• Title/Summary/Keyword: waterworks

Search Result 285, Processing Time 0.025 seconds

Field Application of Waterworks Automatic Meter Reading and Analysis of Household Water Use (상수도 원격검침시스템의 현장 적용성 평가 및 가정용수 사용량 분석)

  • Joo, Jin Chul;Ahn, Hosang;Ahn, Chang Hyuck;Ko, Kyung-Rok;Oh, Hyun Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.10
    • /
    • pp.656-663
    • /
    • 2012
  • After the construction of waterworks automatic meter reading with 15 mm diameter digital water mater with magnetoresistance sensor developed in this study at 96 households of apartment complexes located in Incheon-City B-Gu S-Dong, the feasibility of field application of waterworks automatic meter reading was evaluated. The field application of waterworks automatic meter reading was performed from July to December in 2011, and average reception rate was as low as 84.6% due to the instable wibro networks, the existence of communication blackout and temporary malfunction of router. After the extraction of 10 households with one to five residents out of 96 households by using stratified random sampling method and analysis of domestic water use, it was found that domestic water use was significant at August and showed a decreasing trend at September, followed by increase in domestic water use at November and decrease in domestic water use at December. This phenomenon should be attributed to weather factors (temperature, humidity, etc.), which significantly affected domestic water use. Similar trend in domestic water use in terms of weather factors was obtained in case of Liter per capita day of water use after the extraction of 30 households out of 96 households by using stratified random sampling method. After analysis of Liter per capita day for 96 households, single residents increases resulted in reduction of domestic water usage by about 14% of Liter per capita day. These results might be due to the fact that domestic water usage such as laundry, beverages, catering, cleaning, etc. should be required for even the household with one resident, whereas domestic water usage for those common utilization can be significantly saved for the household with more than one resident.

Characteristics of Water Quality Parameters of Han River Related to THMs Formation in Water Treatment Plants in Seoul (서울시 정수장의 THMs 생성과 관련된 한강 원수의 주요 수질 특성 조사)

  • Lee, Jin-Hyo;Lee, Ki-Seon;Hwang, Dong-Hyun;Lee, Man-Ho;Han, Sun-Hee;Park, Yong-Sang;Lee, Mok-Young;Lee, Jin-Sook;Koo, Ja-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.12
    • /
    • pp.886-892
    • /
    • 2011
  • In a study on THMs formation at the distribution facilities in Seoul water supply for past 3 years from 2007 to 2009, THMs production was increased from inlet to outlet during the process in water treatment plant. However, such increased THMs amount was very small compared to THMs production formed after pre-chlorination and post chlorination. Accordingly, this study is aimed to investigate the characteristics of water quality parameters of Han River related to THMs formation in 6 water treatment plants in Seoul. The results showed that THMs and other factors such as temperature (r = 0.539~0.846) and turbidity (r = 0.421~0.863) had positive correlation while THMs had negative correlation with pH (r = -0.613~-0.800) and algae (r = -0.582~-0.901). There is no correlation between THMs and $NH_3-N$. According to the factor analysis, generally metabolite and organic matter factor $X_1$ (pH, BOD, algae), and seasonal and natural factor $X_2$ (temperature, turbidity) played an important role in the formation of THMs. Multiple regression analysis for THMs formation showed significance of regression appeared in most water systems.

Effect of Wangsuk Stream on NOM and Chlorinated DBPFPs in Han River Water (왕숙천 유입에 따른 한강본류의 천연유기물질과 염소소독부산물 생성능 변화)

