• Title/Summary/Keyword: wide temperature range

Search Result 1,006, Processing Time 0.027 seconds

A Full Inorganic Electroluminescent Microdisplay

  • Smirnov, A.;Labunov, V.;Lazarouk, S.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.1075-1080
    • /
    • 2003
  • Design and fabrication process of a full inorganic electroluminescent microdislay based on aluminum / nanostructured porous silicon reverse biased light emitting Schottky diodes are discussing. Being of a solid state construction. this micro-display is cost-effective, thin and light in weight due to very simple device architecture. Its benefits include also super high resolution, wide viewing angles, fast response time and wide operating temperature range. The advantages of full integration of a LED-array and driving circuitry onto a Si-chip will be also discussed.

  • PDF

The Dependence of Temperature and Frequency for the Dissipation Factor in Liquid Dielectrics (액체절연체(실리콘유) 유전정접의 온도및 주파수의존성)

  • 이돈희;소병문;이수원;김왕곤;홍진웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1993.11a
    • /
    • pp.85-89
    • /
    • 1993
  • Silicone oil exhibits the properies of both organic and inorganic substances and, thus, it has many superior properties such as higher thermal resistance and lower thermal oxidation level when compared to other dielectric liquids. In order to investigate the dielectric characteristics, dielectric liquids of viscosity 1 [cSt] is chosen as the specimen and experiment is performed in the temperature range of 20∼65 [$^{\circ}C$] and frequency range of 30∼1${\times}$10$\^$6/ [Hz] respectively. As a result, the observed linear decrease in dissipation factor at the frequency range below 3 [kHz] is due to the influence of frequency, whereas the increase in dissipation factor at higher frequency range is contributed by electrode's resistance. At a fixed frequency of 30 [kHz], increasing temperature results in higher peak value and wide width of the absorption curve. This is due to the increase in dipole and viscosity. As temperature increases, dipole moment is decreased from 0.98 to 0.64 [debye]. The activation energy which causes the relaxation and loss of dielectric is obtained about 15 [kcal/mole].

  • PDF

Read-Out Integrated Circuit of Colorimetry-Based Optical Sensor for Eutrophication Analysis (수생태계 부영양화 분석을 위한 비색법 기반의 광학식 센서 신호처리회로(ROIC)구현)

  • Koo, Seong Mo;Jung, Dong Geon;Choi, Young Chan;Kim, Kyung-Kyoo;Kong, Seong Ho
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.270-274
    • /
    • 2020
  • In this study, a read-out integrated circuit (ROIC) that can be applied to a colorimetry-based optical sensor for analyzing total phosphorus and total nitrogen was developed and characterized. The proposed ROIC minimizes the effect on temperature fluctuation, improves sensitivity, and extends the dynamic range by utilizing a dual optical path and feedback control circuit. Using a dual optical path makes it possible to calibrate the output signal of the optical sensor automatically, along with the temperature fluctuation. The calibrated voltage is fed back into the measurement stage; thus, the output current of the measurement is adaptively controlled. As a result, the sensitivity and dynamic range of the proposed ROIC are improved. Finally, a total-phosphorus analysis was conducted by utilizing the ROIC. The ROIC was found to operate stably over a wide temperature range.

A Study of Hydrodenitrogenation of Quinoline Catalyzed by Sulfided $Ni-Mo/\gamma - Al_2O_3$ (황화 $Ni-Mo/\gamma - Al_2O_3$ 촉매상에서 Quinoline의 수소첨가탈질반응에 관한 연구)

  • 최응수;이원묵;김경림
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.1
    • /
    • pp.52-61
    • /
    • 1989
  • The hydrodenitrogenation of quinoline dissolved in n-heptane was studied over sulfided Ni-Mo/$\gamma-Al_2O_3$ catalyst at the range of the temperature between 553 K and 673 and the total pressure between $20 \times 10^5$ Pa and $60 \times 10^5$ Pa in a fixed bed flow reactor. Quinoline conversion was very high at relatively low temperature and total pressure, and decreased with quinoline partial pressure. The thermodynamic equilibrium between quinoline and Py-THQ existed in wide ranges of experimental conditions and shifted in favor of quinoline at higher temperature. At the range of the temperature betwwen 553 K and 673 K and at the total pressure $60 \times 10^5$ Pa, the quinoline reaction rate was 1st order with respect to the concentr4ation of quinoline and its apparent activation energy was 7.15 Kcal/mole.

