • Structural Engineering and Mechanics
    • /
    • v.86 no.4
    • /
    • pp.573-587
    • /
    • 2023
  • A conventional tuned mass damper (TMD) provides a passive control option to suppress the structures' wind- or earthquake-induced vibrations. However, excessive displacements of the TMD raise concerns in the practical implementation. Therefore, this study proposes a novel TMD designed for and deployed on a high-rise sightseeing tower. The device consists of an integrated two-way slide rail mount and an eddy current damper (ECD) with a stroke control mechanism. This stroke control mechanism allows the damping coefficient to automatically increase when the stroke reaches a predetermined value, preventing excessive damper displacements during large earthquakes. The corresponding two-stage damping parameters are designed with a variable-thickness copper plate to enable the TMD stroke within a specified range. Thus, this study discusses the detailed design schemes of the device components in TMD. The designed two-stage damping parameters are also numerically verified, and the structural responses with/without the TMD are compared. As seen in the results, the proposed TMD yields effective control authority to limit the acceleration response within a comfort level. In addition, this TMD resolves the spatial availability for the damper movement in high-rise buildings by the controllable damping mechanism.

A Study on a Wind Turbine Data Logger System based on WiFi for Meteorological Resource Measurement (기상자원 측정을 위한 와이파이 기반의 풍력용 데이터로거 시스템에 관한 연구)

  • Jung, Se-Hoon;Sim, Chun-Bo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.1
    • /
    • pp.55-64
    • /
    • 2015
  • Wind turbine market is showed height growth rate of about 30% for year, and is increasingly growing. Total rate of domestic wind turbine installation is showing share of 0.2% of the global market that is 380MW. However, wind turbine installed in domestic are foreign product more than 90%. Similarly, Datalogger of pretest system for ocean wind turbine plant installation has been leaked huge cost to abroad by mostly abroad company product. In this paper, we proposed pretest weather resource measurement system for efficiency and investment cost cutting of wind turbine construction work. Preset weather resource measurement system is ocean weather resource measurement datalogger based on wireless communication(wifi) that have consist of hardware and software(wind rose) that is able to monitoring as datalogger of wireless bridge and battery state, wind direction, wind speed, temperature, humidity, radiation around weather tower and is able to analysis of measured data.

A wireless high-frequency anemometer instrumentation system for field measurements

  • Huang, Guoqing;Peng, Liuliu;Su, Yanwen;Liao, Haili;Li, Mingshui
    • Wind and Structures
    • /
    • v.20 no.6
    • /
    • pp.739-749
    • /
    • 2015
  • Field measurement of wind characteristics is of great significance for the wind engineering community. High-frequency anemometers such as ultrasonic anemometers are widely used to obtain the high-frequency fluctuating wind speed time history. However, conventional instrumentation systems may suffer from low efficiency, non-real time transmission and higher maintenance cost, and thus are not very appropriate in the field measurement of strong winds in remote areas such as mountain valleys. In order to improve the field measurement performance in those remote areas, a wireless high-frequency anemometer instrumentation system for field measurement has been developed. In this paper, the architecture of the proposed instrumentation system, and measured data transmission and treatment will be presented firstly. Then a comparison among existing instrumentation systems and the proposed one is made. It shows that the newly-developed system has considerable advantages. Furthermore, the application of this system to the bridge site located in the mountain valley is discussed. Finally, typical samples of measured data from this area are presented. It can be expected that the proposed system has a great application potential in the wind field measurement for remote areas such as the mountainous or island or coastal area, and hazardous structures such as ultra-voltage transmission tower, due to its real-time transmission, low cost and no manual collection of data and convenience.

