• 제목/요약/키워드: wind power inverter

검색결과 131건 처리시간 0.032초

동력저장장치가 적용된 복합발전시스템의 개발 (Development of combined generation systems that power storage apparatus is applied)

  • 이정일;서장수;강병복;차인수
    • 전기학회논문지P
    • /
    • 제51권4호
    • /
    • pp.169-174
    • /
    • 2002
  • The developments of the solar and the wind power energy are neccessary since the future alternative energies that have no pollution and no limitation are restricted. Currently power generation system of existing problems, combined generation system of photovoltaic(400W) and wind power generation system(400W) was suggested. It combines wind power and solar energy to have the supporting effect from each other. However, weather condition, power compensation device that uses elastic energy of spiral spring to combined generation system was also added for the present study. In an experiment, when output of system gets lower than 12V(charging voltage), power was continuously supplied to load through the inverter by charging energy obtained from generating rotary energy of spiral spring operates in small scale generator.

계통연계형 소형풍력발전 시스템의 직렬운전을 고려한 개선된 MPPT 방법 (Advanced Maximum Power Point Tracking Method for the Series Operation Strategy of Grid-Connected Small Wind Turbines)

  • 김용휴;허홍준;김장목
    • 전력전자학회논문지
    • /
    • 제21권6호
    • /
    • pp.497-505
    • /
    • 2016
  • Operating wind turbine generators at maximum power point requires maximum power point tracking (MPPT) control methods. However, conventional methods cannot track the appropriate maximum power point in situations involving wind turbine systems based on a series operation strategy. These systems comprise one or more local maximum power points, and conventional methods can detect only one local maximum power point closed by a current operation point. This study proposes an advanced MPPT method for the series operation strategy of a small, grid-connected wind turbine system. In determining the appropriate maximum point, operations at certain local maximum power points are analyzed. The results show one appropriate point, which is tracked by the proposed MPPT method. The effectiveness of the proposed method is verified by the experimental results.

3상 고압 전력연계를 위한 다중레벨 인버터 (Multi-level PWM Inverter for 3-Phase High Voltage Power On-Grid)

  • 안현진;이화춘;송성근;이상훈;박성준;김광헌;임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.562-564
    • /
    • 2008
  • This paper deals with the three phase high voltage power-grid connection topology using multi-level inverter. Due to the multi-level inverter, these are improved effect of fluctuating voltage, problem of EMC and switching loss using suitable switching patterns of device, above all thing, it is easy to realize the system because of using lower voltage rating switch. This topology can be applicable to power-grid connection of wind system, there is a good point about economical efficiency. The simulation results are presented to verify the validity of the proposed topology.

  • PDF

Application of Fuzzy PI Control Algorithm as Stator Power Controller of a Double-Fed Induction Machine in Wind Power Generation Systems

  • Chung, Gyo-Bum;Choi, Jae-Ho
    • Journal of Power Electronics
    • /
    • 제9권1호
    • /
    • pp.109-116
    • /
    • 2009
  • This paper addresses the output control of a utility-connected double-fed induction machine (DFIM) for wind power generation systems (WPGS). DFIM has a back-to-back converter to control outputs of DFIM driven by the wind turbine for WPGS. To supply commercially the power of WPGS to the grid without any problems related to power quality, the real and reactive powers (PQ) at the stator side of DFIM are strictly controlled at the required level, which in this paper is realized with the Fuzzy PI controller based on the field orientation control. For the Sinusoidal Pulse Width Modulation (SPWM) converter connected to the rotor side of DFIG to maintain the controllability of PQ at the state side of DFIM, the DC voltage of the DC link capacitor is also controlled at a certain level with the conventional Proportion-Integral (PI) controller of the real power. In addition, the power quality at the grid connected to the rotor side of DFIM through the back-to-back converter is maintained in a certain level with a PI controller of the reactive power. The controllers for the PQ at the stator side of DFIM, the DC link voltage of the back-to-back inverter and the reactive power at the grid connected to the rotor side of DFIM are designed and simulated in the PSIM program, of which the result verifies the performance of the proposed controllers.

가변속 풍력발전 시스템의 계통연계 인버터 출력전류 리플 개선에 관한 연구 (Improvement of Output Current Ripple In Grid Connected PWM Inverter for Variable Speed Wind Turbine System)

  • 강신일;송승호;김동용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.369-372
    • /
    • 2003
  • 풍력발전 시스템은 계통에 전력을 공급하는 분산형 전원형태가 대부분이어서 어느 분산형 전원보다 계통 연계시 선로에 미치는 영향이 큰 발전설비이다. 특히 가변속 시스템인 경우 풍속이 낮은 영역에서도 운전이 가능하다는 장점이 있지만 저풍속 영역에서 풍속 변동시 터빈 회전자 출력의 리플이 직류단 전압을 변동하게 만든다. 기존의 직류단 전압 일정제어기를 사용하는 경우 인버터 출력전류는 정현파가 아닌 고조파 리플을 포함하는 문제가 발생한다. 본 논문에서는 이러한 문제점을 해결하고자 직류단 전압에 저역통과 필터를 사용하여 인버터 출력전류의 리플 개선을 하였다.

