• Title/Summary/Keyword: weight center movement

Search Result 123, Processing Time 0.023 seconds

Effects of floor type and hanging type environmental enrichment on the behavior of growing pigs (바닥형과 현수형 환경 보조물이 육성돈의 행동에 미치는 영향)

  • Kim, Doo-Wan;Kim, Young-Hwa;Min, Ye-Jin;Yu, Dong-Jo;Jeong, Yong-Dae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.282-289
    • /
    • 2017
  • Animal Welfare is spreading throughout the world, but remains weak in Korean swine farms. Therefore, the aim of this study was to identify the effect of floor type and hanging type environmental enrichment on the behavior of growing pigs under the traditional feeding environment. A total of 45 crossbred pigs (Yorkshire${\times}$Landrace${\times}$Duroc; average weight, $33.35{\pm}5.5kg$) were assigned into three treatments consisting of control, hanging type(T1) and floor type(T2) with three replicates in semi-slurry pen. The hanging enrichment was suspended at shoulder height of the pigs, and the floor enrichment was fixed in the center of the pens. Growth and cortisol were estimated at the end of the experimental period. Behaviour patterns were analyzed on the first and eighth days after starting the experiment. Growth was not differed among control and treatments. However, cortisol was decreased in T2 compared to control(25.28 vs. 46.75 ng/mL; p<0.05). On the first day, movement and aggression were lower in both treatments than in control(p<0.01). On the eighth day, time and frequency of playing action were increased in T2 compared to T1(p<0.01) and both treatment groups showed more active behaviour than control(p<0.01). These results suggested that the enrichment may meet the natural action requirement of pigs. Therefore, our data can be utilized as basic information for welfare with environmental enrichments in farm animals.

An Effect of Aquatic Exercise Program with Self-help Group Activites and Strategies for Promoting Self-efficacy on Pain, Physiological Parameters and Quality of Life in Patients having Rheumatoid Arthritis. (자조집단 활동과 자기효능성 증진법을 이용한 수중운동 프로그램이 류마티스 관절염 환자의 통증, 생리적 지수 및 삶의 질에 미치는 영향)

  • Kim, Jong-Im
    • Journal of muscle and joint health
    • /
    • v.1 no.1
    • /
    • pp.1-30
    • /
    • 1994
  • Rheumatoid arthritis is a chronic systematic disease with unpredictable course of exacerbation and remission, characterized by pain, joint deformity and reduced activity by joint limitation. The growing public awareness of the need for health management of chronic illnesses, provides impetus for nursing to demonstrate social effectiveness by active nursing intervention in this vast area in general, and with rheumatoid condition in particular. However, nursing interventions to date have not demonstrated its active participation in the management of chronic conditions. Nursing intervention for the patients having rheumatoid arthritis is one such area that needs to be studied intensively and to demonstrate their effectiveness empirically. The purposes of this study were two fold : first, to develop a comprehensive program that was intensified with therapeutic joint exercises in water, self-help group activities and utilization of self-efficacy promoting strategies : and secondly, to determine the effect of aquatic exercise program on pain, physiological changes and quality of life in the rheumatoid arthritis patients. Thirty five female subjects participating in this study were selected from outpatients in the Rheumatism Center, Hanyang University hospital. The period of data collection was from December, 1992 to March, 1993 in seoul and Taejeon. Subjects in Taejeon were assigned to the experimental group. The comprehensive aquatic exercise program for the experimental group was carried out three times a week for 6 weeks in regular swimming pool. Subjects in Seoul did not participated in the program, and treated as the control group. Data were analyzed with repeated measure MANCOVA, t-test, ANCOVA, percentage of change, Kruskal-Wallis 1-Way ANOVA using SPSS $PC^+$ program. Results were obtained as follows : 1) Scores on Korean pain scale, Numeric pain score, and RAI score of the experimental group were significantly lower than those of the control group (t=2.11, p=0.022 ; F=4.40, p=0.044 : t=3.10, p=0.002). 2) There was significant improvement in the physiological parameters (higher joint movement parameters, F=15.64, p=0.024 ; higher lean body mass, percentage of change=+12.2, lower body weight, t=1.01, p=0.026 : lower ESR, t=1.69, p=0.001) in the experimental group compaired with subjects In the control group. 3) There was significant improvement in the specific self-efficacy score through the comprehensive aquatic exercise program(t=2.73, p=0.011), but not in the general self- efficacy score(t=0.62, p=0.113). 4) The quality of life failed to show significant improvement in the experimental group as compaired with the control group (F=3.69, p=0.064). 5) In the experimental group, findings from additional analysis showed no significant difference in the specific self-efficacy between those who continued to aquatic exercise after completing 6 week program and those who stopped (X2=0.086, p=0.690). Therefore, adherence to aquatic exercise program for 6 weeks seem to be affected mainly by self-help group activities. An indepth study to delve into articulation of mechanisms affecting the effect of aquatic exercise program be recommended. A further study is necessary to determine the difference in the effect of group and individual aquatic exercise program, to assess factors affecting adherence to exercise for an extended length of time.

