• Title/Summary/Keyword: width control

Search Result 2,405, Processing Time 0.037 seconds

Dynamic Characteristics of ALA and Active Vibration Control Experiment (ALA 동적 특성 및 능동진동제어 실험)

  • Lee, Han-Dong;Kwak, Moon-K.;Kim, Jeong-Hoon;Song, Yoon-Chul;Shim, Jae-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.8
    • /
    • pp.781-787
    • /
    • 2009
  • This research is concerned with the application of the active linear actuator to the active vibration control of structure. The active linear actuator will be mounted on the sub-frame so that it can cancel the excitation transferred from the engine. Accelerometer mounted on the sub-frame detects the vibration and its signal is fed into the DSP controller where the control algorithm is installed. The output of the DSP controller is connected to the driver which amplifies the DSP output. In general, the pulse width modulation power amplifier is used to drive the voice-coil type actuator. This study shows the dynamic characteristics of the active linear actuator and active vibration control experimental results.

Crack Control in Beams and One-Way Slabs (보 및 1방향 슬래브의 균열제어)

  • Min, Chang-Shik
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.4
    • /
    • pp.381-390
    • /
    • 2012
  • The KCI Building Code (2003 and 2007) provisions to control flexural cracking in beams and one-way slabs are discussed for related researches and the development of the provisions. Based on the basic ideas over the development of current provisions, possible problems with cracking control are identified and discussed for the remedies to fix the problems. Simple and clear equations to control flexural cracking in beams and one-way slabs are presented. The presented equations would avoid any conflicts with other provisions for the spacing of reinforcement.

Active control of delaminated composite shells with piezoelectric sensor/actuator patches

  • Nanda, Namita;Nath, Y.
    • Structural Engineering and Mechanics
    • /
    • v.42 no.2
    • /
    • pp.211-228
    • /
    • 2012
  • Present study deals with the development of finite element based solution methodology to investigate active control of dynamic response of delaminated composite shells with piezoelectric sensors and actuators. The formulation is based on first order shear deformation theory and an eight-noded isoparametric element is used. A coupled piezoelectric-mechanical formulation is used in the development of the constitutive equations. For modeling the delamination, multipoint constraint algorithm is incorporated in the finite element code. A simple negative feedback control algorithm coupling the direct and converse piezoelectric effects is used to actively control the dynamic response of delaminated composite shells in a closed loop employing Newmark's time integration scheme. The validity of the numerical model is demonstrated by comparing the present results with those available in the literature. A number of parametric studies such as the locations of sensor/actuator patches, delamination size and its location, radius of curvature to width ratio, shell types and loading conditions are carried out to understand their effect on the transient response of piezoceramic delaminated composite shells.

Dynamic Investigation of the Brushless DC Motor

  • Sirilappanich, Surachet;Somchaiwong, Nitipong;Pongswatd, Sawai;Ukakimapurn, Prapart
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1867-1870
    • /
    • 2003
  • The analysis and simulation are the method to study the behavior, response, and specification of the driver device. This paper proposes brushless DC drive which using the vector control technique. The encoder is used detect the rotor position and decode to Three-phase step signal. The step signal is modulated with triangle signal and change to the pulse width modulation (PWM) signal. The PWM signal is used for control the input power of the motor based on the vector control technique. The experimental results of the driver circuit and motor response performed under the following condition: as the motor was started, change the load torque, and vary the supply voltage. The experimental performs with a dynamometer and the test results are compared to the simulation method is the same result.

  • PDF

the Shifting Control in Automatic Transmission by Independent-Acting Clutches (클러치의 독립구동에 의한 자동변속기의 변속제어)

  • 김정관;한명철;홍금식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.4
    • /
    • pp.68-84
    • /
    • 2000
  • A study to reduce the transient torque in shifting in automatic transmission has been very important issue. Recently it is really dominant to decrease the torque by using independent-acting hydraulic circuit because we can control the clutch pressure actively and elaborately. So we design the new hydraulic circuit to control the clutches in automatic transmission and make the module library of computer simulations, We apply the results to GM model automatic transmission and carry out 1longrightarrow4 shifting simulations. By this work we recognize the capability of active and elaborate clutch pressure control using new hydraulic circuit. In addition We develop the tool to simulate the powertrain system. It is easier to update and exchange the subsystem model or parameters than conventional simulation tools.

