• 제목/요약/키워드: width of histogram

검색결과 39건 처리시간 0.026초

Foreign Detection Based on Wavelet Transform Algorithm with Image Analysis Mechanism in the Inner Wall of the Tube

  • Zhu, Jinlong;Yu, Fanhua;Sun, Mingyu;Zhao, Dong;Geng, Qingtian
    • Journal of Information Processing Systems
    • /
    • 제15권1호
    • /
    • pp.34-46
    • /
    • 2019
  • A method for detecting foreign substances in mould based on scatter grams was presented to protect moulds automatically during moulding production. This paper proposes a wavelet transform foreign detection method based on Monte Carlo analysis mechanism to identify foreign objects in the tube. We use the Monte Carlo method to evaluate the image, and obtain the width of the confidence interval by the deviation statistical gray histogram to divide the image type. In order to stabilize the performance of the algorithm, the high-frequency image and the low-frequency image are respectively drawn. By analyzing the position distribution of the pixel gray in the two images, the suspected foreign object region is obtained. The experiments demonstrate the effectiveness of our approach by evaluating the labeled data.

스펙트럼 군집화에서 블록 대각 형태의 유사도 행렬 구성 (Magnifying Block Diagonal Structure for Spectral Clustering)

  • 허경용;김광백;우영운
    • 한국멀티미디어학회논문지
    • /
    • 제11권9호
    • /
    • pp.1302-1309
    • /
    • 2008
  • K-means나 퍼지 군집화와 같은 전통적인 군집화 기법들이 원형(prototype)을 기반으로 하고 볼록한 형태의 집단들에 적합한 반면, 스펙트럼 군집화(spectral clustering)는 국부적인 유사성을 기반으로 전역적인 집단을 찾아내는 기법으로 오목한 형태의 집단들에도 적용할 수 있어 커널을 기반으로 하는 SVM과 더불어 각광을 받고 있다. 하지만 SVM이 그러하듯이 스펙트럼 군집화에서도 커널의 폭은 성능에 지대한 영향을 끼치는 요인으로, 이를 결정하기 위한 다양한 방법이 시도되었지만 여전히 휴리스틱에 의존하는 실정이다. 이 논문에서는 유사도 행렬이 보다 명백한 블록 대각 형태를 가지도록 하기 위해 국부적인 커널의 폭을 거리 히스토그램을 바탕으로 적응적으로 결정하는 방법을 제시한다. 제안한 방법은 스펙트럼 군집화에 사용되는 유사도 행렬(affinity matrix)이 블록 형태의 대각 행렬을 이룰 때 이상적인 결과를 낸다는 사실에 기반하고 있으며, 이를 위해서 전통적인 유클리디안 거리와 무작위 행보 거리(random walk distance)를 함께 사용한다. 제안한 방법은 기존의 방법들에서 사용하는 유사도 행렬에 비해 명확한 블록 대각 행렬을 나타내고 있음을 실험 결과를 통해 확인할 수 있다.

  • PDF

Computed Radiography에서 Additional Filtration Material에 따른 Radiation Dose와 Image Quality의 변화 (Changes of Radiation Dose and Image Quality Due to Additional Filtration Material in Computed Radiography)

  • 권순무;조형욱;강영한;김부순;김정수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권4호
    • /
    • pp.239-246
    • /
    • 2014
  • 필터는 저에너지 X선을 흡수함으로써 평균에너지를 증가시키고, 환자의 피폭선량을 감소시키는 작용을 한다. 본 연구는 Mo과 W 등의 재질이 디지털 방사선영상장치인 CR에서도 사용이 가능한지 SNR, FOM, histogram 등의 영상평가와 선량 측정을 통해 확인하였다. 또한 필터의 재질에 따른 선질측정과 함께 관전압의 변화에 따른 적합한 필터 조합을 찾아보았다. 피부입사선량은 Mo필터가 Cu필터에 비해 42~56%까지 선량 경감효과가 있었고, 투과선량도 Mo필터가 Cu필터보다 1.5배 정도 높게 나타났다. 영상 평가에서 W은 필터로 사용함에 부적절하였으나, Mo은 80 kVp 이상의 관전압에서 영상의 질을 저하시키지 않으면서 선량을 감소시킬 수 있는 필터로 충분히 사용할 수 있음을 확인하였다. 2.0 mmAl+0.1 mmMo은 관전압이 높아질수록 2.0 mmAl + 0.2 mmCu와 histogram width가 거의 같아서, 비교적 높은 관전압인 80, 100, 120 kVp에서는 Mo필터의 사용이 가능하다. 2.0 mmAl + 0.1 mmMo의 SNR은 2.0 mmAl + 0.2 mmCu와 2.0 mmAl+0.1 mmCu의 SNR과도 큰 차이가 나지 않았다. 따라서 디지털 방사선 영상 중 80 kVp 이상을 이용하는 일반촬영에서 Cu를 대신하여 Mo을 필터로 사용하면 Cu에 비해 영상의 질을 저하시키지 않으면서 환자의 피폭선량을 크게 감소시킬 수 있으므로, 실제 임상의 흉부 촬영 및 고관전압 촬영 등에 충분히 적용할 수 있다고 본다.

