• Title/Summary/Keyword: width control

Search Result 2,405, Processing Time 0.025 seconds

Design of 5'' True Color FED Driving System (5'' True Color FED 구동시스템 설계)

  • Shin, Hong-Jae;Kwon, Oh-Kyong;Kwack, Kae-Dal
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.38 no.5
    • /
    • pp.70-78
    • /
    • 2001
  • We have developed a novel driving system of 5' true color FED using voltage controlled PWM method which has current control effect. The proposed method has the advantage of voltage controlled pulse width modulation method and current control method. Also, we propose a new circuit model of FED subpixel for circuit simulation of FED driving circuits, considering some parasitic effects, i.e., cross talk, line coupling effect and leakage current to the adjacent cathode lines. Output stage of the data driving circuit is optimized using the proposed circuit model. In video data processing, FED controller uses the parallel processing of R.G.B input data, so duty ratio is maximized and brightness of FED increases. With this results, no noise and high quality performance is achieved in display of 5' true color FED.

  • PDF

Dentoskeletal features in individuals with ectopic eruption of the permanent maxillary first molar

  • Mucedero, Manuela;Rozzi, Matteo;Cardoni, Giulia;Ricchiuti, Maria Rosaria;Cozza, Paola
    • The korean journal of orthodontics
    • /
    • v.45 no.4
    • /
    • pp.190-197
    • /
    • 2015
  • Objective: The aim of the study was to analyze the prevalence and distribution of ectopic eruption of the permanent maxillary first molar (EEM) in individuals scheduled for orthodontic treatment and to investigate the association of EEM with dental characteristics, maxillary skeletal features, crowding, and other dental anomalies. Methods: A total of 1,317 individuals were included and randomly divided into two groups. The first 265 subjects were included as controls, while the remaining 1,052 subjects included the sample from which the final experimental EEM group was derived. The mesiodistal (M-D) crown width of the deciduous maxillary second molar and permanent maxillary first molar, maxillary arch length (A-PML), maxillomandibular transverse skeletal relationships (anterior and posterior transverse interarch discrepancies, ATID and PTID), maxillary and mandibular tooth crowding, and the presence of dental anomalies were recorded for each subject, and the statistical significance of differences in these parameters between the EEM and control groups was determined using independent sample t -tests. Chi-square tests were used to compare the prevalence of other dental anomalies between the two groups. Results: The prevalence of maxillary EEM was 2.5%. The M-D crown widths, ATID and PTID, and tooth crowding were significantly greater, while A-PML was significantly smaller, in the EEM group than in the control group. Only two subjects showed an association between EEM and maxillary lateral incisor anomalies, which included agenesis in one and microdontia in the other. Conclusions: EEM may be a risk factor for maxillary arch constriction and severe tooth crowding.

Evaluation of the stability of maxillary expansion using cone-beam computed tomography after segmental Le Fort I osteotomy in adult patients with skeletal Class III malocclusion

  • Kim, Hoon;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.48 no.1
    • /
    • pp.63-70
    • /
    • 2018
  • Objective: The aim of this study is to quantitatively evaluate the stability of the skeletal and dental widths using cone-beam computed tomography (CBCT) after segmental Le Fort I osteotomy in adult patients with skeletal Class III malocclusion requiring maxillary expansion. Methods: In total, 25 and 36 patients with skeletal Class III malocclusion underwent Le Fort I osteotomy (control group) and segmental Le Fort I osteotomy (experimental group), respectively. Coronal CBCT images were used to measure the dental and skeletal widths before (T1) and after (T2) surgery and at the end of treatment (T3). The correlation between the extent of surgery and the amount of relapse in the experimental group was also determined. Results: In the control group, the dental width exhibited a significant decrease of $0.70{\pm}1.28mm$ between T3 and T2. In the experimental group, dental and skeletal expansion of $1.83{\pm}1.66$ and $2.55{\pm}1.94mm$, respectively, was observed between T2 and T1. The mean changes in the dental and skeletal widths between T3 and T2 were $-1.41{\pm}1.98$ and $-0.67{\pm}0.72mm$, respectively. There was a weak correlation between the amount of skeletal expansion during segmental Le Fort I osteotomy and the amount of postoperative skeletal relapse in the experimental group. Conclusions: Maxillary expansion via segmental Le Fort I osteotomy showed good stability, with a skeletal relapse rate of 26.3% over approximately 12 months. Our results suggest that a greater amount of expansion requires greater efforts for the prevention of relapse.

