• Title/Summary/Keyword: waterworks

Search Result 285, Processing Time 0.033 seconds

A Study of the 3D Unmanned Remote Surveying for the Curved Semi-Shield Tunneling

  • Lee, Jin-Yi;Jun, Jong-Woo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1791-1796
    • /
    • 2005
  • Semi-shield tunneling is one of the propulsion construction methods used to lay pipes underground between two pits named 'entrance' and 'destination', respectively. Usually a simple composition, such as 'a fiducial target at the entrance+a total station (TS)+a target on the machine', is used to confirm the planned course. However, unavoidable curved sections are present in small-sized pipe lines, which are laid after implementation of a road system, for public works such as waterworks, sewer, electrical power, and gas and communication networks. Therefore, if the planned course has a curved section, it is difficult to survey the course with the abovementioned simple composition. This difficulty could be solved by using the multiple total stations (MTS), which attaches the cross type linear LED target to oneself. The MTS are disposed to where each TS can detect the LED target at the other TS or the base point or the machine. And the accurate relative positions between each MTS and target are calculated from measured data. This research proposes the relative and absolute coordinate calculation algorithm by using three MTS to measure a curved course with 20m curvature at 30m maximum distance, and verifies the algorithm experimentally.

  • PDF

Design of Real Time Complex Proportion Method Automatic Chlorine Input System using RTOS (RTOS를 이용한 실시간 복합비례방식 자동 염소투입기 시스템 설계)

  • Kim, Si-Hwan;Lin, Chi-Ho
    • Journal of IKEEE
    • /
    • v.6 no.2 s.11
    • /
    • pp.146-151
    • /
    • 2002
  • This paper proposes a method that regulate a chlorine density to real time using RTOS. The most of a cleaning bed make use of the flux method to input chlorine. But, This method is difficult to control of chlorine's amount because Amount used of water is difference in each time or according to season. In this paper, we have designed a two method to flux and remain chlorine. Each task is programmed to cope with changeable external environment. The efficiency of the proposed system is shown by comparison results for performance of the proposal system with cleaning bed using a flux method.

  • PDF

DENTAL FLUOROSIS RESULTING FROM WATERWORKS CONTAINING EXCESS FLUORIDE : CASE REPORTS (과량의 불소가 함유된 상수도에 의한 반점치의 발생 : 증례보고)

  • Lee, Won-Ju;Park, Ho-Won;Lee, Ju-Hyun;Seo, Hyun-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.4
    • /
    • pp.744-749
    • /
    • 2008
  • Fluoride is a very effective element that can help prevent dental caries. The most economical and safest way of using fluoride is to add fluoride to the tap water. However, care must be taken to maintain the adequate concentration of fluoride in drinking water by regular check-up. Unless, dental fluorosis may occur. We are presenting a case of concurrent occurrence of fluorosis in people living in the same village in Korea, where drinking water contained high concentration of fluoride.

  • PDF

Characteristics of Disinfection By-Products Formation in Chlorination of Principal Raw Waters for Drinking Water of Jeju Island, Korea

  • Oh, Sun-Mi;Park, Tae-Hyun;Lee, Min-Gyu;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.21 no.9
    • /
    • pp.1031-1041
    • /
    • 2012
  • This study was carried out to investigate the characteristics of disinfection by-products (DBPs-trihalomethanes (THMs), haloacetic acids (HAAs) and haloacetonitriles (HANs) formation in chlorination of principal raw waters used for drinking water on Jeju Island, Korea. The domestic water supply of other area and humic acid solution (HA) were used as a reference point. The effects of chlorine contact time, solution temperature and pH on DBPs formation potential (DBPFP) were investigated for raw waters. In addition, the effect of $Br^-$ was studied for HA. The DBPFP (THMFP, HAAFP and HANFP) were increased with increasing chlorine contact time. Comparing the individual DBPFPs for raw waters, they decreased in the order of HAAFP > THMFP ${\geq}$ HANFP. As the solution temperature was increased, the THMFP, HAAFP and HANFP increased. With increasing the solution pH, the THMFP was increased, but HAAFP and HANFP were decreased. With the addition of 0.3 mg/L $Br^-$ for HA, the DBPFP was increased and the major chemical species changed: from trichloromethane to dibromochloromethane and tribromomethane for THMs; from dichloroacetic acid and trichloroacetic acid to tribromoacetic acid for HAAs; and from dichloroacetonitrile to dibromoacetonitrile for HANs.

A Proposition of Regional Development Planning in Defining the Analytical Relationship between Industrial Characteristics of Rural Areas and Aged Population Index (농촌지역의 산업특성과 인구노령화의 상관성 분석을 통한 지역산업개발방향 제시에 관한 연구)

  • Suh, Kyo;Lee, Ji-Min;Han, Yi-Chul;Lee, Jeong-Jae;Yoon, Seong-Soo
    • Journal of Korean Society of Rural Planning
    • /
    • v.10 no.2 s.23
    • /
    • pp.1-6
    • /
    • 2004
  • This study tried to construct a direction in regional planning concerning the structural relationship between the ratio of aged population and the industrial characteristics. We investigated this structural relationship incorporating the aged population index and the number of classified companies. We applied diverse statistical analyses to understand the relationship. We classified the number of companies to reflect regional industrial characteristics using the principal component analysis. We applied a multiple regression model to understand the relationship between these two indices. The aged population index represents the degree of being old divided by the ratio of juvenile population and aged population. We found that such industries as manufacturing, service, and conveyance increase the ratio of juvenile population. However, industries such as tourism, waterworks, forestry, agriculture and etc. have a positive effect on the aged population index. In addition to these findings, we believe that the efficacy of this study is the possibility that can be used as the basic data when central or local autonomous entities need to adopt rural development planning.