Transition-based Data Decoding for Optical Camera Communications Using a Rolling Shutter Camera

  • Kim, Byung Wook;Lee, Ji-Hwan;Jung, Sung-Yoon
    • Current Optics and Photonics
    • /
    • 제2권5호
    • /
    • pp.422-430
    • /
    • 2018
  • Rolling shutter operation of CMOS cameras can be utilized in optical camera communications in order to transmit data from an LED to mobile devices such as smart-phones. From temporally modulated light, a spatial flicker pattern is obtained in the captured image, and this is used for signal recovery. Due to the degradation of rolling shutter images caused by light smear, motion blur, and focus blur, the conventional decoding schemes for rolling shutter cameras based on the pattern width for 'OFF' and 'ON' cannot guarantee robust communications performance for practical uses. Aside from conventional techniques, such as polynomial fitting, histogram equalization can be used for blurry light mitigation, but it requires additional computation abilities resulting in burdens on mobile devices. This paper proposes a transition-based decoding scheme for rolling shutter cameras in order to offer simple and robust data decoding in the presence of image degradation. Based on the designed synchronization pulse and modulated data symbols according to the LED dimming level, the decoding process is conducted by observing the transition patterns of two sequential symbol pulses. For this, the extended symbol pulse caused by consecutive symbol pulses with the same level determines whether the second pulse should be included for the next bit decoding or not. The proposed method simply identifies the transition patterns of sequential symbol pulses other than the pattern width of 'OFF' and 'ON' for data decoding, and thus, it is simpler and more accurate. Experimental results ensured that the transition-based decoding scheme is robust even in the presence of blurry lights in the captured image at various dimming levels

토모테라피에서 계획용표적체적 설정 시 필드 폭 영향 분석 (Analysis on the Effect of Field Width in the Delineation of Planning Target Volume for TomoTherapy)

  • 송주영;나병식;정웅기;안성자;남택근;윤미선;정재욱
    • 한국의학물리학회지:의학물리
    • /
    • 제21권4호
    • /
    • pp.323-331
    • /
    • 2010
  • 본 연구에서는 토모테라피 Hi-Art 시스템이 제공하는 3가지(1.0 cm, 2.5 cm, 5.0 cm) 필드 폭 변화에 따른 치료부위 경계면에서의 선량 변화를 조사하여, 필드 폭 크기에 따라 PTV 설정 시 고려되어야 할 사항들을 분석하고자 하였다. 토모테라피 필드 폭 크기에 의한 PTV 양 끝단부 부위의 선량분포 변화를 알아보기 위해 토모테라피 DQA (delivery quality assurance)용 cheesecake 팬텀을 대상으로 각 필드 폭 크기별 토모 치료계획을 수립하여 선량계산 결과와 실제 필름에서의 선량분포를 비교, 분석하였고, 실제 환자를 대상으로 한 치료계획에서도 필드 폭 크기의 영향을 살펴보고자, 복부부위를 치료했던 환자 4명을 대상으로 각 필드 별 치료계획을 세우고, 선량분포를 분석하였다. DQA 팬텀을 대상으로 분석한 결과, 선량계산 값과 조사된 필름분석 결과 모두에서 필드 폭 크기가 커질수록 PTV 양끝단 부위의 선량분포가 더 넓게 분포함을 확인할 수 있었다. Jaw의 폭 변화 방향인 세로(y)방향의 선량분포에서 1.0 cm 필드 크기와 비교하여 최대 선량값 50% 기준으로 2.5 cm 필드는 1.6 cm 더 넓은 선량분포를, 5.0 cm 필드는 4.2 cm 더 넓은 선량분포를 보였다. 실제 환자 데이터를 대상으로 분석한 결과, 4명 모두 필드 폭 크기가 증가함에 따라 PTV y축 양끝 경계면에서 더 많은 선량이 더 넓게 분포함을 알 수 있었다. 특히, 5.0 cm 필드 폭을 사용하였을 경우에는 처방선량에 가까운 높은 선량이 PTV 양끝 상당히 넓은 영역에 걸쳐 조사됨을 알 수 있었으며, 이를 통해 큰 필드 폭을 기준으로 토모테라피 치료계획을 수립할 경우에는 치료기 테이블 진행방향으로 PTV 양끝 경계면에서 기존보다 여유도(margin)를 축소하여 PTV 설정을 하는 것이 타당함을 확인할 수 있었다.

