• Title/Summary/Keyword: wave treatment

Search Result 567, Processing Time 0.034 seconds

A Case Of Myelodysplastic Syndrome (골수이형성증후군(骨髓異形成症候群) 환자(患者) 일례(一例)에 대한 증례(症例) 보고(報告))

  • Kim, Jong-Dae
    • The Journal of Internal Korean Medicine
    • /
    • v.20 no.1
    • /
    • pp.274-279
    • /
    • 1999
  • In order to look about the effect and possibility of oriental medical diagnosis and treatment of pancytopenia of myelodysplastic syndrome. For a patient who has pancytopenia. we diagnose him as myelodysplastic syndrome by CBC, LFT, Ultrasonic wave, Vitamin B12 test, Bone marrow test, Folic acid test and doing Herb-medication, Moxa-Tx continually, we observed the change of WBC, RBC. HGB. MCV, Platelet. ESR with following up CBC test ten times Finally, WBC increased by 900, RBC increased by 400000, MCV was reduced by 7fl. HGB increased by 1.3g/dl. Hct increased by 3.2%, ESR was reduced from 127 to 35mm/h. We diagnosed myelodysplastic syndrome as 'CONSUMPTIVE DISEASE' in oreintal medicine. The treatment effect of pancytopenia was achieved by Herb-medication and Moxa-Tx for invigorating qi, enriching the blood, invigorating the spleen and the kidney-yang, Now we need the study of oriental medical treatment for Aplastic Anemia and AML which is similar this.

  • PDF

Study on the Bonding Process between Thin film and Piezoelectric Materials (박막과 압전 재료 결합에 관한 연구)

  • Chong, Woo-Suk;Kim, Gi-Beum;Hong, Chul-Un
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.11
    • /
    • pp.1014-1018
    • /
    • 2005
  • The purpose of this study is to obtain strong bond strength at the interface between piezoelectric substrates and semiconductor thin films to be applied for the manufacture of high-performance acoustic wave semiconductor coupled device. For this purpose, we have compared and examined the effects of different surface treatment methods on hydrophile properties at the surface of the piezoelectric substrates. Moreover, we have observed the effect of microwave and laser on the elimination of water molecules at the interface. As for the piezoelectric substrates, dry method for surface treatment was found to be superior in the control of hydrophilicity of the surface compared to wet method. On the other hand, both microwave and laser were found to be effective in the elimination of water molecules in the interface.

A Study on Improvement of Fatigue Strength of Electrical Panel Weldments in Naval Vessels by Post Weld Treatment (함정용 배전반 용접부의 용접후처리 방법에 의한 피로강도 증대 효과에 관한 연구)

  • Kim, Myung-Hyun;Kang, Min-Su;Kang, Sung-Won
    • Journal of Welding and Joining
    • /
    • v.26 no.4
    • /
    • pp.55-60
    • /
    • 2008
  • Structural reliability of electrical panels installed in naval vessels is of critical importance from structural performance viewpoint. The panels may be exposed to vibration and fatigue loadings from internal and external sources and wave loading which cause fatigue cracking. In this study, common methods such as burr grinding and post weld heat treatment (PWHT), for the fatigue strength improvement of weldments are investigated. Burr grinding is carried out using a electric grinder in order to remove surface defects and improve the weld bead profile. And also PWHT is carried out for the purpose of removing residual. The effectiveness of the two post treatment methods is evaluated in terms of fatigue strength improvement of welded structures.

A Study on the Deposition Characteristics of ZnO Piezoelectric Thin film Bulk Acoustic Resonator (FBAR 응용을 위한 ZnO 압전 박막의 증착 특성에 관한 연구)

  • 최승혁;김종성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.8
    • /
    • pp.716-722
    • /
    • 2003
  • ZnO thin films were deposited on Al and Pt electrodes by an RF reactive sputtering system for the fabrication of FBAR (film bulk acoustic wave resonator), and the effect of thermal treatment temperature on their c-axis preferred orientation was investigated. SEM experiments show that columnar structure of ZnO thin films were grown with c-axis normal to electrode material, and XRD experiments show that both ZnO films were grown with (002) plane preferred orientation, but larger diffraction peak was observed with Pt electrode. The peak intensity increased with higher thermal treatment temperature, but c-axis preferred orientation was diminished. The surface roughness of Al thin film was higher than that of Pt, and these affect the surface roughness of ZnO film deposited on the electrode. Though the preferred orientation with respect to Pt(111) plane was improved with higher thermal treatment temperature, this could not improve the c-axis orientation of ZnO film.

