• Title/Summary/Keyword: waterline

Search Result 75, Processing Time 0.025 seconds

Estimation of morphological change using waterline method in the Ganghwado tidal flats

  • Lee, Yoon-Kyung;Ryu, Joo-Hyung;Eom, Jin-Ah;Jo, Min-Jeong
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.22-24
    • /
    • 2007
  • Waterline extraction is the one of widely used methods for studying changes in tidal flat environment and coastlines using multi-temporal optical images such as Landsat TM and Landsat ETM+. High dynamics of tidal currents and land reclamation which accelerate sedimentation and/or erosion cause waterline change in tidal flats. The amount of sediment deposited or eroded can be evaluated by precisely estimating waterline changes in tidal flats. The objective of this study is to detect the change of waterlines during 17 years and analyze the trends of erosion and sedimentation in the study areas. The Ganghwado tidal flat on the west coast of the Korean Peninsula was selected. The study area is famous for high dynamics of tidal currents and vast tidal flats. Land reclamation which has been carried out on a large scale is also considered as one of elements that have accelerated the environmental changes in this tidal flat. In this study, we acquired 26 waterlines from Landsat TM and Landsat ETM+ images. We extracted the waterline from each satellite image to generate a digital elevation map (DEM) which was used for reference and to compare with the other waterline which was extracted from DEM having a same tide. The result of comparison well depicted the areas of dominant sedimentation and erosion, and general trends of sedimentation and erosion according to sub-regions are also revealed during the investigation time. Results showed that erosion during a decade was dominant at the west of the Southern Ganghwado tidal flat, while sedimentation was dominant at the wide channel between the Southern Ganghwado tidal flat and the Yeongjongdo tidal flat. This area has been commonly affected by high currents and sedimentation energy. Although we were not able to verify the accuracy of the waterline changes, this result clearly showed the waterline change and therefore, the waterline extraction method used in this study has proven as an effective tool for long term tidal change estimation.

  • PDF

Awareness and practice of dental unit waterline management in dental hygienist (치과위생사의 치과 유니트 수관관리에 대한 인식과 실천도)

  • Lee, Seong-Sook;Kim, Dong-Ae;Song, Sun-Young;Kim, Mi-Yeon;Shim, Ha-Na
    • Journal of Korean society of Dental Hygiene
    • /
    • v.16 no.4
    • /
    • pp.507-516
    • /
    • 2016
  • Objectives: The purpose of the study is to investigate the awareness and practice of dental unit waterline management in dental hygienist. Methods: A self-reported questionnaire was completed by 377 dental hygienists in Seoul and Gyeonggido from March 2 to April 30, 2015. The data were collected by direct visit and informed consent was received after explanation of the study. The questionnaire consisted of general characteristics of the subjects, awareness of dental waterline, practice of dental waterline, and implementation of dental waterline disinfection. Data were analyzed using SPSS 12.0 program. Results: There was a significant correlation between the dental unit waterline disinfection and the appropriateness of the water used for dental treatment(p<0.01, p<0.001). The handpiece was the most commonly used device before treatment and the majority of the subjects answered that they didn't take water out of ultrasonic scaler and air-water syringe on a daily basis. Conclusions: The majority of the dental hygienists did not know the right understanding and proper practice of dental unit waterline management. To reduce the dental device contamination, the continuing education of waterline management should be done for the dental hygienists.