Control and Operating Characteristics of Three-Phase Matrix Converter with Unity Power Factor by Direct Duty-Ratio Modulation Method (단위 역률을 갖는 직접 시비율 변조방식 3상 매트릭스 컨버터의 제어 및 동작 특성)

  • Li, Yulong;Choi, Nam-Sup;Han, Byung-Moon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.142-149
    • /
    • 2009
  • This paper investigates operating characteristics of three-phase matrix converter with unity input power factor by direct duty-ratio pulse-width modulation in the case of balanced and unbalanced load. It can be found from the system analysis that (1) The control algorithm for unity power factor is not related to the variables of load sides but the input voltages, (2) With the balanced three-phase load except for the pure reactive load, the unity input power factor can be achieved, (3) In the case of the unbalanced linear load, the equivalent input characteristics of the matrix converter can be seen like the nonlinear resister, (4) When the input frequency and the output frequency have the specific relationship, each input phases have the same sharing of the average power. The feasibility and validity of the analysis were verified by simulation and experimental results.

Growth Response on the Euonymus fortunei 'Emelad' n 'Gold' as affected by Artificial Plantings Soil Properties during Dry Spring Season (봄철 건조기 용기형 벽면녹화에서 식재지반 조성에 따른 황금줄사철의 적응성)

  • Ju, Jin-Hee;Kim, Hea-Ran;Park, Heon;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.23 no.7
    • /
    • pp.1299-1305
    • /
    • 2014
  • For evaluating the effect of various artificial planting soil properties on the Euonymus fortunei 'Emelad'n Gold' growth, a container green wall system experiment was conducted in a wall of greenhouse at Konkuk University, Glocal campus. The experimental artificial planting grounds were prepared with different organic soil conditioner ratios (Control, $A_4O_1$, $A_2O_1$ and $A_1O_1$) and with drought tolerance and an ornamental value Euonymus fortunei 'Emelad'n Gold' was planted. The soil and plant characteristics were investigated from April to Jun 2010. The volumetric soil moisture contents were significantly increasing order as the amount of organic soil conditioner level increased in order to $A_1O_1$ > $A_2O_1$ > $A_4O_1$ > Control. At 4 treatment, soil chemical properties were inversely related to organic soil container ratios increase. The differences of root collar caliper, number of branch, and survival rate between the organic soil conditioner ratio were not significantly affected by organic soil conditioner. But, plant height, internode length, leaf length and leaf width were significantly shorter on plants planted $A_1O_1$ than plants planted other treatments. Therefore, Euonymus fortunei 'Emelad'n Gold' had good growth response regardless of organic soil conditioner ratio and the plant is expected to be a highly valuable shrub for the green wall system if it should be considered in integration with stormwater retention or as a soil conditioner for increasing soil water contents in artificial planting soil.

Benefits of mineralized bone cortical allograft for immediate implant placement in extraction sites: an in vivo study in dogs

  • Orti, Valerie;Bousquet, Philippe;Tramini, Paul;Gaitan, Cesar;Mertens, Brenda;Cuisinier, Frederic
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.5
    • /
    • pp.291-302
    • /
    • 2016
  • Purpose: The aim of the present study was to evaluate the effectiveness of using a mineralized bone cortical allograft (MBCA), with or without a resorbable collagenous membrane derived from bovine pericardium, on alveolar bone remodeling after immediate implant placement in a dog model. Methods: Six mongrel dogs were included. The test and control sites were randomly selected. Four biradicular premolars were extracted from the mandible. In control sites, implants without an allograft or membrane were placed immediately in the fresh extraction sockets. In the test sites, an MBCA was placed to fill the gap between the bone socket wall and implant, with or without a resorbable collagenous membrane. Specimens were collected after 1 and 3 months. The amount of residual particles and new bone quality were evaluated by histomorphometry. Results: Few residual graft particles were observed to be closely embedded in the new bone without any contact with the implant surface. The allograft combined with a resorbable collagen membrane limited the resorption of the buccal wall in height and width. The histological quality of the new bone was equivalent to that of the original bone. The MBCA improved the quality of new bone formation, with few residual particles observed at 3 months. Conclusions: The preliminary results of this animal study indicate a real benefit in obtaining new bone as well as in enhancing osseointegration due to the high resorbability of cortical allograft particles, in comparison to the results of xenografts or other biomaterials (mineralized or demineralized cancellous allografts) that have been presented in the literature. Furthermore, the use of an MBCA combined with a collagen membrane in extraction and immediate implant placement limited the extent of post-extraction resorption.

Hydroponic Culture System for Wasabi Leaf Production (고추냉이 잎 생산을 위한 수경재배)

  • Choi, Ki-Young;Lee, Yong-Beom;Lee, Joo-Hyun;Nasangargale, T.
    • Journal of Bio-Environment Control
    • /
    • v.16 no.1
    • /
    • pp.1-6
    • /
    • 2007
  • This experiment was conducted to possibility for leaf production of wasabi using hydroponics system. When they were grown in aeroponics and soiless culture such as saprolite and Coir, photosynthesis and transpiration rate were high and marketable yield $(leaf\;width\;11{\sim}13cm)$ showed $11.2{\sim}11.7$ of leaf number per plant and $52{\sim}53.8g$ fresh weight. In spring periods, the highest yield was 25.7 of leaf number per plant in nutrient solution of Yamasaki's solution developed in Japan in deep culture during 130 days. It showed be possibility that marketable leaves harvested one leaf every $2{\sim}4$ days though spring and fall culture periods using hydroponics controlled in environmental culture.

