• Title/Summary/Keyword: waveform parameter

Search Result 129, Processing Time 0.026 seconds

Design of FPGA-based Signal Processing of EWRG for Localized Heavy Rainfall Observation (국지성 호우 관측을 위한 FPGA 기반의 전파강수계 신호처리 설계)

  • Choi, Jeong-Ho;Lee, Bae-Kyu;Park, Hyeong-Sam;Park, Jeong-Min;Lim, Sang-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.9
    • /
    • pp.1215-1223
    • /
    • 2020
  • Recently, the number of natural disasters caused by inclement weather conditions such as localized heavy rainfall, Typhoon, etc. is increasing in Korea, which requires relevant prevention and water management measures. Rain gauges installed on the ground have strengths in continuously·directly measures ground precipitation but cannot provide accurate information on spatial precipitation distribution in the areas without the rain gauges. The present research has designed and developed an electromagnetic-based multi-purpose precipitation gauge(EWRG, Electromagnetic Wave Rain Gauge) that can measure rainfall at the real time, by overcoming spatial representativeness. In this paper, we propose an FPGA-based signal processing design method for EWRG. The signal processing of the EWRG was largely designed by calculating the ADC and DDC of the LFM waveform, pulse compression, correlation coefficient and estimating the precipitation parameter. In this study, the LFM waveform and pulse compressed signal were theoretically analyzed.

Automatic Parameter Acquisition of 12 leads ECG Using Continuous Data Processing Deep Neural Network (연속적 데이터 처리 심층신경망을 이용한 12 lead 심전도 파라미터의 자동 획득)

  • Kim, Ji Woon;Park, Sung Min;Choi, Seong Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.2
    • /
    • pp.107-119
    • /
    • 2020
  • The deep neural networks (DNN) that can replicate the behavior of the human expert who recognizes the characteristics of ECG waveform have been developed and studied to analyze ECG. However, although the existing DNNs can not provide the explanations for their decisions, those trials have attempted to determine whether patients have certain diseases or not and those decisions could not be accepted because of the absence of relating theoretical basis. In addition, these DNNs required a lot of training data to obtain sufficient accuracy in spite of the difficulty in the acquisition of relating clinical data. In this study, a small-sized continuous data processing DNN (C-DNN) was suggested to determine the simple characteristics of ECG wave that were not required additional explanations about its decisions and the C-DNN can be easily trained with small training data. Although it can analyze small input data that was selected in narrow region on whole ECG, it can continuously scan all ECG data and find important points such as start and end points of P, QRS and T waves within a short time. The star and end points of ECG waves determined by the C-DNNs were compared with the results performed by human experts to estimate the accuracies of the C-DNNs. The C-DNN has 150 inputs, 51 outputs, two hidden layers and one output layer. To find the start and end points, two C-DNNs were trained through deep learning technology and applied to a parameter acquisition algorithms. 12 lead ECG data measured in four patients and obtained through PhysioNet was processed to make training data by human experts. The accuracy of the C-DNNs were evaluated with extra data that were not used at deep learning by comparing the results between C-DNNs and human experts. The averages of the time differences between the C-DNNs and experts were 0.1 msec and 13.5 msec respectively and those standard deviations were 17.6 msec and 15.7 msec. The final step combining the results of C-DNN through the waveforms of 12 leads was successfully determined all 33 waves without error that the time differences of human experts decision were over 20 msec. The reliable decision of the ECG wave's start and end points benefits the acquisition of accurate ECG parameters such as the wave lengths, amplitudes and intervals of P, QRS and T waves.

A Study on ACFBD-MPC in 8kbps (8kbps에 있어서 ACFBD-MPC에 관한 연구)

  • Lee, See-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.49-53
    • /
    • 2016
  • Recently, the use of signal compression methods to improve the efficiency of wireless networks have increased. In particular, the MPC system was used in the pitch extraction method and the excitation source of voiced and unvoiced to reduce the bit rate. In general, the MPC system using an excitation source of voiced and unvoiced would result in a distortion of the synthesis speech waveform in the case of voiced and unvoiced consonants in a frame. This is caused by normalization of the synthesis speech waveform in the process of restoring the multi-pulses of the representation segment. This paper presents an ACFBD-MPC (Amplitude Compensation Frequency Band Division-Multi Pulse Coding) using amplitude compensation in a multi-pulses each pitch interval and specific frequency to reduce the distortion of the synthesis speech waveform. The experiments were performed with 16 sentences of male and female voices. The voice signal was A/D converted to 10kHz 12bit. In addition, the ACFBD-MPC system was realized and the SNR of the ACFBD-MPC estimated in the coding condition of 8kbps. As a result, the SNR of ACFBD-MPC was 13.6dB for the female voice and 14.2dB for the male voice. The ACFBD-MPC improved the male and female voice by 1 dB and 0.9 dB, respectively, compared to the traditional MPC. This method is expected to be used for cellular telephones and smartphones using the excitation source with a low bit rate.

