• Title/Summary/Keyword: waterproof layer

Search Result 73, Processing Time 0.026 seconds

A study on the External Insulation and Waterproof Method of Rooftop (옥상부 외단열 및 외방수 공법 제안에 관한 기초연구)

  • Jang, Dae-Hee
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.137-138
    • /
    • 2019
  • To overcome the limitation in relation to thermal insulator's selection and installation method that is suitable for exterior insulation and waterproof construction methods, a production basis of thermal insulators of which manufacturing knowhow is held by companies was ensured and future-oriented construction methods to adopt new materials were applied. Performance verification was conducted through performance and mock-up tests of thermal transmittance on the cross sections where the flexible insulators were applied based on the improved prototype and performance data were obtained. To overcome the biggest drawbacks (walking feeling and damage etc.) in the exterior insulation and waterproof construction method, inserting a protective layer between thermal insulator and water-proof layer was proposed, and polypropylene corrugated cardboards.

  • PDF

Stress Analysis in Waterproof Layer on Steel Bridge Deck Pavement Using Finite Element Analysis (유한요소해석을 이용한 교면포장의 방수층에서의 응력해석)

  • Woo, Young-Jin;Lee, Hyun-Jong;Park, Hee-Mun;Choi, Ji-Young
    • International Journal of Highway Engineering
    • /
    • v.10 no.1
    • /
    • pp.11-18
    • /
    • 2008
  • The behavior of pavement and waterproofing layer on the steel bridge deck system under traffic loading was analyzed using a finite element method in this paper. In the finite element analysis, the othotropic steel bridge deck is represented by equivalent plate using solid element instead of shell element and the interface is assumed perfect bonding state. The effects of several parameters such as thickness of deck, Young's modulus of deck, thickness of pavement, different braking loading, and temperature on the stresses and strain in the interface are investigated for bridge deck pavement. The shear stress of waterproof layer increases with decrease of bridge deck thickness and stiffness. The change of shear stress is negligible when the bridge deck thictaess is greater than 150mm and stiffness is greater than $2{\times}10^{5}MPa$. As the pavement thickness and temperature decrease, the shear stress in the waterproof layer tends to be increased. The tensile strain at the bottom asphalt layer decreases as the temperature and thickness increase.

  • PDF

Waterproofing performance evaluation according to the number of layer for shield TBM segment hydrophilic rubber waterstop (쉴드 TBM 세그먼트 지수재의 배열수 변화에 따른 방수성능 평가)

  • Ham, Soo-Kwon;Jung, Hoon;Kim, Beom-Ju;Jeong, Kyeong-han;Lee, Seok-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.1
    • /
    • pp.47-58
    • /
    • 2020
  • The interest in the use of shield TBM (Tunnel Boring Machine) on the tunnel excavation has been increased rapidly in Korea. The shield TBM tunnel is generally designed as non-drainage tunnel. Consequently, if water leakage through the segment joints happens, big problems on the usage and stability of tunnel can be occurred. In this study, the variation of waterproof capacity of hydrophilic rubber waterstop by the construction error and excessive displacement of segment was studied. In particular, the waterproof capacity of each of single and double layer arrangements of hydrophilic rubber waterstop was examined to verify the efficiency of the double layer arrangement. The test results show that the single layer and double layer hydrophilic rubber waterstop showed the same waterproof performance. hydrophilic rubber waterstop has favorable on the offset, however unfavorable on the gap.

Tensile Bond Strength Westing When Changing Adhesion Method of Double-sided Waterproof Sheet Used on Surface Layer of Bridge-deck (교면용 양면 시트방수재 상부 포장층 재료에 따른 부착방법 변경시 인장접착강도 확인)

  • An, Ki-Won;Kim, Chun-Hag;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.217-218
    • /
    • 2019
  • In this study, to overcome the limitation of material application as the surface layer of bridge decks (asphalt concrete, concrete), a newly developed waterproof sheet is proposed to be usable for both asphalt concrete and concrete. Subsequent tensile bond strength was tested, and the test results showed that the tensile bond strengths were similar to depending on the type of the surface layer material for bridge decks, confirming the applicability of the proposed material.

  • PDF

A Study on the Injection Characters of The Back Side Grouting Method by a Model Test (모형실험을 통한 배면지수 그라우팅기법에 관한 연구)

  • Chun, Byung-Sik;Choi, Choon-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.2
    • /
    • pp.175-182
    • /
    • 2002
  • The cement injection technology on the purpose of ground reinforcement and cut-off has been used in construction sites until now. However, recently it is applied to prevent leakage of underground structure. In this study, applicability of the back side waterproof grouting method was verified through performing field model tests and reviewing case histories. From the results of this study, injection shape of the back side waterproof grouting method was appeared to be root type, and waterproof effect by injection of cement grout material was excellent because grout material infiltrated into boundary between wall of structure and back side ground to be waterproof layer. Components influencing infiltration of injection material are type of soil and degree of compaction. For effective injection, injection pressure has to vary gradually from high pressure to low pessure and small quantity of injection material has to be injected for long times. Also, spacing of injection hole must be designed considering condition of back side ground, injection area, W/C ratio, the number of injection and injection pattern properly.