The turbulent wake of a square prism with wavy faces

  • Lin, Y.F.;Bai, H.L.;Alam, Md. Mahbub
    • Wind and Structures
    • /
    • v.23 no.2
    • /
    • pp.127-142
    • /
    • 2016
  • Aerodynamic effects, such as drag force and flow-induced vibration (FIV), on civil engineering structures can be minimized by optimally modifying the structure shape. This work investigates the turbulent wake of a square prism with its faces modified into a sinusoidal wave along the spanwise direction using three-dimensional large eddy simulation (LES) and particle image velocimetry (PIV) techniques at Reynolds number $Re_{Dm}$ = 16,500-22,000, based on the nominal width ($D_m$) of the prism and free-stream velocity ($U_{\infty}$). Two arrangements are considered: (i) the top and bottom faces of the prism are shaped into the sinusoidal waves (termed as WSP-A), and (ii) the front and rear faces are modified into the sinusoidal waves (WSP-B). The sinusoidal waves have a wavelength of $6D_m$ and an amplitude of $0.15D_m$. It has been found that the wavy faces lead to more three-dimensional free shear layers in the near wake than the flat faces (smooth square prism). As a result, the roll-up of shear layers is postponed. Furthermore, the near-wake vortical structures exhibit dominant periodic variations along the spanwise direction; the minimum (i.e., saddle) and maximum (i.e., node) cross-sections of the modified prisms have narrow and wide wakes, respectively. The wake recirculation bubble of the modified prism is wider and longer, compared with its smooth counterpart, thus resulting in a significant drag reduction and fluctuating lift suppression (up to 8.7% and 78.2%, respectively, for the case of WSP-A). Multiple dominant frequencies of vortex shedding, which are distinct from that of the smooth prism, are detected in the near wake of the wavy prisms. The present study may shed light on the understanding of the underlying physical mechanisms of FIV control, in terms of passive modification of the bluff-body shape.

Evaluation of electrical characterization and critical length of interconnect for high-speed MCM (고속 MCM 배선의 전기적 특성 및 임계길이 평가)

  • 이영민;박성수;주철원;이상복;백종태;김보우
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.10
    • /
    • pp.67-75
    • /
    • 1998
  • This paper examined the geometrical variables of microstrip to control the characteristic impedance of MCM interconnect and also with respect to the practical requirements, evaluated the critical lengths for attenuation, propagation delay, and crosstalk at 500 MHz frequency compared to at 50 MHz frequency. With the illustration of each MCM-L and MCM-D interconnect having 50 characteristic impedance, it was revealed that the most important geometrical variables to control the characteristic impedance of microstrip are eventually dielectric thickness and line width. In particular, the dielectric thickness of MCM-D interconnect must be controlled with tolerance below 2 m. It is clear that the attenuation does not give rise to signal distortion in the range of up to 500MHz frequency for both MCM-L and MCM-D interconnects. However, the propagation delay is so significant that both MCM-L and MCM-D interconnects should be matched with load at the 500 MHz frequency. For the MCM-D interconnect, the crosstalk voltage would not be high to generate the wrong signal on the neighboring line at 500 MHz frequency, but the MCM-L interconnect could not be used due to severe crosstalk. Eventually, it is clear that the transmission line behavior must be studied for the design of MCM substrate at the 500 MHz frequency.

  • PDF

A New Standard Gerbera Cultivar 'Harmony' with Pink and Semi-double Adaptable to High Temperature (대륜계통의 고온적응성 분홍색 반겹꽃 거베라 신품종 'Harmony')

  • Park, Sang Kun;Lim, Jin Hee;Choi, Seong Youl;Shin, Hak Ki;Huh, Yeun Joo
    • Horticultural Science & Technology
    • /
    • v.31 no.2
    • /
    • pp.255-258
    • /
    • 2013
  • A new gerbera cultivar 'Harmony' was bred by the National Institute of Horticultural & Herbal Science in 2010. 'Pavilov' with pink and 'Marathon' with purple, which have semi-double flower, were crossed in 2007. After investigation of the characteristics for four years (from 2007 to 2010), it was selected specially for the use as a cut flower. The 'Harmony' had brilliant pink color (RHS R49B) with dark brown center. The flower was semi-doubled with 11.8 cm in diameter. It had a long and thick peduncle with length and upper width 59.2 cm and 3.9 mm, respectively. The vase life of 'Harmony' was 12.0 days, which was 3 days longer than the control cultivar. And its average yield was 57.0 stems per plant, which were 10.5 stems more than the control.