• 제목/요약/키워드: wet bulb temperature

검색결과 87건 처리시간 0.02초

第二減速 乾燥期에 있어서의 假濕球溫度의 普偏性 (The Universality of the Pseudo Wet Bulb Temperature During the Second Falling Rate Period)

  • 박성신
    • 대한화학회지
    • /
    • 제16권2호
    • /
    • pp.106-116
    • /
    • 1972
  • 물 및 Methyl Alcohol 과 같은 液體에 젖은 巨大孔 不活性 微少孔 不活性 및 微小孔 濕潤性 物質을 乾燥할때 假濕球 溫度가 普扁的으로 形成되며 假濕球 溫度는 空氣乾操의 第 2 減速期中 乾球溫度와 濕球溫道間에 나타난 하나의 새로운 一定溫道이다. 이 溫度는 液體 空氣 境界에서의 熱傳達, 蒸氣壙散, 液體蒸發 現象을 考慮한 式으로 計算되며 Nissan Bolles 및 George가 誘導한 式에 依하여 計算된 數値는 實險結果値와 一致한다.

  • PDF

유동층습도계와 아스만습도계의 비교 연구 (Comparative Study of Fluidized Bed-type and Assmann Psychrometer)

  • 강희찬;강민철
    • 설비공학논문집
    • /
    • 제15권9호
    • /
    • pp.779-785
    • /
    • 2003
  • The present work proposed a newly developed fluidized bed-type psychrometer that could be applicable to the high temperature and contaminant gases. The psychrometer is a device that test gas passes through the water in a glass bottle as a bubbly flow to obtain the adiabatic saturation temperature. A fluidized bed-type psychrometer was made and its characteristics were compared with the Assmann Psychrometer. The characteristic time was in the order of a hundred seconds, and decreased for the decrease of the mass of water and the increase of the air flow rate. The air flow rate and the insulation of the glass bottle were definitely important in the accurate measurement of the wet bulb temperature. The error in wet bulb temperature became less than 5 percent of the difference of dry and wet bulb temperatures if the air velocity in the glass bottle was greater than 1.5m/s.

황색종 연초 황변기 cyclic건조가 건조엽의 물리성에 미치는 영향 (Effect of Cyclic Change of Wet Bulb Temperature During Yellowing Stage on Physical Properties of Flue-Cured Tobacco)

  • 이철환;진정의;한철수
    • 한국연초학회지
    • /
    • 제20권1호
    • /
    • pp.13-18
    • /
    • 1998
  • In the flue curing process, the wet bulb temperature is usually controlled at a constant level. To improve the quality of flue cured leaves, we studied the effect of the cyclic change of wet bulb temperature at the yellowing stage of flue curing on physical properties of cured leaves. The wet bulb temperature was automatically controlled between preset high (38℃) and low point (35℃) every one hour cyclically. As a result, the acceleration of the increase in the physical properties of cured leaves were observed. The leaves cured by this method were more or less orange in color, better bodied, and less brittle compared with the leaves produced by conventional curing. However, the leaves cured by this method had a little sharpness and harshness. As to the physical properties, there was decreased in occurrence of flat leaves than that of conventional ones. On the other hand, in case of cyclic curing method, increase of price per kg reached to 2-3% compared with those of conventional ones.

  • PDF

황색종 cyclic 건조엽의 화학성분 특성 (Effect of cyclic Change of Wet Bulb Temperature During Yellowing Stage on Chemical Properties of Flue-Cured Tobacco)

  • 이철환;진정의;한철수
    • 한국연초학회지
    • /
    • 제20권1호
    • /
    • pp.19-25
    • /
    • 1998
  • The bulk curing experiment to the improve the quality of flue-cured leaves were carried out to evaluate relationship between cyclic curing and conventional curing method. We studied the effect of the cyclic change of wet bulb temperature at the yellowing stage of flue curing on chemical properties of cured leaves. The wet bulb temperature was automatically controlled between preset high($38^{\circ}C$) and low point ($35^{\circ}C$) everyone hour cyclically during 12 hours after starting luring. As a result, the acceleration of the increase in the chemical properties of cured leaves were observed. As to the chemical properties, there was decreased in citric acid, increased in malic acid of the nonvolatile organic acids and all higher fatty acids content of leaves cured by this method compared with in that of conventional curing method, while a major chemical compounds in relation to aromatic essence of cigarette smoke in essential oil components of lured leaves was mostly higher in this method than those of conventional ones, and it was evaluated that there was decreased in CO, TPM, Tar, and $CO_2$ content of the cigarette smoke comparing to the conventional luring method.

  • PDF

폐열회수 환기유닛의 인증시험 방법에 대한 오차분석 (Uncertainty Analysis of Test Method for Heat Recovery Ventilators)

  • 한화택;추연복
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.423-428
    • /
    • 2006
  • Twenty nine HRV models have been tested for last two years since the attestation system has been started by KARSE. It is the objective of the present study to analyze the performance test results. Uncertainty analysis has been conducted to find the effects of measured variables on the uncertainties of test results. The uncertainty of enthalpy is found to be affected by the uncertainty of wet bulb temperature significantly, but not by that of dry bulb temperature for the present range of parameters. The uncertainty of effective enthalpy efficiency is calculated to be 6%P for the cooling condition, and 3%P for the heating condition approximately. In order to reduce the uncertainty of the test results, the uncertainty of wet bulb temperature should be minimized and the indoor/outdoor test conditions should be modified so as to increase the enthalpy difference.