Design criteria of Hazen-Williams C value of water pipe system (상수관로의 유속계수 설계기준)

  • Kwon, Hyuk Jae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.6
    • /
    • pp.659-666
    • /
    • 2015
  • In this study, Hazen-Williams C value of pipes in wide waterworks system was estimated and statistically analyzed. Hazen-Williams C value of water pipe was predicted after 20 years of service period. From the results, it was found that C value of water pipe for treated water maintained higher value of 110 after 20 years of installation. Furthermore, it was found that velocity coefficients of steel pipe for less than and more than 20 years of installation were 117.7 and 109.3, respectively. C value of ductile iron pipe for less than and more than 20 years of installation were 118.1 and 114.2, respectively. In this study, it was also found that small value of C is used in the design of water pipe system. Therefore, excessively bigger size of pipe can be determined in the design of water pipe system. From the results of present study, optimum value of C can be used to avoid the oversized design of water pipe system.

Development of Waterworks Piping MHD Technology for USN Advancement in U-City/BIM (U-City/BIM USN 고도화를 위한 상수도배관용 자기유체발전 기술 개발)

  • Hwang, Jung-Rae;Lee, Hyun-Dong;Oh, Yoon-Seuk;Kwak, Pill-Jae;Kim, Gi-Eun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.4
    • /
    • pp.555-563
    • /
    • 2012
  • Due to the importance of energy-saving and CO2 reduction is being emphasized in the world, efforts to find a solution for the problems is increasing rapidly. In particular, the renewable energy is on understanding as a breakthrough for the protection of the environment and the economic development, so it is intensively fostered as future industries. Developed countries are already pursuing policy and technology development related with renewable energy. In this paper, we will develop MHD(Magneto Hydro Dynamics) technology to supply the commercial power that can is targeted at water pipe related with hydro power among renewable energy technologies. Kinetic energy of fluid flowing in the water pipe is converted into electric power. It allows stable power supply to the various sensors and devices on water pipe. We have performed several experiments to verify the application possibility of the developed technologies and present the result and a method of performance improvement of the technologies.

Bacterial Regrowth in Water Distribution Systems and Its Relationship to the Water Quality: Case Study of Two Distribution Systems in Korea

  • Yoon, Tae-Ho;Lee, Yoon-Jin
    • Journal of Microbiology and Biotechnology
    • /
    • v.14 no.2
    • /
    • pp.262-267
    • /
    • 2004
  • This study was done to observe the occurrence of heterotrophic bacteria in terms of free chlorine residuals in two different water distribution systems, which belongs to both K and Y water treatment plant of S city in Korea. The data analyzed in the distribution systems show that the free chlorine residuals decreased from 0.10 to 0.56 mg/l for K, and 0.51 to 0.78 mg/l for Y. The decay of free chlorine is clearly higher in both March and August than in January. The HPC in the distribution systems are ranged from 0 to 40 cfu/ml for K, 0 to 270 cfu/ml for Y, on $R_2$A medium. In particular, its level is relatively high at the consumer's ground storage tanks, taps, and the point-of-end area of Y. The predominant genera that were studied in the distribution systems were Acinetobacter, Sphingomonas (branch of Pseudomonas), Micrococcus, Bacillus, Staphylococcus. The diversity of heterotrophic bacteria increases in the end-point area. Most of them are either encapsulated cells or of Gram-positve cocci. In conclusion, the point-of-end area in distribution systems shows the longer flow distance from the water treatment plants, along with a greater diversity and a higher level of heterotrophic bacteria, due to the significant decay of free chlorine residuals.

Development of Guidelines for Physical Security Systems of Small-scale Water Supplies (소규모수도시설의 보안시설 설치지침 개발)

  • Kim, Youngil;Yi, Sangjin;Lee, Doojin;Lee, Wontae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.6
    • /
    • pp.723-730
    • /
    • 2013
  • Due to the event of hazardous chemical injection into a water storage tank in Hongseong, Chungcheongnam-do in 2012, the Korean Ministry of Environment has revised the enforcement rules of the Water Supply and Waterworks Installation Act to install surveillance equipments such as closed-circuit television(CCTV). However, the enforcement rules still do not provide concrete provision for installation of physical security equipments. Thus we studied vulnerability of small-scale water supplies in Korea and developed guidelines for the physical security system of the facilities. The guidelines include selection and recommendation of the physical security approaches and measures to detect, delay and response to the presence of an intruder in small-scale water supplies. The security features include protection utilities(e.g., fencing and fence topping), exterior intrusion detectors and alarms, locks and padlocks, surveillance utilities(e.g., CCTV), and others.

Development and Performance of Water Purifier with the Auto-Disinfected on a simple Drinking Water (간이상수도 자동소독 정수기의 개발 및 성능에 관한 연구)

  • Cho, Byeung-Rak;Lee, Bae-Bok;Choi, Myeung-Bu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.16 no.2
    • /
    • pp.41-46
    • /
    • 2013
  • On the purpose of helping the inhabitants living in farming, fishing villages, and islands for more safe and hygienic water from simple waterworks, experimental investigations were performed concerning the development of a water purifier with silver nanomaterial packed, having a function of the auto-disinfection. The results show as follows through such filteration and auto-disinfection processes. It is possible to get hygienic and safe water, for example, more than 95% of general bacteria, total coliforms, and fecal coliforms were removed. It is also possible to get good-quality water, for 49.4% of spent potassium permanganate and 85% and 63% of turbidity and conductivity were removed respectively. It is a very effective equipment, for 100% cost reduction of used chemicals was achieved by no-chemical disinfection process and THM was not generated.