A Trend on Quality Transformation of Waterproof Agent and Admixture of Cement for Concrete Surface Treatment (콘크리트 표면처리용 시멘트 액체방수제의 품질동향)

  • 최은수;김영근;박헌일;정순자
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.557-560
    • /
    • 2003
  • This study deals with the method of test for waterproof agent and admixture of cement, and especially, the effect on bond strength between waterproofing layer and mortar or concrete substrate in building construction. Quality of that has been managed according to it of construction standard manual, housing construction manual, 건, and Q until performance of that is specified by law as KS F 4923. Therefore this study focus on the quality and trend for a fatty system and PCM(Polymer Cement Mortar)

  • PDF

A Study on the Development and Estimation of Waterproof Outlet for Low Voltage (저압용 방수 콘센트의 개발 및 평가에 관한 연구)

  • Choi, Chung-Seog;Kim, Chang-Soung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.181-185
    • /
    • 2008
  • In this paper, we investigates accident actual conditions of electric outlet for low voltage that is used into interior and clear hazardous factor. Electric outlet for general can know that melting of socket-outlet and carbonization of support occur if a contaminant becomes burnout because is flowed in. Existent outlet consists of structure that special quality is good but inflow of a contaminant is easy when is dry. But, waterproof outlet passes silicon layer and have connected structure plug. As developed outlet covers whole surface and back side, interval was shut. Safety pin of developed outlet was established to operate to vertical direction. Therefore, we estimate that contribute on prevention of electrical disaster if use developed outlet to a restaurant, a laundry, a laboratory etc.

Improvement of Watertightness Evaluation Method in Waterproof Membrane (복합계 멤브레인 방수층의 수밀성 시험 평가방법 개선방안 연구)

  • Kim, Meong-Ji;Seon, Yun-Suk;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.50-51
    • /
    • 2018
  • Although the introduction of new materials and new construction methods and overseas materials has become more active due to the diversification of the construction market, the quality standards of waterproofing methods in Korea are insufficient. In particular, the quality control standard is applied to the KS F 2622:08 (Membrane Waterproofing layer performance test method), which is the existing standard, to prepare standards for quality control of waterproof materials, which is increased in Korea.

  • PDF

Water Vapour Transfer through Fabrics for Outdoor Activities (야외 운동복용 직물에서의 수분전달)

  • O, Ae Gyeong;Park, Jeong Wan
    • Textile Coloration and Finishing
    • /
    • v.15 no.3
    • /
    • pp.66-66
    • /
    • 2003
  • 야외 운동(outdoor activities)복에 사용되는 소재들은 외부로부터 신체를 안전하게 보호해 주어야 될 뿐 아니라 쾌적하게 유지시켜 주어야 한다. 의복착용시 쾌적감에 결정적인 영향을 미치는 인자는 몸의 열적 평형상태를 유지하기 위한 수단인 수분전달 특성이다. 본 연구는 여러 종류의 야외 운동복용 직물에서의 수분전달 현상을 조사하여 규명하므로써 이 직물들이 실제 의복생활에 응용될 의복계 (clothing system)를 형성하였을 때의 수분전달 현상을 설명하고자 하는 기초연구이다. 연구의 결과는 base layer용, mid layer용 직물들이 shell layer로 쓰이는 waterproof breathable 직물보다 수분 전달률이 높았으며, waterproof breathable 직물의 수분 전달률은 microfibre 직물, PTFE-laminated 직물 그리고 polyurethane coated 직물 순 이었다. 또한 polyurethane 직물에서는 back coated 직물이 face-coated 직물보다 수분 전달률이 높았다.

Water Vapour Transfer through Fabrics for Outdoor Activities (야외 운동복용 직물에서의 수분전달)

  • Oh, Ae-gyeong;Park, Jung-whan
    • Textile Coloration and Finishing
    • /
    • v.15 no.3
    • /
    • pp.192-196
    • /
    • 2003
  • 야외 운동(outdoor activities)복에 사용되는 소재들은 외부로부터 신체를 안전하게 보호해 주어야 될 뿐 아니라 쾌적하게 유지시켜 주어야 한다. 의복착용시 쾌적감에 결정적인 영향을 미치는 인자는 몸의 열적 평형상태를 유지하기 위한 수단인 수분전달 특성이다. 본 연구는 여러 종류의 야외 운동복용 직물에서의 수분전달 현상을 조사하여 규명하므로써 이 직물들이 실제 의복생활에 응용될 의복계(clothing system)를 형성하였을 때의 수분전달 현상을 설명하고자 하는 기초연구이다. 연구의 결과는 base layer용, mid layer용 직물들이 shell layer로 쓰이는 waterproof breathable 직물보다 수분 전달률이 높았으며, waterproof breathable 직물의 수분 전달률은 microfibre 직물, PTFE-laminated 직물 그리고 polyurethane coated 직물 순 이었다. 또한 polyurethane 직물에서는 back coated 직물이 face-coated 직물보다 수분 전달률이 높았다.