• Title/Summary/Keyword: width control

Search Result 2,405, Processing Time 0.033 seconds

The EFFECTS OF DENTAL LASER ON PULP FIBROBLAST IN VITRO (치과용 레이저 조사가 배양 치수 섬유모세포에 미치는 영향에 관한 연구)

  • Jeong, Hye-Jeon;Min, Byung-Soon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.519-535
    • /
    • 1997
  • The responses of human pulp fibroblastic cells to Ga-As Semi-Conductor-Dens-Bio Laser (Frequency: 5 Hz~10,000 Hz Model: SD-101A RCA, U.SA)) were examined in vitro using pulp fibroblastic cells obtained from the pulp tissue of human tooth. The mitogenic effect of soft laser was assessed by measuring the MTT assay. The morphologic effect for soft laser showed under the scanning and transmission electron microscopy. The results as follows; 1. The mitogenic response of the soft laser was not observed until 4th time of radiation, while the mitogenic response at 4th time increased mitogenic effect by as much as 1.7 fold compared to the control value. 2. The mitogenic response of the soft laser on pulp fibroblast differ from the mitogenic response on other fibroblasts. 3. In scanning electron microscopic study, The microvilli of cell surface increased gradually with width and length after laser radiation, it demonstrate that development of microvilli have close connection with differentiation of cells. 4. Under the transmission electron microscope, The laser-treated cells maintained their elongated shape and a high degree of cellular polarization. The large cell body containing a well developed Golgi complex, a large number of profiles of rough endoplasmic reticulum, and great numbers of mitochondria. 5. The laser-treated cells maintained the long straight bundles of closely apposed microfilaments or individual filaments forming a cross-linked network. These findings suggest that the laser may have important roles in promotion of pulp healing and consequently may be useful for clinical application in pulp regenerative procedures.

  • PDF

Reliability Analysis of Steel Fiber Reinforced Concrete Continuous Beams (강섬유 보강 철근콘크리트 연속보의 신뢰성 해석)

  • Yoo Han-Shin;Jang Hwa-Sup;Kwak Kae-Hwan
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.17 no.4
    • /
    • pp.443-449
    • /
    • 2004
  • Methods for mixing variable types of steel fibers have been developed recently to suppress outbreak of crack or to control the width of crack and improve the load resistible capacity at the same time. On the other hand, uncertainty by complex nature of destruction dynamics of steel fiber reinforced concrete(SFRC) is included. In this study, analysis of reliance considering uncertainty of SFRC beam is done. For this, intensity limit state model was proposed. Moreover, characteristic values about almost every kinds of probability variables were collected and presented according to home and foreign references. Process of improving uncertainty from the result of experiments by Bayseian updating method is also proposed on the purpose of offering better statistical characteristic values with more data in the new future. Fatigue fracture probability equation is proposed and needed statistical characteristic values were presented to analyze fatigue reliance

Management of Permanent Tracheostomal Stenosis by Tracheal Advancement Flap (기관전진피판술을 이용한 영구기관 개구협착의 치료)

  • Choi, Jong-Ouck;Min, Hun-Ki;Choi, Geon;Jung, Kwang-Yoon;Kim, Young-Ho;Park, Chan;Lee, Byeong-Ki
    • Korean Journal of Bronchoesophagology
    • /
    • v.1 no.1
    • /
    • pp.136-141
    • /
    • 1995
  • Tracheostomal stenosis after total laryngectomy is a distressing complication which con-tributes significantly to both psychosocial and physical morbidity according to nature and severity in laryngectomee. Sternal stenosis will compromise not only optimal air exchange, crust formation but also the ability to clear tracheobronchial secretion, so pneumonia and atelectasis will develop. Having a number of procedure recommended for correction of such stenosis with limited results. We developed new technique which is based on tracheal advancement flap had been ap-plied to 12 patients, successfully. We think that total or partial tracheal advancement flap technique Is useful for widening the stoma and advantages of this method are following. 1. Simple technique. possible under local anesthesia 2. Healthy tracheal ring facilities width control 3. Less chance of refractory scar stenosis 4. Tracheoesophageal shunt can be constructed after the partial advancement flap.