  • Park, Hyeon;Kim, Chang-Mo;Chang, Hyun-Seong;Kim, Hyun-Suk;Park, Chang-Min;Yu, Myong-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.10
    • /
    • pp.1031-1037
    • /
    • 2006
  • The main purposes of this study were to compare the characteristics of fractionated natural organic matters(NOM) from Han River water and Wangsuk(W) stream water, and to investigate the relationships between NOM and the formation of disinfection by products(DBPs). Three types of resin such as XAD-4, XAD-7HP and IRC-50 were used to isolate the water samples into three organic fractions. The DOC concentrations of raw waters were relatively low($1.5{\sim}3.3$ mg/L) at all seasons. The hydrophilic was the major constituent, contributing $44{\sim}63%$ of the total NOM and hydrophobic $21{\sim}33%$, transphilic $16{\sim}31%$, respectively. The formation of trihalomethans(THMs) was highly influenced by particulated NOM especially in the rainy season, whereas haloaceticacid forming potentials(HAAFPs) depended more on the hydrophilic fraction of dissolved NOM which is known to be difficult to be removed through conventional processes. The NOM of W stream was characterized as 15% hydrophobic, 9% transphilic, and 76% hydrophilic. In the fractionation of NOM using resins, $20{\sim}40%$ of the NOM in W tributary water could not be clearly isolated, whereas, 85% of the NOM in the raw water was recovered. Although the DOC concentration of tributary water was higher than the raw waters from the Han River, the DBPFPs was approximately 40% of the raw waters. In DBPFPs aspect, W stream has less effect than Han River water itself. Bromide in tributary waters discharged from waste water treatment plants has been found to shift the distribution of THMs and HANs to the more brominated DBPs.

Effect of Fractionated Organic Matter on Membrane Fouling (분류된 천연유기물질을 이용한 막 오염 특성 평가)

  • Lee, Byung-Gu;Son, Hee-Jong;Roh, Jae-Soon;Hwang, Young-Do;Jung, Chul-Woo;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.12
    • /
    • pp.1321-1326
    • /
    • 2005
  • As a results of this research, the Nakdong River consisted of 43% of hydrophobic fraction, 39% of hydrophilic fraction, and 18% of transphilic fraction. The hydrophobic fraction in this raw water was mostly fulvic acid. Fulvic acid comprised of 62% and the rest was humic acid(38%). There was more carboxylic acid functional roup(64%) than phenolic group(36%). HPI-N and HPI-C comprised of 17% and 22% in the hydrophilic portion, respectively. The results of the membrane fouling test using UF membrane according to NOM fractions. HPI-N caused more fouling than HPI-C. Humic acid caused more fouling than fulvic acid probably due to higher adsorption capacity. Since humic acid has higher adsorption capacity than fulvic acid, it would be more adsorbed onto the membrane pores. The carboxylic acid functional group caused more fouling than the phenolic group.

Distribution of Uranium in the Han River and Behavior through the Water Treatment Process (우라늄(Uranium)의 한강수계내 분포와 정수처리 공정별 거동 특성)

  • Jeong, Gwan-Jo;Kim, Dok-Chan;Park, Hyeon;Oh, Sea-Jong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.347-352
    • /
    • 2005
  • This research was focused on the distribution of Uranium-238 concentration in the Han River. Also, six water treatment plants in Seoul have been investigated to find out the behaviour and the removal capability of uranium. The uranium concentrations were ranged $0.02{\sim}0.54{\mu}g/L$ in the Han River. The relationship between conductivity and total dissolved solids shows that uranium concentration is positively related with conductivity and total dissolved solids. In addition, it has been founded that there was no relevance between uranium concentration and geological structure, because most of the sampling area are Banded Gneiss. The average uranium concentration in six water treatment plants was determined to $0.134\;{\mu}g/L$ in raw water, $0.050\;{\mu}g/L$ in coagulated water, $0.029\;{\mu}g/L$ in settled water, $0.020\;{\mu}g/L$ in filtered water, $0.019\;{\mu}g/L$ in finished water. After filtration in the treatment process, uranium concentration level was maintained lower than $0.029\;{\mu}g/L$. The average uranium removal efficiency compared to the raw water was 63% after coagulation, 15% after sedimentation, 8% after filtration and disinfection. The analysis shows that 78% of uranium in the raw water was removed during coagulation and sedimentation processes. However, 8% of that was removed through filtration and chlorination processes.

