• 제목/요약/키워드: waterproof design

검색결과 88건 처리시간 0.02초

수온 모니터링 기능을 탑재한 심장마비 방지용 목욕 보조 시스템 (Development of a Bath Assistive System with Water Temperature Monitoring to Prevent Heart Attack)

  • 강소명;웨이췬
    • 한국멀티미디어학회논문지
    • /
    • 제22권2호
    • /
    • pp.242-249
    • /
    • 2019
  • Old people and patients with cardiovascular disease could die of a heart attack in the bath with heated water for a long time. Various researches have been studied to prevent these accidents from happening such as measuring the ECG signal when taking bath. However, these devices are hard to use and the higher price is not easily accepted by the public. In this paper, a low-cost and use-friendly, real time high precision water temperature monitoring device to prevent heart attack in the bath was developed. The device with waterproof design that lets the device can float on the surface of the water, and an accurate way to make water temperature measurement method was proposed by this paper that is immerging the sensor into water with 4cm depth to measure the temperature of underwater. The manufactured device was conducted to two experiments; one was to verify the basic functions of the device, and another one was for compare the proposed device with commercial products for monitoring the water temperature in the bathtub. As the experimental results shown, the proposed device has stable performance for the water temperature measurement and communicating with laptop in wireless.

Effect of Silane Coupling Treatment on the Joining and Sealing Performance between Polymer and Anodized Aluminum Alloy

  • Lee, Sung-Hyung;Yashiro, Hitoshi;Kure-Chu, Song-Zhu
    • 한국재료학회지
    • /
    • 제31권3호
    • /
    • pp.122-131
    • /
    • 2021
  • In the fabrication of joined materials between anodized aluminum alloy and polymer, the performance of the metal-polymer joining is greatly influenced by the chemical properties of the oxide film. In a previous study, the dependence of physical joining strength on the thickness, structure, pore formation, and surface roughness of films formed on aluminum alloys is investigated. In this study, we investigated the effect of silane coupling treatment on the joining strength and sealing performance between aluminum alloy and polymer. After a two-step anodization process with additional treatment by silane, the oxide film with chemically modified nanostructure is strongly bonded to the polymer through physical and chemical reactions. More specifically, after the two-step anodization with silane treatment, the oxide film has a three-dimensional (3D) nanostructure and the silane components are present in combination with hydroxyl groups up to a depth of 150 nm. Accordingly, the joining strength between the polymer and aluminum alloy increases from 29 to 35 MPa, and the helium leak performance increases from 10-2-10-4 to 10-8-10-9 Pa ㎥ s-1.

A modified shell-joint model for segmental tunnel dislocations under differential settlement

  • Jianguo Liu;Xiaohui Zhang;Yuyin Jin;Wenyuan Wang
    • Geomechanics and Engineering
    • /
    • 제35권4호
    • /
    • pp.411-424
    • /
    • 2023
  • Reasonable estimates of tunnel lining dislocations in the operation stage, especially under longitudinal differential settlement, are important for the design of waterproof gaskets. In this paper, a modified shell-joint model is proposed to calculate shield tunnel dislocations under longitudinal differential settlement, with the ability to consider the nonlinear shear stiffness of the joint. In the case of shell elements in the model, an elastoplastic damage constitutive model was adopted to describe the nonlinear stress-strain relationship of concrete. After verifying its applicability and correctness against a full-scale tunnel test and a joint shear test, the proposed model was used to analyze the dislocation behaviors of a shield tunnel in Shanghai Metro Line 2 under longitudinal differential settlement. Based on the results, when the tunnel structure is solely subjected to water-earth load, circumferential and longitudinal joint dislocations are all less than 0.1 mm. When the tunnel suffers longitudinal differential settlement and the curvature radius of the differential settlement is less than 300 m, although maximum longitudinal joint dislocation is still less than 0.1 mm, the maximum circumferential joint dislocation is approximately 10.3 mm, which leads to leakage and damage of the tunnel structure. However, with concavo-convex tenons applied to circumferential joints, the maximum dislocation value reduces to 4.5 mm.