Deinking of White Ledger with Ultrasonic Wave : Laboratory Scale Trial

  • Won, Jong Myoung
    • Journal of Forest and Environmental Science
    • /
    • v.23 no.2
    • /
    • pp.73-78
    • /
    • 2007
  • Ultrasonic deinkings of white ledger were carried out to confirm whether the ink removal efficiency and pulp qualities can be improved by the ultrasonic deinking. The effects of conventional pulping and ultrasonic treatment of white ledger on the ink particle size distribution and ink removal coefficient were compared. The physical properties of paper, energy consumption and effluent qualities were measured. The ultrasonic treatment of white ledger resulted in the ink particle size distribution suitable for flotation. The ink removal efficiency, brightness, breaking length and effluent quality were improved by the ultrasonic deinking. It is expected that the competitiveness of ultrasonic deinking system can be improved by the optimization of treatment condition.

  • PDF

Finite Element Analysis of Pressure Distribution by Ultrasound in Human Thigh Model (대퇴부 모델에서의 초음파 압력분포에 관한 유한요소 해석)

  • Choi, Ho-Seon
    • The Journal of Information Technology
    • /
    • v.8 no.1
    • /
    • pp.43-50
    • /
    • 2005
  • Quantitative analysis for distribution of penetrating ultrasound in vivo is very important to determine the treatment region and method. In this paper, we constructed a simplified 2-D femoral region model that consists of skin-fat-muscle-bone layered system, and simulated the pressure distribution in the model in case of applying ultrasound using Finite Element Method(FEM). The ultrasound used in the simulation was assumed to be pulse wave and the pressure distribution was analyzed during only one period of pulse wave. In order to find the penetration depth, amplitude of pressure and sphere that ultrasound reaches in the model, we performed the simulation with varying the applied frequency, transducer size and amplitude of transducer's output. The result showed that applied frequency is inversely proportional to the penetration depth and amplitude of pressure but the amplitude of transducer's output is proportional to the amplitude of pressure in the model. Also, the sphere that ultrasound reaches was widened and the amplitude of pressure became larger as the transducer size became larger. This results were similar to that obtained from the previous model consisting of fat-muscle-bone layered system, but we observed that the pressure of ultrasound is decreased due to the decrements of pressure by the absorption coefficient of skin and the interference that depends on the reflection of ultrasound caused by the difference of acoustic impedance of skin and fat. Finally, we can infer that the model proposed in this study is closer to the realistic model than the previous ones. It shows that the results obtained from this study can be useful in designing the ultrasound treatment instrument or in setting up the treatment plan.

  • PDF

The Effect of Electroacupuncture at the PC6 (Naegwan) on the EEG (내관 전침 자극이 뇌파에 미치는 영향)

  • Lee, Tae-Young;Kim, Young-An;Lee, Kwang-Gyu;Yuk, Sang-Won;Lee, Chang-Hyun;Lee, Sang-Ryong
    • Journal of Acupuncture Research
    • /
    • v.19 no.3
    • /
    • pp.26-40
    • /
    • 2002
  • Objective : The aim of this study was to examine the effects of electroacupuncture(EA) at the PC6 (Naegwan) on nomal humans using power spectrum analysis. Methods : Electroencephalogram(EEG) is a multi-scaled signal consisting of several components of time series with different dominant frequency ranges and different origins. EEG power spectrum exibit site-specific and state-related differences in specific frequency bands. In this study, power spectrum was used as a measure of complexity. 30 channel EEG study was carried out in 8 subjects (8 males; age=$21.4{\pm}0.5$ years). Results : We found that the power values of the alpha wave at F7 channel (P<0.05) were highered than during the acupuncture treatment, and the power values of the delta wave at TCP1, CP1, TCP2, T5 channels(P<0.05) were lowered than during the acupuncture treatment. However, the comparison with that before and after the treatment shows no significant differences in all channels.

