• Title/Summary/Keyword: wave treatment

Search Result 567, Processing Time 0.027 seconds

The Effect of Home Care Hair Treatment on Hair during Permanent Wave Treatment (홈케어 헤어 트리트먼트 처리에 따른 퍼머넌트 웨이브 시술시 모발에 미치는 영향)

  • Lee, Bo-Ram;Ko, Kyoung-Sook
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.10
    • /
    • pp.270-276
    • /
    • 2021
  • The purpose of this study was to investigate the effects of home care hair treatment characteristics and frequency on hair during permanent wave treatment. The hair treatments distributed on the market were classified into cationic surfactants and silicone oil. Hair treatment was performed 5 times, 10 times, 20 times differently according to the frequency of use, and hair permanent wave was performed. The hair thickness, tensile strength, epidermal observation using SEM, and hair component analysis using EDS were performed as experimental methods. The results of the experiment showed that the natural-derived ingredient was the main ingredient, and the cationic surface activity and silicon oil-free product group had high hair protection effect. Therefore, the product group using natural ingredients should be further researched and developed, and the study on the method and frequency of use of products with irritant chemical ingredients should be conducted.

Physical and Morphological Characteristics Change of Hair according to Water Content when Heat Permanent Wave is treated (열펌 시술시 수분함량에 따른 모발의 물리적·형태학적 특성 변화)

  • Lee, Soon-Hee;Kim, Sung-Nam
    • Fashion & Textile Research Journal
    • /
    • v.10 no.3
    • /
    • pp.389-393
    • /
    • 2008
  • The purpose of this study is to provide beauticians with the fundamental material for them to use effectively heat permanent wave and satisfy their customers. It carried out an experiment with hair of a woman in her late twenties to investigate the change of physical and morphologic characteristics by its water content when performing heat permanent wave. It evaluated the water content as 0g, 1g, 2g, 3g and 4g respectively when performing the heat permanent wave on hair, then it compared and observed the wave type, tensile strength and elongation for its physical change also observed the morphologic change by scanning electronic microscope and transmission electronic microscope. The result of experiment on the physical specificity revealed that the wave was the most ideal when the water content was 2 g. The material with much water content made wave but the result was not satisfied. In the case of hair with water content of nearly 0g didn't make wave. In terms of tensile strength and elongation, the tensile strength was generally reduced as hair was damaged, on the contrary, the elongation was increased. It observed the change of morphologic characteristic and got the result that the damage on hair cuticle was deepen as its water content was decreased. It also showed the result that damage happened on hair cuticle more than hair cortex with the observation of fine structure on hair section by transmission electronic microscope. Generally chemical treatment damaged hair. Under consideration of this aspect, the ultimate goal of this thesis is to minimize the damage of hair caused by chemical treatment and get the satisfaction on the hair style. The result of experiment presented that the hair showed the best result when its water content was 2 g.

Ayurvedic Shiro-Abhyanga and Relaxation of women's stress (아유르베딕 시로아비앙가가 성인여성의 스트레스 완화에 미치는 영향)

  • Choi, Jung-Myung;Choi, Yoon-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1800-1805
    • /
    • 2008
  • Shiro-abhyanga is one of treatments of Ayurveda, which is the ancient system of health care and medicine in India. In this essay, I examined the effect of Shiro-abhyanga for relaxing stress of women in twentieth by the means of the brain wave test. The brain wave test showed that Shiro-abhyanga reduced Delta and Theta waves of the left brain but increased $\alpha$, SMR, Low-$\beta$ waves of the right brain. Delta and Theta waves are usually found in sleeping time. Their high measurement in awakening instructs the stress and depressing situations of objects. However the treatment of Shiro-abhyanga made the decrease of Delta and Theta waves and the increase of Alpha wave in working time. Alpha wave appears while objects are comfortable and peaceful from the relaxation of body and mind. Therefore the growth of Alpha wave says that the treatment of Shiro-abhyanga has an effect on mitigation of stress.

The Effects of Blood Circulation and Skin Temperature by Ultrasound (초음파가 혈류량 및 피부온도에 미치는 영향)

  • Oh Min-Young;Jang Chel;Kim Hyun-jung
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.4
    • /
    • pp.179-201
    • /
    • 2004
  • The purpose of this study was to determine the effect of application methods in ultrasound on skin temperature and muscle blood flow. Thirty healthy volunteers without known vascular problems participated and randomly divided into three groups such as continuous wave group (CWG) which received a ultrasound treatment of continuous-wave, intermittent wave group (IWG) which received a ultrasound treatment of intermittent-wave at a dosage of $1.5\;W/cm^2$ for a duration of 5 minutes, and placebo group (PG) which received a ultrasound treatment of no-wave and no-dosage ultrasound to the anterior forearm. Blood flow and skin temperature was measured using MP 150 before and after ultrasound administration. The results were as follows : 1. Administration of ultrasound in all groups had increased effect on skeletal muscle blood flow immediately after treatment and for up to 10 minutes posttreatment. 2. CWG and IWG showed increased skin temperature immediately after a ultrasound administration and maintained to 10 minutes posttreatment. PG showed increased skin temperature immediately after a ultrasound administration but returned to initial state to 10 minutes posttreatment. 3. The great change on skeletal muscle blood flow among three groups showed in CWG ($6.27{\pm}1.72$) and then displayed in PG ($5.12{\pm}1.66$) and IWG ($4.61{\pm}2.19$) in order. 4. The vast change on skin temperature among three groups showed in CWG and then IWG and PG in order.