공동주택 지하공간 누수 예방 기술 정책 수립을 위한 소비자 인식 분석 연구 (Consumer Awareness Analysis of Residential Building Underground Structure Leakage Prevention Measurements)

  • 한윤정;오규환;김수련;김병일;오상근
    • 한국건설순환자원학회논문집
    • /
    • 제4권4호
    • /
    • pp.379-387
    • /
    • 2016
  • 본 연구에서는 지하부위의 누수 예방 기술 정책 수립을 위한 방수 성능 분석 연구에 대하여 설문조사를 실시하고 이를 분석하였다. 설문 분석 결과, 현재 공동주택 지하공간에 대한 누수는 심각하며, 응답자 대부분도 이를 심각하게 인식하고 있다. 환경을 고려하지 않은 누수설계 및 누수예방 설계의 부재, 환경에 적합하지 않은 시공 시스템의 활용이 누수문제의 주요 원인이라 판단되었으며, 이를 개선하기 위하여 지하부위 외방수공법의 도입을 의무화하고, 설계시 공동주택 지하부위에 적용할 수 있는 표준 방수 기술 및 공법을 수립해야 될 것이며, 지하 시공환경을 고려한 방수 시공방법의 개발의 필요성이 강조되었다. 따라서 상기의 상황을 미루어 볼 때 법-제도에 의해 명시된 방수설계, 재료 및 공법, 유지관리 등을 방수시공의 전반적인 상황 컨트롤할 수 있는 가이드라인의 제시는 필수요소로 부각되었다.

일체형 방사선 피폭 방호 소방관 인명구조 경보기의 임베디드 보드 개발 (Development of Embedded Board for Integrated Radiation Exposure Protection Fireman's Life-saving Alarm)

  • 이영지;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.1461-1464
    • /
    • 2019
  • 본 논문에서는 위치추적과 방사선 측정이 가능한 일체형 방사선 피폭 방호 소방관 인명구조 경보기를 위한 임베디드 보드 개발을 제안한다. 제안하는 방사선 피폭 방호 소방관 인명구조 경보기의 임베디드 보드는 신호 처리부, 통신부, 전원부, 메인 제어부 등으로 구성된다. 신호 처리부에서는 차폐설계, 노이즈 저감 기술 및 전자파 차감 기술 등을 적용한다. 통신부에서는 WiFi 방식을 사용하여 통신하도록 설계한다. 메인 제어부에서는 전력 소모를 최소한으로 줄이고 작고 밀도가 높으면서도 낮은 발열성을 통하여 높은 고성능 시스템을 구성한다. 일체형 방사선 피폭 방호 소방관 인명구조 경보기를 위한 임베디드 보드는 재난 및 화재현장 등 열악한 환경에 노출되어 운영하는 장비이므로 방수와 내열성을 고려한 외형도 설계 및 제작을 한다. 제안된 일체형 방사선 피폭 방호 소방관 인명구조 경보기를 위한 임베디드 보드의 효율을 판단하기 위하여 공인시험기관에서 실험하였다. 방수 등급은 소방관용 장비의 특성 상 재해 현장에서 물에 의한 침수 시에도 안정적인 성능을 유지할 수 있는 IP67 등급을 달성하였다, 동작 온도는 재해현장에서의 폭넓은 환경변화에 대응할 수 있는 -10℃~50℃의 범위에서 측정이 되었다. 배터리 수명은 붕괴사고 등의 비상 재난 상황에 대처할 수 있는 1회 충전 후 144시간 사용 가능함이 측정되었다. PCB를 포함한 최대 통신 거리는 재난 상황 시 지휘통제 차량과의 직선거리에서 기존의 50m보다 넓은 범위인 54.2m에서 작동하는 것이 측정되었다. 따라서 일체형 방사선 피폭 방호 소방관 인명구조 경보기를 위한 임베디드 보드의 그 효용성이 입증되었다.