Removal Characteristics of Natural Organic Matters in Activated Carbon and Biofiltration Process (활성탄 공정과 생물여과 공정에서의 자연유기물질 제거특성)

  • Son, Hee-Jong;Choi, Keun-Joo;Kim, Sang-Goo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.2
    • /
    • pp.205-213
    • /
    • 2007
  • We have studied NOM(natural organic matters) adsorption and biodegradation on 3 kinds of activated carbon and a anthracite. Coal based activated carbon showed the highest DOC(dissolved organic carbon) adsorption capability and roconut(samchully), wood (pica) in the order among the 3 kinds of activated carbon(F400). The biomass amount and activity also showed on coal, wood and coconut based activated carbon in the order. Over 15 minutes EBCT(empty bed contact time) needed to achieve 10 to 17% average removal efficiency and $18\sim24%$ maximum removal efficiency of NOM biodegradation in biofilter using anthracite. Hydrophobic and below 10,000 dalton NOM was much easier to adsorb into the activated carbon than hydrophilic NOM, THMFP(trihalomethane formation potential) and BDOC (biodegradable dissolved organic carbon)$_{slow}$ were much easier than HAA5FP(haloacetic acid 5 formation potential) and $BDOC_{rapid}$ to adsorb into the activated carbon. Hydrophilic and below 1,000 dalton NOM was much easily biodegraded and HAA5FP and $BDOC_{rapid}$ was easier than THMFT and $BDOC_{slow}$ to biodegrade in the biofilter.

Variation of Pollutant Removal Efficiency and Backwashing Effect of BAC Basin in Advanced Water Treatment Processes (고도정수공정에서 오염물질 제거효율 변화특성과 BAC조의 역세척에 따른 영향)

  • Park, Soo-Yee;Lee, Sang-Bong;Sin, Sang-Min;Jun, Chang-Jea;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.1
    • /
    • pp.45-53
    • /
    • 2008
  • In this paper, the property of influent water and variations of removal efficiencies in each unit processes were studied based on the experiment data from the advanced water treatment plant in a city of Korea. The microbial species in the biological activated carbon(BAC) after backwashing of activated carbon filtration tank(ACFT) were also identified. The property and the removal efficiencies were evaluated by considering 8-9 items. The variations of 4 items were investigated from the influent and effluent of ACFT. SEM recording were conducted on BAC samples before and after backwashing. And the existence of attached microorganisms were identified through HPC(Heterotrophic Plate Counter) investigation. For the property of influent water, the concentrations of most items were maintained in the constant ranges, some items had seasonal properties. For the removal efficiencies, there were some items showing similar monthly-pattern and increasing with time, other items decreasing at the ozone contactor. Through these investigations, it was possible to distinguish the target items, which were removed by the advanced processes. The existence of microorganisms in ACFT could be predicted based on the variation curve of NH$_3$-N, and this fact were proved by SEM and HPC.

A Study on the Efficient Management Plan of Water Distribution Reservoirs Facility Using 3D Geospatial Information (3D 공간정보를 이용한 배수지시설물의 효율적인 관리방안에 관한 연구)

  • Jung, In Hun;Ro, Young Suk;Choi, Yun Soo;Woo, Sang Yoon;Kim, Chong Mun
    • Spatial Information Research
    • /
    • v.20 no.6
    • /
    • pp.109-118
    • /
    • 2012
  • Recent increasement of metropolitan infrastructure due to rapid expansion and development of urban areas which caused complexity and diversification of management system demands higher cost and effort to manage and maintain the facilities. The reason why it requires continuous and systematic management by national government is that the infrastructure facilities takes important role as it is directly related to public's living. Thus this study suggests an efficient management plan for increasement of work efficiency, cost reduction, and time saving by introducing 3D geospatial information system for water distribution reservoirs which is managed by the Office of Waterworks Seoul Metropolitan Government. This study evaluates and quantifies the range of work improvement using the 3D GIS technology through carrying out a survey targeting people in charge of the Office of Waterworks Seoul Metropolitan Government and other 8 offices. From the result of the research, applying the 3D-GIS improves by 90.32%, 93.55%, and 91.61% in the area of work efficiency, cost reduction, and time saving respectively. Consequently, using 3D GIS in future management of infrastructure could be used as a way of producing base data which supports administrative decision making through statistical and case analysis based on continuous data management. Also it would contribute to improving work efficiency by improving management system through preventing data omission.