  • PDF

Deformation Characteristic by Compression in High-Nitrogen Austenitic Stainless Steel (고질소강 오스테나이트계 스테인레스강의 압축변형특성)

  • Lee, J.W.;Kim, D.S.;Kim, B.K.;Lee, M.R.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.10a
    • /
    • pp.139-141
    • /
    • 2007
  • Compression tests were carried out to investigate morphologies of compressed specimen, deformation microstructure and stress-strain relation in high-nitrogen austenite stainless steel. Tests were performed under a wide range of temperature and, with true strain rates up to $\dot{\varepsilon}$ =0.05, 0.1, 0.5 and $1.0s^{-1}$. The activation energy of loading force was equal to plastic deformation energy within the temperature range of $900^{\circ}C$ to $1250^{\circ}C$. Dynamically recrystallized grain size decreased with an increasing strain rate and temperature. Flow stresses and deformation microstructures, were used to quantify the critical strain rate and recrystallized grain size. The grain size versus strain rate-temperature map obtained in the study was in good agreement with the deformation microstructures of compressed specimens.

  • PDF

Depositon of Transparent Conductive Films by a DC arc Plasmatron

  • Penkov, O.V.;Plaksin, V. Yu.;Joa, S.B.;Kim, J.H.;LEE, H.J.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.480-480
    • /
    • 2010
  • In the present work, we studied effect of the deposition parameters on the structure and properties of ZnO films deposited by DC arc plasmatron. The varied parameters were gas flow rates, precursor composition, substrate temperature and post-deposition annealing temperature. Vapor of Zinc acetylacetone was used as source materials, oxygen was used as working gas and argon was used as the cathode protective gas and a transport gas for the vapor. The plasmatron power was varied in the range of 700-1,500 watts. Flow rate of the gases and substrate temperature rate were varied in the wide range to optimize the properties of the deposited coatings. After deposition films were annealed in the hydrogen atmosphere in the wide range of temperatures. Structure of coatings was investigated using XRD and SEM. Chemical composition was analyzed using x-ray photo-electron spectroscopy. Sheet conductivity was measured by 4-point probe method. Optical properties of the transparent ZnO-based coatings were studied by the spectroscopy. It was shown that deposition by a DC Arc plasmatron can be used for low-cost production of zinc oxide films with good optical and electrical properties. Sheet resistance of 4 Ohms cm was achieved after the deposition and 30 min annealing in the hydrogen at $350^{\circ}C$. Elevation of the substrate temperature during the deposition process up to $350^{\circ}C$ leads to decreasing of the film's resistance due to rearrangement of the crystalline structure.

  • PDF

Effect of C/Ti Atom Ratio on the Deformation Behavior of TiCχ Grown by FZ Method at High Temperature

  • Shin, Soon-Gi
    • Korean Journal of Materials Research
    • /
    • v.23 no.7
    • /
    • pp.373-378
    • /
    • 2013
  • In order to clarify the effect of C/Ti atom ratios(${\chi}$) on the deformation behavior of $TiC_{\chi}$ at high temperature, single crystals having a wide range of ${\chi}$, from 0.56 to 0.96, were deformed by compression test in a temperature range of 1183~2273 K and in a strain rate range of $1.9{\times}10^{-4}{\sim}5.9{\times}10^{-3}s^{-1}$. Before testing, $TiC_{\chi}$ single crystals were grown by the FZ method in a He atmosphere of 0.3MPa. The concentrations of combined carbon were determined by chemical analysis and the lattice parameters by the X-ray powder diffraction technique. It was found that the high temperature deformation behavior observed is the ${\chi}$-less dependent type, including the work softening phenomenon, the critical resolved shear stress, the transition temperature where the deformation mechanism changes, the stress exponent of strain rate and activation energy for deformation. The shape of stress-strain curves of $TiC_{0.96}$, $TiC_{0.85}$ and $TiC_{0.56}$ is seen to be less dependent on ${\chi}$, the work hardening rate after the softening is slightly higher in $TiC_{0.96}$ than in $TiC_{0.85}$ and $TiC_{0.56}$. As ${\chi}$ decreases the work softening becomes less evident and the transition temperature where the work softening disappears, shifts to a lower temperature. The ${\tau}_c$ decreases monotonously with decreasing ${\chi}$ in a range of ${\chi}$ from 0.86 to 0.96. The transition temperature where the deformation mechanism changes shifts to a lower temperature as ${\chi}$ decreases. The activation energy for deformation in the low temperature region also decreased monotonously as ${\chi}$ decreased. The deformation in this temperature region is thought to be governed by the Peierls mechanism.