폴리프로필렌 섬유 보강 EVA 콘크리트의 압축강도 및 내구성 (The Compressive Strength and Durability Properties of Polypropylene Fiber Reinforced EVA Concrete)

  • 남기성;성찬용
    • 한국농공학회논문집
    • /
    • 제57권4호
    • /
    • pp.11-19
    • /
    • 2015
  • The important properties of EVA (ethylene vinyl acetate) redispersible polymer was waterproof, densification of internal pore space of concrete and ball bearing and micro filler. Also, the significant role of polypropylene(PP) fiber was crack control and blockade of movement for deterioration factors. The most studies for EVA were limited in the field of mortar and PP fiber reinforced concrete had been studied in the state of being restricted unit water content, rich mix and mixing much of the fiber without considering construction site. Therefore, the control mix design were applied in ready mixed concrete using 10 % fly ash of total cement weight used in batch plant. On the basis of control mix design, EVA contents ranging from 0 % to 10 % of total cement weight and PP fiber contents ranging from 0 % to 0.5 % of EVA concrete volume were used in the mix designs. The results showed the maximum compressive strength value was measured at EVA 5.0 % and PP fiber 0.1 %, the minimum water absorption ratio was at EVA 10 % and PP fiber 0 %, the durability factor for freezing and thawing resistance was at EVA 5.0 % and PP fiber 0.3 % and the minimum weight reduction ratio of resistance to sulfuric acid attack was at EVA 10 % and PP fiber 0.5 % after curing age 42days. Meanwhile, From these results, PP fiber reinforced EVA concrete would be very benefit, if each optimal mix types were used in hydraulic structures, underground utilities and agricultural structures.

장애인 맞춤형 주택 계획 관점에서 본 농촌지역 지체장애인 주거특성 연구 (Characteristics of Housing Condition for Physically Challenged Persons in Rural Area from the Viewpoint of Planning Customized Housing for the Disabled)

  • 이연숙;박지영;이동주
    • 한국실내디자인학회논문집
    • /
    • 제24권6호
    • /
    • pp.154-162
    • /
    • 2015
  • As there is no case study with current status, measurements or description on the state of actual site of rural area only, the delivery of actual conditions about such an area is significantly limited. The purpose of this study is to pinpoint issues with housing conditions of low-income family with disabled members in the rural area. For such a purpose, 25 households of disabled people have been visited for interview, on-site research and survey, of which results are summed up in this paper as following: First, average monthly income of such family turned out to be KRW 480,000, most of which is from the government subsidy. High ratio of such families has resided in a house with average size of approximately 56m2 for about 24 years. Secondly the most needed maintenance work with top priority was for the toilet, and many of the interviewees expressed their discomfort about small size of their bathrooms and inconvenient facilities therein. Thirdly, most of such houses had too high thresholds that posed danger and inconvenience. Such thresholds had average height of 13cm, which can be considered as completely inconsiderate of disabled users. Fourth issue was that these people needed safety handle that will enable them to stand up or to be in the standing posture in the living room and bedroom where they spend most of their time. Fifthly, they wanted finishing materials with waterproof functionality as well as replacement of finishing materials and wallpaper which were too old and caused hygiene issues. As these issues represent, current housing for disabled people in the rural area turned out to be poor and risky space rather than the place where difficulty of individual situation can be resolved or their disability can be complemented. Thus it can be determined that now is the time to arrange the solutions for such housing difficulties and to establish customized housing plan to ensure safety and convenience.

지하 구조물 외벽에 적용되는 방수재료의 구조체 거동 및 진동 대응 성능 설계 제안 연구 (A Study on the Seismic Performance Design of Waterproofing Materials Applied Single-side Walls on Underground Structures)

