• Title/Summary/Keyword: web shear

Search Result 353, Processing Time 0.026 seconds

Shear behavior of the hollow-core partially-encased composite beams

  • Ye, Yanxia;Yao, Yifan;Zhang, Wei;Gao, Yue
    • Steel and Composite Structures
    • /
    • v.44 no.6
    • /
    • pp.883-898
    • /
    • 2022
  • A hollow-core partially-encased composite beam, named HPEC beam, is investigated in this paper. HPEC beam comprises I-beam, longitudinal reinforcement, stirrup, foam formwork, and cementitious grout. The foam formwork is located on both sides of the web, and cementitious grout is cast within the steel flange. To investigate the shear performance of HPEC beams, static loading tests of six HPEC beams and three control beams were conducted. The shear span ratio and the number of studs on the shear behavior of the HPECspecimens were studied. The failure mechanism was studied by analyzing the curves of shear force versus both deflection and strain. Based on the shear span ratio (𝜆), two typical shear failure modes were observed: shear compression failure when 1.6 ≤ 𝜆 ≤ 2; and diagonal compression failure when 𝜆 ≤ 1.15. Shear studs welded on the flange can significantly increase the shear capacity and integrity of HPEC beams. Flange welded shear studs are suggested. Based on the deformation coordination theory and superposition method, combined with the simplified modified compression field model and the Truss-arch model, Modified Deformation Coordination Truss-arch (M.D.C.T.) model was proposed. Compared with the shear capacity from YB9038-2006 and JGJ138-2016, the calculation results from M.D.C.T. model could provide reasonable predictions.

A Study on the Seismic Reinforcement of a Low-Rise Building Using Sinusoidal Corrugated Web Members (사인파형 웨브주름 보강재를 이용한 저층건물의 내진보강에 관한 연구)

  • Jung, Dong Jo;Kim, Jin
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.24 no.2
    • /
    • pp.13-20
    • /
    • 2022
  • In this study, a general low-rise building was selected to compare the new shear wall reinforcement method, which is a general method among the existing reinforcement methods, and the reinforcement method using sinusoidal corrugated web reinforcement. And it was confirmed that the following effects can be expected. Sinusoidal corrugated web members can be carried out in a short period of time as it does not require the removal of the masonry filling wall, the reinforcement of reinforcing bars, and the curing period of the concrete. It is effective in preventing damage that may occur when masonry filling wall is overturned in the out-of-plane direction, and the burden of the foundation is also reduced, and thus the construction period and cost required for reinforcement can greatly be reduced. By adjusting the number of sinusoidal corrugated web member, details of joints, and reinforcement positions, the flow of load can be induced to have an advantageous effect on the building. It can be considered as the most suitable reinforcement plan in terms of life safety. Unlike the shear wall that fills between the columns, the sinusoidal corrugated web members, which has a width of 1.5m, can install openings between two columns depending on the purpose of use, and can be expected to have a great effect in terms of usability due to its free installation location. As mentioned above, the seismic reinforcement using a sinusoidal corrugated web members, can expect great effect compared to conventional reinforcement methods in terms of usability, economic feasibility, and stability.

Analytical Study of Shear Capacity of Trapezoidal Corrugated Web Girders (건축물 적용을 위한 제형 절곡 웨브 보의 전단성능에 관한 해석적 연구)

  • Lee, Seo Haeng;Park, Geun Woo;Yoo, Jung Han
    • Journal of Korean Society of Steel Construction
    • /
    • v.30 no.1
    • /
    • pp.49-58
    • /
    • 2018
  • This study conducted nonlinear finite element analysis to figure out the influence of shear performance on the ${\beta}$ of girders with trapezoidal corrugated web. Through the experiment specimen, analysis model which is highly accurate was verified. Based on this, a parameter analysis was conducted on key variables affecting ${\beta}$. Proposed formulas of previous studies were analyzed using parameter analysis result. Eurocode was designed to be safer than other proposals. Only models that are included in the inelastic area, depending on the Moon's proposal, were satisfied the proposed formulas by Kim to enhance economic design.

Ductility Capacity of Shear-Dominated Steel Plate Walls (전단지배 강판벽의 연성능력)

  • Park, Hong Gun;Choi, In Rak;Jeon , Sang Woo;Kim, Won Ki
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.4
    • /
    • pp.457-468
    • /
    • 2006
  • An experimental study was performed to investigate the maximum energy dissipation and the ductility capacity of shear-dominated steel plate walls with thin web plates. Three specimens of three-story plate walls with thin web plates were tested. The parameters for the test specimens were the aspect ratio of the web plate and the shear strength of the column. A concentrically braced frame and a moment-resisting frme were a also tested for comparison. The steel plate walls exhibited much better ductility and energy dissipation capacity than the concentrically braced frame and the moment-resisting frame. The results showed that unlike other structural systems, the sh as well as strength, and can therefore be used as an effective earthquake-resisting system. A method of predicting the energy dissipation capacity of a steel plate wall was proposed.