Detection and Distribution of the Pathogenic Bioagent Aeromonas (Gamma-Proteobacteria) in Water Supplies of Seoul (서울시 상수계통에서 병원성균 Aeromonas (감마-프로테오박테리아) 분포연구)

  • Lee, Eun-Sook;Lee, Mok-Young;Han, Sun-Hee;Ka, Jong-Ok
    • Korean Journal of Microbiology
    • /
    • v.43 no.2
    • /
    • pp.106-110
    • /
    • 2007
  • The detection and distribution of Aeromonas in water supplies were investigated by using the USEPA Method 1605. Water samples were collected from the Han River, finished waters and tap waters supplied from Water Treatment Plants in Seoul monthly from July 2002 to December 2003. Aeromonas species in each water sample were quantified based on the development of yellow colonies on the surface of membrane filter using a selective medium (Ampicillin-Dextrin Agar with Vancomycin). The Quality Control (QC) for this study met the acceptance criteria of Method 1605. The concentrations of Aeromonas species in surface water samples ranged from $1.0{\times}10^{0}\;to\;9.8{\times}10^{3}\;CFU/ml$. Aeromonas species were found only in one tap water sample with concentration of 1 CFU/500 ml. No Aeromonas species were found in any finished water samples. Aeromonas species detected here were identified as A. salmonicida(51%), A. caviae(4.7%), A. schubertti(3.4%), A. sobria(3.8%), A. hydrophila(2.1%), and A. ichithiosmia(0.4%). A. salmonicida was the dominant species, which is of no significance to human health. Chlorine resistance of A. salmonicida was evaluated and as a result, 99.99% of A. salmonicida decreased after 30 seconds exposure at residual free chlorine 0.2 mg/L. These suggest that the waters supplied in Seoul may be safe against the pathogenic agent Aeromonas.

Interlaboratory Study for Cryptosporidium and Giardia Test Methods in Water (정수장 원생동물 분석방법의 국내 실험실간 교차시험 연구)

  • Chung, Hyenmi;Park, Sangjung;Kim, Daekyun;Park, Sanghee;Kim, Reeho;Lee, Sangho;Cho, Joorae;Lee, Kyeunghee;Park, Jonggeun;Lee, Mokyoung;Byun, Seungheon;Cho, Eunju;Rhim, Yeontaek
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.321-327
    • /
    • 2006
  • This interlaboratory study was designed to evaluate protozoan test methods in water and to predict the major causes of deviation of the methods. Each of four laboratories with previous experience of protozoa analysis in water participated, and met the initial performance criteria of EPA 1623 method provided. The protozoan analysis procedure consists of filtrations, concentration, immunomagnetic separation, dyeing (staining) and counting with observation. We tested three different filtration equipments: capsule filter for 10 L of surface water, and high volume (HV) capsule filter and membrane filter for 100 L of finished water. When the recovery of each step of the procedure was evaluated with EasySeed, the commercial stock of each 100 Cryptosporidium and Giardia, immunomagnetic separation and filtration step were the most crucial steps affecting the stability of the recovery, especially for Cryptosporidium. There was no significant difference of recovery among the filtration methods. Recovery of protozoa from source water were evaluated with spiked EasySeed as matrix tests. The recoveries of Giardia increased significantly in the matrix tests compared those in the deionized water. We also applied red stained mixture stocks of Cryptosporidium and Giardia called ColorSeed as internal standards of water sample tests. The recoveries of both EasySeed and ColorSeed in samples tested were within the range of the criteria, however, the Giardia recoveries using ColorSeed decreased significantly. Further optimization study with ColorSeed will be necessary, considering the convenience of using the internal standard without additional sample analysis. The significant factors of the recovery variation were identified as the differences of laboratories as well as water quality and type of the stock for spiking. The results of this study emphasize the importance of the quality assurance program for protozoan analysis lab in water.