  • 김수연;김명지;오상근
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권1호
    • /
    • pp.43-50
    • /
    • 2020
  • 본 연구에서는 건설 구조물에 사용되는 건설 자재 중 콘크리트 구조체에 전면 부착 시공되어 건축물의 내외부로부터 스며들거나 넘쳐흐르는 물을 막을 수 있는 차단마감재인 방수재료에 있어 가속 환경 조건 속의 지하 외벽에서의 방수 성능 설계의 일환으로 내진 성능 설계가능성을 제안하고 그 품질검증 시험방법에 대해 검토하였다. 국내외 건설자재 내진설계 현황을 살펴보았을 때, 국내의 경우 아직까지 현행법상 건축 과정에서의 내진설계 규제는 있지만 자재에 대한 규제는 없어 내진용 제품군이 드물고 대부분 시공법에 의존하고 있는 상황이다. 국외의 경우 일본, 캐나다, 독일과 같이 비구조재에 내진성능을 부여한 다양한 건축자재가 개발되고 있음을 확일 할 수 있었고, 이러한 내진설계 개념은 앞장에서 살펴본 바와 같이, 지하 콘크리트 구조체에 전면접착 혹은 부분 부착되어 시공되는 선행 외방수재료에 있어 지진에 대한 보완 대응력을 가질 수 있다면 내진 설계된 구조체와 함께 누수 예방 및 방지 기술로서 그 적용성을 기대할 수 있을 것으로 판단된다.

터널형 탄약고의 격실 설계 방법에 대한 연구 (Study on Design Method of Tunnel-type Ammunition Storage Chamber)

  • 박상우;백장운;박영준
    • 한국건축시공학회지
    • /
    • 제20권3호
    • /
    • pp.279-287
    • /
    • 2020
  • 최근 지하형 탄약고에 대한 수요가 발생하고 사업이 구체화되고 있는 상황에서 지하형 탄약고에 대한 설계 방법의 부재가 상당한 걸림돌이 되고 있다. 본 연구에서 분석한 바와 같이 군 작전적 측면과 안전거리 기준 등의 안전 문제로 인해 민간에서 사용하는 일반적인 터널 설계 기준이나 지하형 탄약고에 대한 기존 연구결과들을 통해서는 제대로 된 지하형 탄약고를 구축할 수 없다. 따라서 실무자들이 지속적으로 순환되는 우리나라 군 및 관 특성상 표준화된 설계방법이 존재하지 않을 경우 지하형 탄약고의 설치는 상당히 지연될 수 밖에 없을 것이다. 이에 본 연구에서는 격실 설계, 격실 배치, 터널 및 출입구 설계, 공조설비 설계방법에 대해 고려해야할 사항들을 분석하고 전체적인 설계 프로세스를 정립하였다. 이를 토대로 설계 예시를 제공하였으며, 관련 전문가가 아니더라도 단계별로 설계를 따라 할 수 있도록 하였다. 지하형 탄약고는 세계적으로 시공사례가 많지 않다. 하지만 민·군 상생에 대한 국가 정책과 시장 추세를 비추어볼 때 지하형 탄약고에 대한 수요는 지속적으로 증가할 것으로 전망된다. 따라서 본 연구를 시작으로 지하형 탄약고에 대한 연구가 활성화되어 향후 대한민국이 기술 수출 등을 통해 세계 시장을 좌우할 수 있게 되기를 기대한다.

소방차 펌프의 방수성능 기준 재정립을 위한 실증적 연구 (An Empirical Study on the Standard Re-establishment of Water Discharge Performance for the Fire Engine Pump)

  • 민세홍;권용준
    • 한국화재소방학회논문지
    • /
    • 제26권5호
    • /
    • pp.85-91
    • /
    • 2012
  • 소방차에 설치되는 소방펌프에 대한 방수성능 기준이 현장에서 운용하고 있는 실태와 상이한 부분이 있고, 기준이 명확하게 규정되어 있지 않아 소방공무원이 화재현장에서 소방펌프의 사용시간, 최대사용압력, 사용 호스 직경 등 사용 실태를 분석하고, 그 결과를 토대로 소방펌프에 대한 압력별, 호스 직경별 수량별로 다양하게 성능시험을 실시하였다. 현장조사 결과, 소방자동차용 소방펌프의 성능에 관한 인정기준에서 규정하고 있는 규격방수압력(0.85MPa)과 고압방수압력(1.4 MPa)보다 현장에서는 더 높은 압력을 사용하고 있는 것으로 조사되었다. 또한, 펌프의 성능시험 결과는 방수량 및 방수압력 등이 호스의 직경, 관창에 따라 현재 규정하고 있는 인정기준과 매우 상이하게 측정되었으며, 본 연구 결과로 새로운 규격을 제안한다.