Cyclic behavior of steel beam-concrete wall connections with embedded steel columns (II): Theoretical study

  • Li, Guo-Qiang;Gu, Fulin;Jiang, Jian;Sun, Feifei
    • Steel and Composite Structures
    • /
    • v.23 no.4
    • /
    • pp.409-420
    • /
    • 2017
  • This paper theoretically studies the cyclic behavior of hybrid connections between steel coupling beams and concrete shear walls with embedded steel columns. Finite element models of connections with long and short embedded steel columns are built in ABAQUS and validated against the test results in the companion paper. Parametric studies are carried out using the validated FE model to determine the key influencing factors on the load-bearing capacity of connections. A close-form solution of the load-bearing capacity of connections is proposed by considering the contributions from the compressive strength of concrete at the interface between the embedded beam and concrete, shear yielding of column web in the tensile region, and shear capacity of column web and concrete in joint zone. The results show that the bond slip between embedded steel members and concrete should be considered which can be simulated by defining contact boundary conditions. It is found that the loadbearing capacity of connections strongly depends on the section height, flange width and web thickness of the embedded column. The accuracy of the proposed calculation method is validated against test results and also verified against FE results (with differences within 10%). It is recommended that embedded steel columns should be placed along the entire height of shear walls to facilitate construction and enhance the ductility. The thickness and section height of embedded columns should be increased to enhance the load-bearing capacity of connections. The stirrups in the joint zone should be strengthened and embedded columns with very small section height should be avoided.

Effects of Web Reinforcement Amount on Hysteretic Behavior of High Strength Reinforced Concrete Structural Walls (전단보강근비에 따른 고강도 철근콘크리트 내력벽의 이력특성)

  • 최근도;정학영;윤현도;최장식;이리형
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.04a
    • /
    • pp.85-90
    • /
    • 1994
  • Three high strength reinforced concrete structural walls were tested under the combined action of a constant axial and a horizontal cycle load. The aim of the tests has been to investigate the effects of the web horizontal reinforcement on hysteretic behavior of wall. The results have helped to identify the causes of wall failure and have demonstrated the web horizontal reinforcement does not appear have a significant effect on shear capacity, stiffness and energy dissipation but have a significant effect on the failure mode of the walls.

  • PDF

An Experimental Study on the Shear Behavior of Reinforced Concrete Deep Beams Subject to Concentrated Loads (집중하중을 받는 철근콘크리트 깊은 보의 전단거동에 대한 실험적 연구)

  • 송우석;이진섭;양창현;김상식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.273-278
    • /
    • 1994
  • The shear behavior of simply supported reinforced concrete deep beams subject to concentrated loads has been scrutinized experimentally to verify the influence of the structural parameters such as shear span ratio, and the horizontal and vertical web reinforcements. A total of 27 specimens has been tested at the laboratory. In the tests all specimens have failed in shear causing inclined cracks from the load application points to the supports. The load bearing capacities have changed significantly depending on the shear span ratio. The effects of the vertical and horizontal reinforcements on the shear strength and crack initiation and propagation have been carefully checked and analyzed.

  • PDF

The Shear-Properties of Reinforced Concrete Beams without Web Reinforcement (복부보강이 없는 철근콘크리트보의 전단특성)

  • 문제길;홍익표
    • Magazine of the Korea Concrete Institute
    • /
    • v.5 no.2
    • /
    • pp.151-161
    • /
    • 1993
  • 본 논문은 전단철근을 갖지 않는 비교적 짧은 지간의 철근콘크리트 보에서 전단특성을 규명하고 균열전단강도와 극한전단강도를 예측하기 위한 것으로 총30개의 보를 4 series로 나누어 실험을 수행하였다. 실험의 변수는 콘크리트의 강도, 전단지간-유효높이의 비, 인장철근량등이며, 실험과정을 통해 파괴형상, 처짐, 전단강도등을 측정하였다. 실험결과로부터 콘크리트의 강도가 커지고 철근량이 많아질수록, 그리고 전단지간이 짧아질수록 철근콘크리트 보의 균열 및 극한전단강도가 증가됨을 밝혔다. 또한, 실험성과를 회귀분석하여 균열전단강도와 극한전단강도 추정식을 제안하였다. 제안된 추정식에 의한 계산값과 실험성과를 비교 검토하여 그 상관성을 확인하였다.

A Study on the Shear Strength Evaluation of Reinforced Concrete Deep Beams subject to Concentrated Loads. (집중하중을 받는 철근콘크리트 깊은 보의 전단강도 평가에 관한 연구)

  • 양준호;이진섭;김상식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.577-582
    • /
    • 2000
  • This study is aimed to evaluate the shear strength of reinforced concrete deep beams subject to concentrated loads, using a simplified strut-tie model. For the shear strength prediction of deep beams, it is prerequisite to evaluate the effective width of strut and to verify the efficiency factors proposed by MacGregor et al.. The results analyzed by truss models have been compared with those calculated by domestic code for the existing data of 90 deep beam specimens. The shear strength of deep beams were reviewed with respect to concrete strength, the shear span-depth ratio, and the ratio of web reinforcements. The results showed that the shear strength of the proposed model gave a better agreement than the domestic code approach.

  • PDF

Design of composite plate girders under shear loading

  • Shanmugam, N.E.;Baskar, K.
    • Steel and Composite Structures
    • /
    • v.6 no.1
    • /
    • pp.1-14
    • /
    • 2006
  • Experiments have been carried out on six composite and two plain steel plate girders under shear loading to understand the elastic and inelastic behaviour of such girders. The failure mechanism assumed and used to develop design equations is normally based on the failure patterns observed in the experiments. Therefore, different types of cracks and failure patterns observed in the experiments are reviewed briefly first. Based on the observed failure patterns, a design method to predict the ultimate shear capacity of composite plate girders is proposed in this paper. The values of ultimate shear capacity obtained using the proposed design method are compared with the corresponding experimental values and it is found that the proposed method is able to predict the shear capacity accurately.