Impact of Group Delay in RF BPF on Impulse Radio Systems (임펄스 라디오 시스템에서 RF 대역 통과 필터의 군지연 영향 분석)

  • Myoung Seong-Sik;Kwon Bong-Su;Kim Young-Hwan;Yook Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.4 s.95
    • /
    • pp.380-388
    • /
    • 2005
  • This paper presents analysis results of the effects of RF filter characteristics on the system performance of impulse radio. The impulse radio system transmits modulated pulses having very short time duration and information can be extracted in receiver side based on cross-correlation between received and transmitted pulses. Accordingly, the pulse distortion due to in-band group delay variation can cause serious system performance degradation. In general, RF bandpass filters inevitably cause group delay difference to the signal passing through the filter which is proportional to its skirt characteristic due to its resonance phenomenon. For time as well as frequency domain analysis, small signal scattering parameter $S_{21}$ and its Fourier transform are used to characterize output pulse waveform under the condition that the input and output ports are matched. The output pulse waveform of the filter is predicted based on convolution integral between input pulse and filter transfer function, and resulting BER performances in the BPM and PPM based impulse radio system are calculated.

Extraction of Parameters for Acupoint Discrimination and Design of discrimination system (경혈식별을 위한 파라메터 추출 및 식별시스템의 설계)

  • 이용흠;박창규
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.1
    • /
    • pp.89-101
    • /
    • 2001
  • The conventional pattern-methods for discrimination of acupoint, meridian line which is the basic object of diagnosis and medical treatment in oriental medicine is discriminated the conduction point by the stimulation in body skin with DC. But, it is not sufficient to truth in discrimination ratio, coincident ratio, body effect, reproductivity. Therefore, this paper is extracting the optimal parameter of frequency and waveform in order to improve the conventional pattern, and proposing the SPAC(Single Power Alternative Current) stimulus pattern applying that. Also, this algorithm proposes to be able to discriminate with low pressure of the electrode by displaying in the level meter both the absolution and relation value of the skin current. It is able to decrease pain and body effect by electrode pressure and discriminate acupoint regardless of skin current in difficult discrimination spot. It is compared the performance of system applying the extracted optimal parameter and algorithm, and it is confirmed that there is difference in discrimination parameter of acupoint reacted to the individual and the meridian. It is compared that discrimination, coincident ratio of the traditional acupoints as the acupoint stimulation pattern. It is confirmed truth of optimal parameter and discrimination algorithm. Keyword: Meridian, Discrimination, Coincident, Body effect, Reproductivity, SPAC, Optimal parameter.

  • PDF

Waveform Changes of the Radial Pulsation Followed by the Food Intakes in Healthy Subjects (식사에 따른 맥상파 변화 연구 -h1, t, 맥(脈)에너지, RAI를 중심으로-)

  • Kim, Gyeong-Cheol;Lee, Jeong-Won;Ryu, Gyeong-Ho;Kim, Yi-Soon
    • Korean Journal of Oriental Medicine
    • /
    • v.17 no.3
    • /
    • pp.87-96
    • /
    • 2011
  • Objectives : The study on the affected factor of the pulse wave is important in the pulse wave part. The purpose of this study is to secure the objective data of pulse-wave parameter on the food intakes affected the radial pulse-wave. Methods : The study was carried out healthy adult men. We researched the blood circulation index and the changes of the pulse factor according to 'before meal', 'right after meal', '30 minute after meal', '1 hour after meal' and '2 hours after meal'. We analyzed the changes according the time schedule. And analyzed the difference between 'before meal' and 'after meal'on the pulse-wave parameter. Results : The results were as follows. 1. HR, ECO and ECI were showed the highest increase 'after meal' and the significant decrease in '2 hours after meal' with 'before meal' degree. 2. In the pulse energy, 'left hand average pulse energy' was showed the highest increase 'after meal', and 'right hand average pulse energy' and 'right Quan(關)' were showed the highest increase in '30 minute after meal'. 3. h1 of '6 part of left and right hand'(Chon-Quan-Chuk, 寸關尺) was showed the significant difference statistically in 'left Chuk' and 'right Quan'. 4. T was showed the highest 'before meal' and the lowest after meal in '6 part of left and right' (Chon-Quan-Chuk, 寸關尺). 5. RAI was showed the highest 'before meal' in '6 part of left and right'(Chon-Quan-Chuk 寸關尺). Conclusions : From the about results, the food intakes was considered important factor of pulse formation. On the factor affected the pulse, we considered that continuous study needs for the future.