  • PDF

Evaluation of the Usefulness of Exactrac in Image-guided Radiation Therapy for Head and Neck Cancer (두경부암의 영상유도방사선치료에서 ExacTrac의 유용성 평가)

  • Baek, Min Gyu;Kim, Min Woo;Ha, Se Min;Chae, Jong Pyo;Jo, Guang Sub;Lee, Sang Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.7-15
    • /
    • 2020
  • Purpose: In modern radiotherapy technology, several methods of image guided radiation therapy (IGRT) are used to deliver accurate doses to tumor target locations and normal organs, including CBCT (Cone Beam Computed Tomography) and other devices, ExacTrac System, other than CBCT equipped with linear accelerators. In previous studies comparing the two systems, positional errors were analysed rearwards using Offline-view or evaluated only with a Yaw rotation with the X, Y, and Z axes. In this study, when using CBCT and ExacTrac to perform 6 Degree of the Freedom(DoF) Online IGRT in a treatment center with two equipment, the difference between the set-up calibration values seen in each system, the time taken for patient set-up, and the radiation usefulness of the imaging device is evaluated. Materials and Methods: In order to evaluate the difference between mobile calibrations and exposure radiation dose, the glass dosimetry and Rando Phantom were used for 11 cancer patients with head circumference from March to October 2017 in order to assess the difference between mobile calibrations and the time taken from Set-up to shortly before IGRT. CBCT and ExacTrac System were used for IGRT of all patients. An average of 10 CBCT and ExacTrac images were obtained per patient during the total treatment period, and the difference in 6D Online Automation values between the two systems was calculated within the ROI setting. In this case, the area of interest designation in the image obtained from CBCT was fixed to the same anatomical structure as the image obtained through ExacTrac. The difference in positional values for the six axes (SI, AP, LR; Rotation group: Pitch, Roll, Rtn) between the two systems, the total time taken from patient set-up to just before IGRT, and exposure dose were measured and compared respectively with the RandoPhantom. Results: the set-up error in the phantom and patient was less than 1mm in the translation group and less than 1.5° in the rotation group, and the RMS values of all axes except the Rtn value were less than 1mm and 1°. The time taken to correct the set-up error in each system was an average of 256±47.6sec for IGRT using CBCT and 84±3.5sec for ExacTrac, respectively. Radiation exposure dose by IGRT per treatment was measured at 37 times higher than ExacTrac in CBCT and ExacTrac at 2.468mGy and 0.066mGy at Oral Mucosa among the 7 measurement locations in the head and neck area. Conclusion: Through 6D online automatic positioning between the CBCT and ExacTrac systems, the set-up error was found to be less than 1mm, 1.02°, including the patient's movement (random error), as well as the systematic error of the two systems. This error range is considered to be reasonable when considering that the PTV Margin is 3mm during the head and neck IMRT treatment in the present study. However, considering the changes in target and risk organs due to changes in patient weight during the treatment period, it is considered to be appropriately used in combination with CBCT.