  • PDF

Nondestructive Evaluation for Long-term Heat Treatment Effects on Microstructure of Co-base Superalloy by Scanning Acoustic Microscope (주사음향현미경을 이용한 코발트기 초내열합금 미세조직에 관한 장시간 열영향에 대한 비파괴평가)

  • lEE, JoonHee;Kim, ChungSeok
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.32 no.3
    • /
    • pp.118-123
    • /
    • 2019
  • The aim of this study investigates the feasibility of scanning acoustic microscope (SAM) with high frequency transducer for material degradation. The test specimen was prepared by artificial heat treatment of Co-base superalloy. The high frequency 200 MHz acoustic lens was used to generate the leaky surface acoustic wave (LSAW) on the test specimens. The matrix precipitates coarsened with thermal aging time, and then grow up to several tens of micrometers. The velocity of LSAW decreased with increasing aging time. Also, it has a good correlation between LSAW and hardness. Consequently, V(z) curve methods of SAM using high frequency transducer is useful tool to evaluate the heat treatment effects on microstructure.

Application of Pulsed Electric Fields with Square Wave Pulse to Milk Inoculated with E. coli, P. fluorescens, and B. stearothermophilus

  • Shin, Jung-Kue;Jung, Kwan-Jae;Pyun, Yu-Ryang;Chun, Myong-Soo
    • Food Science and Biotechnology
    • /
    • v.16 no.6
    • /
    • pp.1082-1084
    • /
    • 2007
  • Ultra-high temperature (UHT) processed full fat milk inoculated with Escherichia coli, Pseudomonas fluorescens, and Bacillus stearothermophilus was exposed to 30-60 kV/cm square wave pulsed electric field (PEF) with $1\;{\mu}sec$ pulse width, and $26-210\;{\mu}sec$ treatment time in a continuous PEF treatment system. Eight log reduction was obtained for E. coli and P. fluorescens and 3 logs reduced for B. stearothermophilus under PEF treatment conditions of $210\;{\mu}sec$ treatment time, 60 kV/cm pulse intensity at $50^{\circ}$. There was no significant change in pH and titration acidity of milk after PEF treatment. The electrical energy required to achieve 8 log reduction for E. coli and P. fluorescens was estimated to be about 0.74 kJ/L.

Development portable hair removal applies PET ($Pause^{10-90}$ and $Energy^{20-40}$ $Trigger^{1-7}$) function

  • Kim, Whi-Young
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.2
    • /
    • pp.223-230
    • /
    • 2009
  • For pulse trigger way and the energy injection rate according to PET ($Pause^{10-90}$ $Energy^{20-40}$ $Trigger^{1-7}$) function, indeed, human body condition, period of dormancy in this research about this back correctly adjustment possible and designed harmless micro carrying along style hair exclusion so that can design and manufacture and run special quality examination and Xenon flash lamp to crawl in human body. Because creating individual's skin model to do stable treatment by light transmission way by skin impedance and measure, must embody treatment special quality of most suitable that draw skin color, energy, wave length, approximately, transmission time, pulse delay etc. and want. Specially, saved standard of war treatment pulse modeling by skin impedance, and manufacture pulse modeling system of most suitable by skin subordinate, and embody suitable treatment pulse. Specially, embody as could do root of a hair exclusion being emitted in pulse form using multi wave length of 560nm, 590nm, 640nm, 755nm and embodied clinical data. If become research repletion furthermore little more, is seen that can approximate in commercialization.

Dielectric/Magnetic Nanowires Synthesized by the Electrospinning Method for Use as High Frequency Electromagnetic Wave Absorber

  • Jwa, Yong-Ho
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.14-14
    • /
    • 2009
  • High frequency electromagnetic(EM) waves are increasingly being applied in industries because of saturationat lower frequency bands as a result of huge demand. However, electromagneticinterference (EMI) has become a serious problem, and as a result, highfrequency EM absorbers are now being extensively studied. Also, recentdevelopments in absorber technology have focused on producing absorbers thatare thin, flexible, and strong. Hence, one-dimension ferrous nano-materials area potential research field, because of their interesting electronic andmagnetic properties. Commercially, EM wave absorbing products are made ofcomposites, which blend the insulating polymer with magnetic fillers. Inparticular, the shape of the magnetic fillers, such flaky, acicular, or fibrousmagnetic metal particles, rather than spherical, is essential for synthesizingthin and lightweight EM wave absorbers with higher permeability. High aspectratio materials exhibit a higher permeability value and therefore betterabsorption of the EM wave, because of electromagnetic anisotropy. Nanowires areusually fabricated by drawing, template synthesis, phase separation, selfassembly, and electrospinning with a thermal treatment and reduction process.Producing nanowires by the electrospinning method involves a conventionalsol-gel process that is simple, unique, and cost-effective. In thispresentation, Magnetic nanowire and dielectric materials coated magneticnanowire with a high aspect ratio were successfully synthesized by theelectrospinning process with heat treatment and reduction. In addition toestimating the EM wave absorption ability of the synthesized magnetic anddielectric materials coated magnetic nanowire with a network analyzer, weinvestigated the possibility of using these nanowires as high-frequency EM waveabsorbers. Furthermore, a wide variety of topics will be discussed such as thetransparent conducting nanowire and semiconducting nanowire/tube with theelectrospinning process.

  • PDF