  • PDF

간역열부하계산용(簡易熱負荷計算用) Bin기상(氣象)데이터 (Development of Bin Weather Data for Simplified Energy Calculations)

  • 김두천;최진희
    • 대한설비공학회지:설비저널
    • /
    • 제17권1호
    • /
    • pp.28-43
    • /
    • 1988
  • The purpose of this research is to produce bin weather data for Seoul from Standard Weather Data. The intended use of these data is for input to recently developed models for simplified energy calculations and for generating variable-base degree-day information. The data produced under this study include $3^{\circ}C$ bin data covering the full range of dry-bulb temperatures with mean coincident wet-bulb and daytime coincident solar radiation, wet-bulb bins down to freezing temperature, wind speed bins with prevailing directions, and heating and cooling degree hours to nine different temperature bases. All of these data are tabulated in six separate time periods and total daily categories for monthly and annual periods.

  • PDF

노즐 팽창장치를 적용한 냉동시스템의 성능에 관한 실험적 연구 (An Experimental study on the Performance of a Refrigeration System using Nozzles as Expansion Devices)

  • 박윤철;고광수
    • 한국지열·수열에너지학회논문집
    • /
    • 제20권1호
    • /
    • pp.1-7
    • /
    • 2024
  • To In this study, a nozzle which is designed to work as expansion device was installed in a refrigeration system and performance test was conducted. The nozzle has 0.8mm, 1.0mm, 1.2mm diameter and inserted in a body of the devices. System performance was compared with a electronic expansion device(EEV, electric expansion valve) and designed nozzles at the environmental conditions such as dry bulb and wet bulb temperature. To reduce energy loss in the evaporator, a nozzle was inserted into the evaporator. In the comparison test, the opening of the EEV was adjusted to the same diameter as the 3 nozzles, and the experiments conducted at a 27℃ dry bulb temperature and 19.5℃ wet bulb temperature with 50% relative humidity as defined at KS C 9306 standard. To find out the effect of the environmental condition, the bulb temperature was varied 5 degree lower and higher than the standard condition temperature with the same relative humidity condition at 50%. The air flow rate to the evaporator was also changed 4, 7 and 10 m3/min. As results, the temperature drop in the nozzle was 153% higher than that of the EEV and the enhancement of the performance(COP) was up to 125.7% if install the nozzles in the refrigeration system. The highest performance was obatained at 1.0mm diameter nozzle.

NTU법을 이용한 대향류형 냉각탑의 성능해석에 관한 연구 (A study on the counter-flow cooling tower performance analysis using NTU-method)

  • 김영수;서무교;이상경
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.598-604
    • /
    • 1999
  • The thermal performance of cooling towers is affected by the temperature of inlet water, wet bulb temperature of entering air add water-air flow rate. In this study, the effects of these variables are simulated using NTU-method and experimentally investigated for the counter-flow cooling towers. The simulation program to evaluate these variables which affect the performance of cooling tower was developed. The maximum errors between the results of simulations and experiments were 3.8% under the standard design conditions and 5.4% under the other conditions. The performance was increased up to 46~50% as the water loading was increased from $6.8m^3$/$hr\cdot m^2$ to $15.9m^3$/$hr\cdot m^2$. The range was reduced up to 56~42% when the wet bulb temperature of the entering air was increased from $22^{\circ}C\; to\; 29^{\circ}C.$

  • PDF

쇼케이스의 적상 및 제상 특성 (Frosting and defrosting characteristics of a showcase system)

  • 노현일;박윤철;김용찬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.309-313
    • /
    • 2000
  • An experimental study was conducted to analyze the characteristics of the showcase refrigeration system during frosting and defrosting process. Test showcase was constructed with a cooling capacity of 3RT including 3 evaporators. The dynamic characteristics of the system under frosting and defrosting conditions were investigated. Refrigerant temperature and pressure of the system, dry bulb and wet bulb temperature of air passing through the evaporator, air flow rate and compressor power were measured.

  • PDF

도심 녹음수의 체감온도지수(WBGT) 조절효과 (The Effect of Urban Shade Trees on the WBGT(Wet Bulb Globe Thermometer Index))

  • 주민진;이춘석;류남형
    • 한국조경학회지
    • /
    • 제32권3호
    • /
    • pp.51-59
    • /
    • 2004
  • Focusing on WBGT(Wet Bulb Globe Thermometer Index) according to the LAI(Leaf Area Index) variation of trees, this study verifies the effects of urban shade trees on the outdoor thermal environment. As for methodology, air$.$globe temperature, air humidity and WBGT were measured under three shade trees whose LAIs were 2.1, 4.0 and 8.2 respectively at midday(12:00-13:00) of 14 sunny days from the 4th through the 29th day of September 2003. Those factors were also measured at the unshaded areas and compared with the values of shaded areas. The measured site was paved with interlocking concrete bricks. The measurements were analyzed through the ANCOV A(Analysis of Covariance) and the regression routines of SPSS11 for windows (SPSS Inc., 2001). The major findings were as follows. 1. The direct correlation between WBGT and LAI was very low. On the contrary, the WBGT showed close correlation with air$.$globe temperature and air humidity, and the LAI also showed very close correlation with globe temperature. These results tell that dominant shading effect by the tree is on the screening of direct solar radiation which lower the globe temperature and WBGT consequently. 2. While the average globe temperatures and WBGT at unshadowed area were 40.4$^{\circ}C$ and 26.2$^{\circ}C$ respectively, the former under the shade tree with LAI 2.1, 4.0 and 8.2 were 34.5$^{\circ}C$, 32.6$^{\circ}C$ and 30.2$^{\circ}C$, and the latter were 24.6$^{\circ}C$, 24$^{\circ}C$ and 23.4$^{\circ}C$ respectively. 3. The relationship between LAI(x) and WBGT(y) can be presented with the following equation: y = 24.23+1.53 $e^{-x}$+0.36x $e^{-x}$+0.46 $x^2$ $e^{-x}$ ($R^2$ =.98) =.98)