  • PDF

A Wide Input Range, 95.4% Power Efficiency DC-DC Buck Converter with a Phase-Locked Loop in 0.18 ㎛ BCD

  • Kim, Hongjin;Park, Young-Jun;Park, Ju-Hyun;Ryu, Ho-Cheol;Pu, Young-Gun;Lee, Minjae;Hwang, Keumcheol;Yang, Younggoo;Lee, Kang-Yoon
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2024-2034
    • /
    • 2016
  • This paper presents a DC-DC buck converter with a Phase-Locked Loop (PLL) that can compensates for power efficiency degradation over a wide input range. Its switching frequency is kept at 2 MHz and the delay difference between the High side driver and the Low side driver can be minimized with respect to Process, Voltage and Temperature (PVT) variations by adopting the PLL. The operation mode of the proposed DC-DC buck converter is automatically changed to Pulse Width Modulation (PWM) or PWM frequency modes according to the load condition (heavy load or light load) while supporting a maximum load current of up to 1.2 A. The PWM frequency mode is used to extend the CCM region under the light load condition for the PWM operation. As a result, high efficiency can be achieved under the light load condition by the PWM frequency mode and the delay compensation with the PLL. The proposed DC-DC buck converter is fabricated with a $0.18{\mu}m$ BCD process, and the die area is $3.96mm^2$. It is implemented to have over a 90 % efficiency at an output voltage of 5 V when the input range is between 8 V and 20 V. As a result, the variation in the power efficiency is less than 1 % and the maximum efficiency of the proposed DC-DC buck converter with the PLL is 95.4 %.

Effect of the Control of Bowing in Free-standing GaN by Mechanical Polishing (Freestanding GaN 기판의 Ga-polar 면에 기계적 연마 방법을 적용한 Bow 제어 및 그 특성 연구)

  • Gim, Jinwon;Son, Hoki;Lim, Tae-Young;Lee, Mijai;Kim, Jin-Ho;Jeon, Dae-Woo;Hwang, Jonghee;Jung, Jung-Young;Oh, Hae-Kon;Kim, Jin-Hun;Choi, YoungJun;Lee, Hae-Yong;Yoon, Dae-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.12
    • /
    • pp.776-780
    • /
    • 2015
  • In this paper, we have studied the effect of mechanical polishing to Ga-polar face for reducing the wafer bowing and strain in free-standing GaN. After the mechanical polishing to Ga-polar face, the bowing of the free-standing GaN substrate significantly decreased with increasing the size of diamond slurry, and eventually changed the bowing direction from concave to convex. Furthermore, the full width at half maximum (FWHM) of high-resolution X-ray diffraction (HR-XRD) were decreased, especially the FWHM of (1 0 2) reflection for $1.0{\mu}m$ size of diamond slurry was significantly decreased from 630 to 203 arcsec. In the case, we confirmed that the compressive strain in Ga-polar face was fully released by Raman measurement.

Cyclic Responses of Steel Reinforced ECC Column under Reversed Cyclic Loading Conditions (철근 보강된 ECC 기둥의 반복하중에 대한 이력거동)

  • Hyun, Jung-Hwan;Shim, Young-Heung;Bang, Jin-Wook;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.4
    • /
    • pp.75-82
    • /
    • 2015
  • In this study, experimental research was carried out to evaluate steel reinforced ECC (Engineered Cementitious Composites) column, which exhibits excellent crack control property and highly ductile behavior. Ordinary portland cement and high volume fly ash were used as binding materials in the mixture proportions for the purpose of achieving a high level of multiple cracking property with the tightly controlled crack width. To compare with the cyclic behavior of steel reinforced ECC column specimen, a conventional reinforced concrete column was prepared and tested under reversed cyclic loading condition. Based on the cyclic load test, ECC column exhibited higher cyclic behavior, compared to the conventional RC column, in terms of load carrying capacity and energy dissipation capacity.

Utilization of Essential Oil Free Needles for Compost and Roughage (침엽정유추출잔사의 퇴비화 및 조사료 이용)

  • 최인규;강하영
    • Journal of Korea Foresty Energy
    • /
    • v.21 no.1
    • /
    • pp.7-15
    • /
    • 2002
  • The essential oil free needles, which were left after distillation of essential oil from various coniferous needles, were fermented with food waste organics in order to use as compost and roughage. Microorganisms for the fermentation were selected from domestic sources such as swine compost, bark compost, and kimchi, etc, and consisted of aerothermophilic bacteria and actinomycetes. The weight reduction ratio of food waste organics treated with the microorganisms was 90% after 30 days treatment, and the fermentation temperature was kept at approximately $45^{\circ}C$. The compost process was really slow due to chemical compounds derived from needles, and it finally took 60 days for complete compost. When 10% of needle compost was mixed with soil for radish growth, the growth indicators such as leaf length and root weight were increased compared with control, while root weight, root width, and root length were inhibited on the addition of 20% needle compost. The nutrient value and digestibility ratio of various essential oil free needles as roughage for ruminant animals were evaluated. The ratio of crude protein for essential oil free needles from Korean pine(Pinus koraiensis) was 10.02%, which was higher than those of rice straw(5.48%) and corn(9.00%). The digestibility ratios of essential oil free needles from Sawara cypress(Chamaecwaris pislfera), Korean pine(Pinus koraiensis), and Japanese Red Pine(Pinus densiflora) was 53%, 34%, 34%, respectively, indicating that those essential oil free needles were considered as excellent roughage.