Large eddy simulation of wind effects on a super-tall building

  • Huang, Shenghong;Li, Q.S.
    • Wind and Structures
    • /
    • v.13 no.6
    • /
    • pp.557-580
    • /
    • 2010
  • A new inflow turbulence generation method and a combined dynamic SGS model recently developed by the authors were applied to evaluate the wind effects on 508 m high Taipei 101 Tower. Unlike the majority of the past studies on large eddy simulation (LES) of wind effects on tall buildings, the present numerical simulations were conducted for the full-scale tall building with Reynolds number greater than $10^8$. The inflow turbulent flow field was generated based on the new method called discretizing and synthesizing of random flow generation technique (DSRFG) with a prominent feature that the generated wind velocity fluctuations satisfy any target spectrum and target profiles of turbulence intensity and turbulence integral length scale. The new dynamic SGS model takes both advantages of one-equation SGS model and a dynamic production term without test-filtering operation, which is particular suitable to relative coarse grid situations and high Reynolds number flows. The results of comparative investigations with and without generation of inflow turbulence show that: (1) proper simulation of an inflow turbulent field is essential in accurate evaluation of dynamic wind loads on a tall building and the prescribed inflow turbulence characteristics can be adequately imposed on the inflow boundary by the DSRFG method; (2) the DSRFG can generate a large number of random vortex-like patterns in oncoming flow, leading to good agreements of both mean and dynamic forces with wind tunnel test results; (3) The dynamic mechanism of the adopted SGS model behaves adequately in the present LES and its integration with the DSRFG technique can provide satisfactory predictions of the wind effects on the super-tall building.

Design Load Case Analysis and Comparison for a 5MW Offwhore Wind Turbine Using FAST, GH Bladed and CFD Method (FAST, GH Bladed 및 CFD기법을 이용한 5MW 해상풍력터빈 시스템 설계하중조건 해석 및 비교)

  • Kim, Ki-Ha;Kim, Dong-Hyun;Kwak, Young-Seob;Kim, Su-Hyun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.2
    • /
    • pp.14-21
    • /
    • 2015
  • Design lifetime of a wind turbine is required to be at least 20 years. The most important step to ensure the deign is to evaluate the loads on the wind turbine as accurately as possible. In this study, extreme design load of a offshore wind turbine using Garrad Hassan (GH) Bladed and National Renewable Energy Laboratory (NREL) FAST codes are calculated considering structural dynamic loads. These wind turbine aeroelastic analysis codes are high efficiency for the rapid numerical analysis scheme. But, these codes are mainly based on the mathematical and semi-empirical theories such as unsteady blade element momentum (UBEM) theory, generalized dynamic wake (GDW), dynamic inflow model, dynamic stall model, and tower influence model. Thus, advanced CFD-dynamic coupling method is also applied to conduct cross verification with FAST and GH Bladed codes. If the unsteady characteristics of wind condition are strong, such as extreme design wind condition, it is possible to occur the error in analysis results. The NREL 5 MW offshore wind turbine model as a benchmark case is practically considered for the comparison of calculated designed loads. Computational analyses for typical design load conditions such as normal turbulence model (NTM), normal wind profile (NWP), extreme operation gust (EOG), and extreme direction change (EDC) have been conducted and those results are quantitatively compared with each other. It is importantly shown that there are somewhat differences as maximum amount of 18% among numerical tools depending on the design load cases.

A Simple Ensemble Prediction System for Wind Power Forecasting - Evaluation by Typhoon Bolaven Case - (풍력예보를 위한 단순 앙상블예측시스템 - 태풍 볼라벤 사례를 통한 평가 -)

  • Kim, Jin-Young;Kim, Hyun-Goo;Kang, Yong-Heack;Yun, Chang-Yeol;Kim, Ji-Young;Lee, Jun-Shin
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.1
    • /
    • pp.27-37
    • /
    • 2016
  • A simple but practical Ensemble Prediction System(EPS) for wind power forecasting was developed and evaluated using the measurement of the offshore meteorological tower, HeMOSU-1(Herald of Meteorological and Oceanographic Special Unite-1) installed at the Southwest Offshore in South Korea. The EPS developed by the Korea Institute of Energy Research is based on a simple ensemble mean of two Numerical Weather Prediction(NWP) models, WRF-NMM and WRF-ARW. In addition, the Kalman Filter is applied for real-time quality improvement of wind ensembles. All forecasts with EPS were analyzed in comparison with the HeMOSU-1 measurements at 97 m above sea level during Typhoon Bolaven episode in August 2012. The results indicate that EPS was in the best agreement with the in-situ measurement regarding (peak) wind speed and cut-out speed incidence. The RMSE of wind speed was 1.44 m/s while the incidence time lag of cut-out wind speed was 0 hour, which means that the EPS properly predicted a development and its movement. The duration of cut-out wind speed period by the EPS was also acceptable. This study is anticipated to provide a useful quantitative guide and information for a large-scale offshore wind farm operation in the decision making of wind turbine control especially during a typhoon episode.