  • PDF

Inspection on the acoustic output of the focused extracorporeal focused shock wave therapeutic devices approved by MFDS (식약처에서 허가된 집속형 ESWT 치료기의 음향 출력 분석)

  • Choi, Min Joo;Jeon, Sung Joung;Kwon, Oh Bin;Lee, Min Young;Cho, Jin Sik;Kim, Han Soo;Maeng, Eun Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.4
    • /
    • pp.303-317
    • /
    • 2020
  • Extracorporeal Shock Wave Therapy (ESWT) is an innovative treatment in chronic musculoskeletal pain management and cardiovascular diseases. In this study, we surveyed the acoustic shock wave outputs from the domestically used focal type ESWT devices. The survey data were collected through 30 technical documents registered to the Ministry of Food and Drug Safety (MFDS), Rep. Korea. The results show that the focusing geometry varies largely, 5 mm to 65 mm in the focal length, 3 mm to 30 mm in focal width, and 4 mm to 108 mm in focal depth. The maximum positive pressure (P+) ranges from 7 MPa to 280 MPa, the focal Energy Flux Density (EFD) from 0.0035 mJ/㎟ to 35 mJ/㎟, and the energy per pulse (E) from 0.737 mJ to 80.86 mJ. All domestic PE-type (five) and one EM-type domestic devices included in the analysis of the correlation between P+ and EFD are shown to be far beyond the usual ranges and do not comply with expected correlation so that the reliability of their data was suspected. For the suspected, post-performance tests are required by a recognized testing agency. MFDS guidelines need to be revised so that the pass criteria for the shock wave acoustic outputs can be based on the clinical tests for indications.

Research about design and manufacture of own nerve system for core formation rehalititation treatment (근조직 재활치료를 위한 자기신경 시스템의 설계 및 제작에 관한 연구)

  • Kim, Whi-Young;Choe, Jin-Yeong;Park, Seong-Jun;Kim, Jin-Yeong;Park, Seong-Jun;Kim, Hui-Je
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2171-2172
    • /
    • 2006
  • Magnetic nerve stimulation treatment is much backward real condition than other field. Specially, successful medical treatment introduction of magnetic field (MF) can was refered long ago in Avicenna's work, and is thought as age of medicine magnetology development recently. These development is achieved through biologist and biophysicist and clinician's joint effort, but, new mountings and relationship air tassel are developed steadily. Magnetic nerve stimulation treatment field designs treatment system by each function during long wave high-amplitude (traditional magneto therapy of greatly great that strong that) short time that CMF, VMF, PMF field etc. are representative but are HPMT technology in this research and manufacture and special quality did comparative analysis.

  • PDF

Research about design and manufacture of Crossing High-Amplitude Magneto-Therapy own nerve system for nervous tissue rehalibitation treatment (신경조직 재활치료를 위한Crossing High-Amplitude Magneto-Therapy 자기신경 시스템의 설계 및 제작에 관한 연구)

  • Kim Whi-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.7 no.3
    • /
    • pp.263-270
    • /
    • 2006
  • Magnetic nerve stimulation treatment is much backward real condition than other field. Specially, successful medical treatment introduction of magnetic field (MF) can was refered long ago in Avicenna's work, and is thought as age of medicine magnetology development recently. These development is achieved through biologist and biophysicist and clinician's joint effort, but, new mountings and relationship air tassel are developed steadily. Magnetic nerve stimulation treatment field designs treatment system by each function during long wave high-amplitude (traditional magneto therapy of greatly great that strong that) short time that CMF, VMF, PMF field etc. are representative but are HPMT technology in this research and manufacture and special quality did comparative analysis.

  • PDF