STABLE AUTONOMOUS DRIVING METHOD USING MODIFIED OTSU ALGORITHM

  • Lee, D.E.;Yoo, S.H.;Kim, Y.B.
    • International Journal of Automotive Technology
    • /
    • 제7권2호
    • /
    • pp.227-235
    • /
    • 2006
  • In this paper a robust image processing method with modified Otsu algorithm to recognize the road lane for a real-time controlled autonomous vehicle is presented. The main objective of a proposed method is to drive an autonomous vehicle safely irrespective of road image qualities. For the steering of real-time controlled autonomous vehicle, a detection area is predefined by lane segment, with previously obtained frame data, and the edges are detected on the basis of a lane width. For stable as well as psudo-robust autonomous driving with "good", "shady" or even "bad" road profiles, the variable threshold with modified Otsu algorithm in the image histogram, is utilized to obtain a binary image from each frame. Also Hough transform is utilized to extract the lane segment. Whether the image is "good", "shady" or "bad", always robust and reliable edges are obtained from the algorithms applied in this paper in a real-time basis. For verifying the adaptability of the proposed algorithm, a miniature vehicle with a camera is constructed and tested with various road conditions. Also, various highway road images are analyzed with proposed algorithm to prove its usefulness.

ELA: 가변 형상 구조로봇의 자율주행을 위한 실시간 장애물 회피 기법 (ELA: Real-time Obstacle Avoidance for Autonomous Navigation of Variable Configuration Rescue Robots)

  • 정해관;현경학;김수현;곽윤근
    • 로봇학회논문지
    • /
    • 제3권3호
    • /
    • pp.186-193
    • /
    • 2008
  • We propose a novel real-time obstacle avoidance method for rescue robots. This method, named the ELA(Emergency Level Around), permits the detection of unknown obstacles and avoids collisions while simultaneously steering the mobile robot toward safe position. In the ELA, we consider two sensor modules, PSD(Position Sensitive Detector) infrared sensors taking charge of obstacle detection in short distance and LMS(Laser Measurement System) in long distance respectively. Hence if a robot recognizes an obstacle ahead by PSD infrared sensors first, and judges impossibility to overcome the obstacle based on driving mode decision process, the order of priority is transferred to LMS which collects data of radial distance centered on the robot to avoid the confronted obstacle. After gathering radial information, the ELA algorithm estimates emergency level around a robot and generates a polar histogram based on the emergency level to judge where the optimal free space is. Finally, steering angle is determined to guarantee rotation to randomly direction as well as robot width for safe avoidance. Simulation results from wandering in closed local area which includes various obstacles and different conditions demonstrate the power of the ELA.

  • PDF

전역적 결정트리를 이용한 샷 경계 검출 (Shot Boundary Detection Using Global Decision Tree)

  • 신성윤;문형윤;이양원
    • 한국컴퓨터정보학회논문지
    • /
    • 제13권1호
    • /
    • pp.75-80
    • /
    • 2008
  • 본 논문에서는 프레임들의 차이값으로부터 카메라 브레이크에 의해 발생하는 큰 변화의 폭을 갖는 경계지점을 추출하는 전역적 결정트리를 이용하여 샷 경계를 검출하는 방법을 제시한다. 먼저 지적 $X^2$ 히스토그램과 정규화를 통하여 프레임 간 차이값을 계산하고, 다음으로 차이값간의 거리를 정규화를 통하여 계산한다. 계산된 차이값간의 거리를 바탕으로 전역적 임계치 거리를 계산하여 인접한 두 프레임들에 대한 거리값과 전역적 임계치 거리를 비교하여 샷 경계를 검출한다. 본 논문에서 제시한 전역적 결정트리를 이용하여 객체나 카메라의 움직임과 플래시 라이트와 같은 갑작스런 장면 변화를 쉽게 검출할 수 있다.