Open and Short Circuit Switches Fault Detection of Voltage Source Inverter Using Spectrogram

  • Ahmad, N.S.;Abdullah, A.R.;Bahari, N.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.2
    • /
    • pp.190-199
    • /
    • 2014
  • In the last years, fault problem in power electronics has been more and more investigated both from theoretical and practical point of view. The fault problem can cause equipment failure, data and economical losses. And the analyze system require to ensure fault problem and also rectify failures. The current errors on these faults are applied for identified type of faults. This paper presents technique to detection and identification faults in three-phase voltage source inverter (VSI) by using time-frequency distribution (TFD). TFD capable represent time frequency representation (TFR) in temporal and spectral information. Based on TFR, signal parameters are calculated such as instantaneous average current, instantaneous root mean square current, instantaneous fundamental root mean square current and, instantaneous total current waveform distortion. From on results, the detection of VSI faults could be determined based on characteristic of parameter estimation. And also concluded that the fault detection is capable of identifying the type of inverter fault and can reduce cost maintenance.

A Prediction Model for Low Cycle and High Cycle Fatigue Lives of Pre-strained Fe-18Mn TWIP Steel (Fe-18Mn TWIP강의 Pre-strain에 따른 저주기 및 고주기 피로 수명 예측 모델)

  • Kim, Y.W.;Lee, C.S.
    • Transactions of Materials Processing
    • /
    • v.19 no.1
    • /
    • pp.11-16
    • /
    • 2010
  • The influence of pre-strain on low cycle fatigue behavior of Fe-18Mn-0.05Al-0.6C TWIP steel was studied by conducting axial strain-controlled tests. As-received plates were deformed by rolling with reduction ratios of 10 and 30%, respectively. A triangular waveform with a constant frequency of 1 Hz was employed for low cycle fatigue test at the total strain amplitudes in the range of ${\pm}0.4\;{\sim}\;{\pm}0.6$ pct. The results showed that low-cycle fatigue life was strongly dependent on the amount of pre-strain as well as the strain amplitude. Increasing the amount of prestrain, the number of reversals to failure was significantly decreased at high strain amplitudes, but the effect was negligible at low strain amplitudes. A new model for predicting fatigue life of pre-strained body has been suggested by adding ${\Delta}E_{pre-strain}$ to the energy-based fatigue damage parameter. Also, high-cycle fatigue lives predicted using the low-cycle fatigue data well agreed with the experimental ones.

Evaluation on Corrosion of A106 Carbon Steel using AE Technique (음향방출기법을 이용한 A106 탄소강의 부식평가)

  • Lee, Jin-Kyung;Lee, Sang-Pill
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.5
    • /
    • pp.100-105
    • /
    • 2008
  • A106 Carbon Steel has recently been used as the material for pipes, nozzles, and tank shells in nuclear power plants. Its corrosion resistance gives the steel many advantages for use in structures under high temperature and high pressure. This steel is also expected to be used as a structural material in the shipbuilding industry for applications involving severe conditions, such as high temperature and pressure. In this study, the mechanical properties of A106 carbon steel were evaluated in regard to its corrosion times. The tensile and yielding strengths decreased as the corrosion time increased. In particular, the tensile strength was influenced by corrosion. In addition, an acoustic emission (AE) technique was used to clarify the microscopic damage to specimens that had undergone corrosion for a certain period. It was found that AE parameters, such as events, energy, duration time, and amplitude were useful for evaluating the degree of damage and remaining life of the corroded specimen. Various properties of the waveform and frequency range were also seen, based on the degree of damage to the specimen from the corrosion time.

Design of Double Digital Controller to Improve Performance for the Silent Discharging Ozonizer (무성방전 오조나이저의 성능개선을 위한 2중 디지털 제어기의 설계)

  • Park, Jee-Ho;Kim, Dong-Wan;Woo, Sung-Hoon;Roh, In-Bae;Woo, Jung-In
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.1
    • /
    • pp.13-20
    • /
    • 2006
  • In this paper, a control method of ozone generator for a tiny deodorizer is proposed, and also a cooling technique is described which is cooling down the flowing air gap into a silent discharger to $2[^{\circ}C]$ to generate ozone of high density and diffusing power. As the digital control system for this method, a double feedback loop is designed which detects the voltage and current of equivalent capacitor of the discharger and compensates for the poor power waveform caused by the noise at high discharging frequency. During the plant modeling of this system, computing time factor is considered as a unique parameter of the power system to improve the respond characteristics with regard to fluctuating load and to replenish the computing time delay of the controller. Through the experiment, sinusoidal input current for discharger can be acquired and all the effectiveness of this accurate control system over unstable ozone discharger are proved.