Performance test and uncertainty analysis of the FBG-based pressure transmitter for liquid metal system

  • Byeong-Yeon KIM;Jewhan LEE;Youngil CHO;Jaehyuk EOH;Hyungmo KIM
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4412-4421
    • /
    • 2022
  • The pressure measurement in the high-temperature liquid metal system, such as Sodium-cooled Fast Reactor(SFR), is important and yet it is very challenging due to its nature. The measuring pressure is relatively at low range and the applied temperature varies in wide range. Moreover, the pressure transfer material in impulse line needs to considered the high temperature condition. The conventional diaphragm-based approach cannot be used for it is impossible to remove the effect of thermal expansion. In this paper, the Fiber Bragg Grating(FBG) sensor-based pressure measuring concept is suggested that it is free of problems induced by the thermal expansion. To verify this concept, a prototype was fabricated and tested in an appropriate conditions. The uncertainty analysis result of the experiment is also included. The final result of this study clearly showed that the FBG-based pressure transmitter system is applicable to the extreme environment, such as SFR and any other high-temperature liquid metal system and the measurement uncertainty is within reasonable range.

Characteristics of an 1.25 Gbps 850 nm Oxide VCSEL Transmitter Operating at Fixed Current over a Wide Temperature Range (넓은 온도 범위에서 고정 구동전류로 동작하는 1.25 Gbps 850 nm 산화형 VCSEL 송신기의 특성)

  • Kim, Tae-Ki;Kim, Tae-Yong;Kim, Sang-Bae;Kim, Sung-Han
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.12
    • /
    • pp.43-53
    • /
    • 2007
  • We have analyzed low current operation characteristics of a VCSEL transmitter operating at fixed Current over wide temperature range. Used 850 nm oxide VCSEL has low temperature dependence of the threshold current and $d^2I_{th}/dT^2$ is approximately $1.346\times10^{-4}mA/^{\circ}C^2$. We fixed on-current so that output power from the chip is 1 mW at $20^{\circ}C$ and investigated the turn-on, turn-off characteristics and eye-diagram of the 850 nm oxide VCSEL transmitter with varying ambient temperature and off-current. We measured rise time, fall time, extinction ratio and timing jitter by changing tile ambient temperature and off-current. With the fixed off-current of around $0.1\sim0.2mA$ lower than the lowest threshold current the transmitter successfully operated at 1.25 Gbps over a wide temperature range from $-20^{\circ}C$ to $80^{\circ}C$.

Evaluation of the Wet Bulb Globe Temperature (WBGT) Index for Digital Fashion Application in Outdoor Environments

  • Kwon, JuYoun;Parsons, Ken
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.1
    • /
    • pp.23-36
    • /
    • 2017
  • Objective: This paper presents a study to evaluate the WBGT index for assessing the effects of a wide range of outdoor weather conditions on human responses. Background: The Wet Bulb Globe Temperature (WBGT) index was firstly developed for the assessment of hot outdoor conditions. It is a recognised index that is used world-wide. It may be useful over a range of outdoor conditions and not just for hot climates. Method: Four group experiments, involving people performing a light stepping activity, were conducted to determine human responses to outside conditions in the U.K. They were conducted in September 2007 (autumn), December 2007 (winter), March 2008 (spring) and June 2008 (summer). Environmental measurements included WBGT, air temperature, radiant temperature (including solar load), humidity and wind speed all measured at 1.2m above the ground, as well as weather data measured by a standard weather station at 3m to 4m above the ground. Participants' physiological and subjective responses were measured. When the overall results of the four seasons are considered, WBGT provided a strong prediction of physiological responses as well as subjective responses if aural temperature, heart rate and sweat production were measured. Results: WBGT is appropriate to predict thermal strain on a large group of ordinary people in moderate conditions. Consideration should be given to include the WBGT index in warning systems for a wide range of weather conditions. However, the WBGT overestimated physiological responses of subjects. In addition, tenfold Borg's RPE was significantly different with heart rate measured for the four conditions except autumn (p<0.05). Physiological and subjective responses over 60 minutes consistently showed a similar tendency in the relationships with the $WBGT_{head}$ and $WBGT_{abdomen}$. Conclusion: It was found that either $WBGT_{head}$ or $WBGT_{abdomen}$ could be measured if a measurement should be conducted at only one height. The relationship between the WBGT values and weather station data was also investigated. There was a significant relationship between WBGT values at the position of a person and weather station data. For UK daytime weather conditions ranging from an average air temperature of $6^{\circ}C$ to $21^{\circ}C$ with mean radiant temperatures of up to $57^{\circ}C$, the WBGT index could be used as a simple thermal index to indicate the effects of weather on people. Application: The result of evaluation of WBGT might help to develop the smart clothing for workers in industrial sites and improve the work environment in terms of considering workers' wellness.