  • PDF

토모테라피 Edge 모드를 이용한 임상적 유용성 고찰 (Dosimetric and clinical review on the application of TOMO_edge mode)

  • 김이지
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.177-182
    • /
    • 2014
  • 목 적 : 토모테라피(Tomotherapy)의 두 가지 빔 모드(fixed jaw, dynamic jaw)에 따른 선량 분포 특성과 치료 시간의 차이를 분석하여 dynamic jaw(DJ)를 이용한 Tomo_edge 모드의 임상적 유용성을 고찰하고자 하였다. 대상 및 방법 : 토모테라피를 이용하여 치료받은 환자 7명을 대상으로 임상에서 보편적으로 사용되는 fixed jaw(FJ)를 이용하여 치료 계획을 수립하였다. 각각의 환자에서 모두 동일한 선량계획조건을 부여하였고, 토모테라피의 치료계획 인자인 Modulation Factor(MF), Pitch를 동일하게 유지한 상태에서 1) 동일한 조사면을 적용하고 FJ 와 DJ를 적용한 치료 계획을 비교하였다. 2) FJ를 적용한 치료 계획과 한 단계 큰 조사면과 DJ를 적용한 치료 계획을 비교하였다. 각 실험의 결과는 선량분포의 특성을 확인하기 위하여 종양체적 내 최소값(Dmin)과 선량 조형지수(CI=$V_{95%}$/TV)를 비교하고 표적을 포함한 조사영역 내 체적의 누적선량을 분석하였다. 또한, 임상적 유용성을 확인하기 위하여 빔 조사시간과 MU의 증감을 비교 분석하였다. 결 과 : 동일한 조사면을 적용하고 FJ와 DJ를 적용한 경우, $V_{75%}$은 1.04%, $V_{50%}$은 4.75% 감소하였고, $V_{25%}$은 7.6%, $V_{10%}$은 11.91% 감소하였다. FJ를 적용한 치료계획보다 한 단계 큰 조사면과 DJ를 적용한 경우에 Dmin은 0.72%, CI는 1.25% 줄어들었고, 동일 조사면을 적용한 경우와 마찬가지로 $V_{x%}$는 저선량 영역으로 갈수록 크게 감소하여 $V_{10%}$이 6.13%의 감소 값을 나타냈다. 빔 조사시간과 누적 MU는 동일 조사면 적용 시 각각 3.66%와 3.77%의 값으로 증가하였으나, 한 단계 큰 조사면을 적용한 경우, 빔 조사시간이 31.55%로 누적 MU는 32.28%으로 크게 감소하였음을 보여준다. 결 론 : 동일한 조사면을 사용하면서 DJ를 사용하는 경우, 표적의 선량분포를 거의 변화시키지 않으면서 환자의 용적선량을 효과적으로 감소시킬 수 있었다. 보다 큰 조사면을 사용하는 것과 동시에 DJ를 사용하는 경우는 일부 선량조형성의 저하를 나타내었으나 환자의 용적선량이 감소하고 치료 시간을 감소시킴으로써 Tomo-edge 모드는 임상적으로 유용한 것으로 사료된다.

관상동맥질환 환자에서 방사성동위원소 위상분석에 의한 심근 국소 운동 평가 (Evaluation of Regional Wall Motion by Phase Analysis of Radionuclide Cardiac Blood Pool Scintigrams in Coronary Artery Disease Patients)

  • 이강욱;정준기;오병희;박영배;이명철;이영우;고창순
    • 대한핵의학회지
    • /
    • 제21권2호
    • /
    • pp.167-174
    • /
    • 1987
  • Among noninvasive approaches for the evaluation of left ventricular performance, radionuclide ventriculography (RVG) has been shown to be of particular values. Phase analysis, recently introduced as more objective means for evaluating the temporal sequence of systolic ventricular wall motion than cine image of RVG comprises a pixel by pixel Fourier transformation of the time activity curve of a multiple gated acquisition equilibrium blood pool study. To examine the regional wall motion of ventricles in myocardial infarctions, we evaluated the phase image and histogram constructed for each ventricle by total phase angle range and full width of half maximum (FWHM). This study consisted of 7 normal subjects and 23 subjects with acute myocardial infarction. Contrast ventriculography and coronary angiography was performed in all partients with myocardial infarction. And we compared the result of phase analysis with cine image of RVG and examined the interrelationship between phase analysis and contrast ventriculography with coronary angiography. The results were as follows; 1) The total phase angle range and FWHM of LV phase histogram in myocardial infarction ($86^{\circ}\;and\;32^{\circ}$, repectively) were wider than those in normal control ($38^{\circ}\;and\;18^{\circ}$, respectively p<0.01). 2) RV phase angle range and FWHM in patients with right coronary artery (RCA) occlusion ($79^{\circ}\;and\;37^{\circ}$, respectively) were wider than those in normal control ($39^{\circ}\;and\;18^{\circ}$, respectively p<0.001) and the patients without RCA occlusion ($52^{\circ}\;and\;19^{\circ}$, respectively p<0.01). 3) Phase analysis was more sensitive (95%) than cine image of RVG (70%) for the detection of regional wall motion abnormality of LV.

  • PDF