  • PDF

계통연계형 직렬운전 소형풍력발전시스템의 해석 및 운전방안 연구 (The Analysis and Study on Operation Strategy of Grid-connected Series Small Wind Turbine System)

  • 김창하;구현근;손영득;김장목
    • 전력전자학회논문지
    • /
    • 제20권1호
    • /
    • pp.59-64
    • /
    • 2015
  • This paper proposes an analysis and operation strategy of a grid-connected wind turbine system using a diode rectifier. The currents of generators are the same as that of a small wind turbine system. Therefore, the analysis of generator torque is required as opposed to an analysis of blade speed. In this paper, the appropriate MPPT control method is proposed to control generator torque. Usefulness of the proposed operation strategy is verified by simulations and experiments.

Analysis on the Operational Characteristics of the Combined Generation System with Power Storage Apparatus that Apply Microcontroller

  • Lim, Jung-Yeol;Yoon, Seok-Am;Cha, In-Su
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제12B권1호
    • /
    • pp.24-30
    • /
    • 2002
  • The developments of the solar and the wind power energy are necessary since the future alternative, energies that have no pollution and no limitation are restricted. Currently power generation system of MW scale has been developed, but it still has a flew faults with the weather condition. In order to solve these existing problem combined generation system of photovoltaic(400W) and wind power generation system(400W) was suggested. It combines wind power and solar energy to have the supporting effect from each other. However, since even combined generation system cannot always generate stable output with ever-changing weather condition, power storage apparatus that uses elastic energy of spiral spring to combined generation system was also added far the present study. In an experiment, when output of combined generation system gets lower than 12V(charging voltage), power was continuously supplied to load through the inverter by charging energy obtained from generating rotary energy of spiral spring operates in small scale generator.

계통 연계형 풍력발전 시스템의 고조파 저감 및 무효전력 보상 (Reduction of Harmonics and Compensation of Reactive Power about Wind Power Generation System Connected to Grid)

  • 김영민;황종선;김종만;박현철;송승호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.1093-1096
    • /
    • 2002
  • In this paper, a novel multi voltage inverter system is proposed for reductions of harmonics, which can compensate reactive power. At first, we remove capacitor at input side for reactive power compensation. Secondly, by adding DC voltage to the filter capacitor, it can control power factors as lead-phase according to alterations of loads at power reception. Thirdly, if winding and single phase-bridge inverter(auxiliary circuit) is installed to DC power for reduction of harmonic, waveform of output voltages become to 36-steps. Thus, SVC(static var compensator) systems which can reduce harmonics are designed.

  • PDF

영구자석형 발전기와 계통연계형 인버터의 성능실험 (Performance Testing of the Permanent Magnet Generator and Grid Inverter)

  • 김형길;김철호;서영택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.679-680
    • /
    • 2008
  • Most of the small wind turbines are set as the stand alone type in the area where the access to the grid is difficult and compulsorily uses the battery. Depending on the volume of the battery, securing of the space necessary, and has the shortcoming of replacing the battery periodically due to it's limited working life span. Recently, setting up in the vicinity of the city area is increasing and the trend of using the Grid inverter instead of battery is also increasing. This thesis is aiming mainly analyzing the characteristics of the output power of the Prototype Permanent Magnet Generator(PMG) and the Grid-Inverter and to verify through the theoretical study and tests. Tested the characteristics of the output power of the PMG through the stage 1-2 and at the stage 3 connected the output of the PMG to the Inverter and tested the characteristics of the Inverter. And at the stage 4, the maximum output power is confirmed by the continuous running test of the PMG.

  • PDF

인버터 부착형 농형 유도발전기의 계통고장특성 모의 (Grid faults characteristics simulation of inverter-fed induction generator)

  • 홍지태;권순만;김춘경;이종무;천종민;김홍주;김희제
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.43.1-43.1
    • /
    • 2011
  • The detail simulation modeling of fully-fed induction generator is investigated through PC based MATLAB/Simulink environment. Generator's stator currents are controlled by indirect vector control method. In this method, generator side converter controls the maximum excitation (air gap flux) by stator d-axis current and controls generator torque by stator q-axis current. Induction generator speed is controlled by tip speed ratio (TSR) upon the wind speed variations in order to generate the maximum output power. The generator torque model is specified as a 3-blade wind turbine with rating, then, the model is simulated under normal operating condition and three different fault conditions. The matlab model designed for fully-fed induction generator based wind farm provides good performance under normal and grid fault conditions. It provides good results for different pwm techniques and fault conditions except the single-phase line to ground fault, which should be verified with real time data from wind farms.

  • PDF