  • PDF

A Variable Hysteresis Control for a DC Bus Conditioner (DC Bus Conditioner을 위한 카변히스테리시스제어)

  • La, Jae-Du;Han, Moon-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.472-475
    • /
    • 2008
  • A DC distributed power system(DPS) has many loads with varied functions. In particular, there may be large pulsed toads with short duty ratio, which can affect the normal operation of other loads. In this paper, a bi-directional converts with inductive storage is used as a DC bus conditioner to damp voltage transients on the bus. In addition, the constant frequency hysteresis control technique for a DC bus conditioner is presented. A simple and fast prediction of the hysteresis band-width is implemented by the phase-lock loop control, keeping constant switching frequency. This technique offers the excellent dynamic response in load or parameter variation. The control performance is illustrated by simulated results with the SABER package. The proposed hysteresis control results in the shortest and the smallest excursions.

  • PDF

Model-Based Predictive Control for Interleaved Multi-Phase DC/DC Converters (다상 인터리브드 DC/DC 컨버터를 위한 모델기반의 예측 제어기법)

  • Choi, Dae-Keun;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.415-421
    • /
    • 2014
  • This study proposes a model-based predictive control for interleaved multi-phase DC/DC converters. The power values necessary to adjust the output voltage in the succeeding are predicted using a converter model. The output power is controlled by selecting the optimal duty cycle. The proposed method does not require controller loops and modulators for converter switching. This method can control the converter by calculating the optimal duty cycle, which minimizes the error between the reference and actual output voltage. The effectiveness of the proposed method is verified through simulations and experiments.

Deadbeat Control of Three-Phase Shunt Active Power Filter Using Resonance Model (공진모델을 이용한 3상 병렬형 능동전력필터의 데드비트제어)

  • Park, Jee-Ho;Kim, Dong-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.3
    • /
    • pp.136-141
    • /
    • 2007
  • In this paper, a new simple control method for active power filter which can realized the complete compensation of the harmonic currents is proposed. In the proposed scheme, a compensating current reference generator employing resonance model implemented by a DSP(Digital Signal Processor) is introduced. Deadbeat control is employed to control the active power filter. The switching pulse width based SVM(Space Vector Modulation) is adopted so that the current of active power filter is been exactly equal to its reference at the next sampling instant. To compensate the computation delay of digital controller, the prediction of current is achieved by the current observer with deadbeat response.

A Study of D.C. Series Motor Control Circuit by Pulsewidth Modulated Chopper (PWM Chopper에 의한 직류직권전동기의 제어회로에 관한 연구)

  • 임달호;장호성
    • 전기의세계
    • /
    • v.26 no.3
    • /
    • pp.76-83
    • /
    • 1977
  • The choice of control method and circuit must be decided after a broad inspection with the characteristics of load and control elements as well as that of electric and mechanical nature. In the present study, Pulse width modulated(PWM) SCR chopper was chosen and for the electric commutation, Jones' forced method was taken bacause of its having enough reverse bias energy. Objectives of experimentation by this system are; 1) the condition of SCR as a gate trigger pulse. 2) the observation of phenomena at the time of forced commutation 3) the experimentation on characteristics of speed control by PWM chopper. Above experimentation shows good characteristics, however, in the limit of narrow gap between the ON and OFF pulses, a complete control was not possible. So, that must be the point to be studied further alone with the harmonics influence.

  • PDF

Fuzzy Controller Design for Fuel Saving in Sun Point Mode for KOMPSAT-2

  • Choi, Hong-Taek;Oh, Shi-Hwan;Rhee, Seung-Wu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2108-2111
    • /
    • 2005
  • The mission life of a satellite determines the amount of fuel required on-board, while the total mass requirement limits the fuel to be loaded. Hence, for the design of thruster control loop, not only the satellite pointing accuracy but the saving of fuel is to be considered. In this paper, a two-step fuzzy controller is proposed for the thruster control loop to save fuel consumption. This approach combines requirements for pointing control accuracy with minimum fuel consumption into a fuzzy controller design. To demonstrate this approach, we have designed a fuzzy controller for the Sun point Mode of KOMPSAT-2. The performance of this fuzzy controller design is compared with that of PD controller used for KOMPSAT-2.

  • PDF