  • PDF

A Capacitance Deviation-to-Time Interval Converter Based on Ramp-Integration and Its Application to a Digital Humidity Controller (램프-적분을 이용한 용량치-시간차 변환기 및 디지털 습도 조절기에의 응용)

  • Park, Ji-Mann;Chung, Won-Sup
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.12
    • /
    • pp.70-78
    • /
    • 2000
  • A novel capacitance deviation-to-time interval converter based on ramp-integration is presented. It consists of two current mirrors, two schmitt triggers, and control digital circuits by the upper and lower sides, symmetrically. Total circuit has been with discrete components. The results show that the proposed converter has a linearity error of less than 1% at the time interval(pulse width) over a capacitance deviation from 295 pF to 375 pF. A capacitance deviation of 40pF and time interval of 0.2 ms was measured for sensor capacitance of 335 pF. Therefore, the high-resolution can be known by counting the fast and stable clock pulses gated into a counter for time interval. The application of a novel capacitance deviation-to time interval converter to a digital humidity controller is also presented. The presented circuit is insensitive to the capacitance difference in disregard of voltage source or temperature deviation. Besides the accuracy, it features the small MOS device count integrable onto a small chip area. The circuit is thus particularly suitable for the on-chip interface.

  • PDF

Design and Fabrication of X-Band GaN HEMT SSPA for Marin Radar System (선박 레이더용 X-대역 300 W급 GaN HEMT 반도체 전력 증폭 장치 설계 및 제작)

  • Heo, John;Jin, Hyeong-Seok;Jang, Ho-Ki;Kim, Bo-Kyun;Cho, Sookhee
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.11
    • /
    • pp.1239-1247
    • /
    • 2012
  • In this paper, design and fabrication of solid state power amplifier(SSPA) using GaN HEMT chip for X-band frequency are presented. The SSPA consists of the power supply for stable power and the control unit for communication and controlling the internal module, the RF Part to amplify RF signal, In particular the adopted active device for the RF Parts is GaN HEMT Bare chip of TriQuint company, the RF parts consists of pre-stage, drive-stage, main power-stage and each amplifier is designed with input and out matching circuit. The developed power amplifier demonstrated more than 300 W peak output power in condition of 26 % duty, max. pulse width 100us for the X-band frequency( 500 MHz bandwidth) and can apply to marine radar systems.

Effect of neck design on peri-implant tissue responses in external connection type implant : a prospective pilot clinical study (외측연결형 임플란트 고정체의 경부 디자인이 임플란트 주위조직에 미치는 영향에 대한 전향적 예비 임상연구)

  • Bae, Eun-Bin;Lee, So-Hyoun;Jeon, Young-Chan;Kang, Eun-Sook;Park, Sang-Rye;Lee, Jin-Ju;Huh, Jung-Bo
    • The Journal of the Korean dental association
    • /
    • v.55 no.11
    • /
    • pp.766-776
    • /
    • 2017
  • This clinical study was conducted to evaluate the clinical effects of a concave neck of external connection type implant fixture designed for platform switching on the peri-implant tissue responses. Two types of implants with different neck designs were implanted in 20 patients. For the experimental group, the bioseal(BS) implant fixtures with 's' shaped concave profile on the neck were used, and non-bioseal(NBS) implant fixtures with a straight profile on the neck were used as control(Total of 40 implants, NBS: n = 19, BS: n=21). During the one-year period after implant placement, implant survival rate, marginal bone resorption, bleeding, plaque, and complications were evaluated. The survival rate of NBS and BS group was 94.74% and 90.48%, respectively. There was no significant difference on marginal bone resorption, bleeding and plaque between the two groups (P>.05). Within the limits of the present study, implants with a concave neck design showed similar clinical results to implants with a straight neck design on the peri-implant tissue responses. Longitudinal clinical studies are necessary to confirm more effective clinical results.

  • PDF