Intertidal DEM generation using waterline extracted and echo sounding (해안선 추출과 음향측심 자료를 이용한 조간대 Digital Elevation Map 제작)

  • Lee Yoon-Kyung;Ryu Joo-Hyung;Kim Chang-Hwan;Park Chan-Hong;Won Joong-Sun;Yoo Hong-Rhyong
    • Proceedings of the KSRS Conference
    • /
    • 2006.03a
    • /
    • pp.79-82
    • /
    • 2006
  • 조간대 지형의 발달과 변화에 대한 이해는 물순환 모델, 양식장 관리, 전자해도의 갱신, 연안개발 계획수립, 항로의 효율적 관리, 선박 안전항해, 상륙 작전 등에 있어서 매우 중요하다. 기존의 조간대 DEM 을 만드는 방법 중 위성영상을 이용한 waterline 방법과 선박을 이용한 음향측심(echo sounding) 방법이 있다. 이 연구의 목적은 위성 원격탐사 자료와 음향측심기 자료를 함께 사용하여 각각의 방법의 단점을 보완함으로서 조간대 DEM 의 정밀도를 향상시키는 것이다. 천수만 황도 조간대에 대해 음향측심에 의해 얻어진 자료를 관측소 조위와 단위를 일치시킨 후 광학위성으로부터 추출된 waterline 자료와 합성하여 DEM 을 제작하였다. 합성된 DEM 과 기존의 waterline 방법과 음향측심법으로 제작된 DEM 과 비교해 본 결과, 합성된 DEM 은 음향측심 자료에 의해 정밀도가 많이 향상되었으며 waterline 방법에 의해 지역적 특성이 잘 표현되었다. 따라서 개발된 방법은 음향측심 방법에 의해 만들어졌던 기존 해도의 정밀도를 업그레이드 하는데 활용될 수 있을 것으로 기대된다.

  • PDF

Corrosion Loss of the Shell Plates of the General Cargo Vessels and the Lumber Carriers According to the Age (일반화물선과 원목운반선의 선각외판 부식도의 선령별 변화)

  • 박중희
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.17 no.1
    • /
    • pp.13-18
    • /
    • 1981
  • Corrosion loss of the shell plates of the steel vessels are measured and analyzed on the thirty cargo vessels and fifteen lumber carriers of which nationality belong to Korea. Thickness of the shell plates were determined at the every observed points set along the fore and aft line and perpendicular to it, by use of the ultrasonic thickness meter. Difference of the thickness between the original and the determined shell plates are given as the corrosion loss at the present age. The results obtained are summarized as follows: 1. On the cargo vessels, (1) The total mean of the corrosion loss is greatest at the light waterline, in every age class of the vessels. (2) The total mean of the corrosion loss on the fore and aft line shows little difference, even though it is slightly greater at the fore part, in every age class of the vessels. (3) Corrosion loss along the perpendicular line grows greater in the order of freeboard, load waterline, upper bilge line and light waterline, within the 16 of the age of the observed vessels. Its order varies to freeboard, upper bilge line, load waterline and light waterline in the age of 35. Corrosion loss at the light waterline and load waterline, in the age of 35, shows 3 times of it at the freeboard, and it at the upper bildge line shows twice of it at the freeboard. The fact significates the corrosion grows rapidly around the waterline. 2. On the lumber carriers, (1) The total mean of the corrosion loss is greatest at the upper bilge line, in the every age class of the vessels. (2) Total mean of the corrosion loss on the fore and aft line shows little difference, even though it is slightly greater at the fore part, in every age class of the vessels. (3) Corrosion loss along the perpendicular line is least at the freeboard and greatest at the upper bilge line, and its value at the upper bilge line shows twice of it at the freeboard. 3. The total mean of the corrosion loss of the lumber carriers shows almost twice of the cargo vessels.

  • PDF

Comparative study on the resistance performance of an icebreaking cargo vessel according to the variation of waterline angles in pack ice conditions

  • Kim, Moon-Chan;Lee, Won-Joon;Shin, Yong-Jin
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.4
    • /
    • pp.876-893
    • /
    • 2014
  • The resistance performance of an icebreaking cargo vessel according to the variation of waterline angles is investigated numerically and experimentally. A recently developed Finite Element (FE) model is used in our analysis. A resistance test with synthetic ice is performed in the towing tank at Pusan National University (PNU) to compare and validate the computed results. We demonstrate good agreement between the experimental and numerical results. Shipice interaction loads are numerically calculated based on the Fluid Structure Interaction (FSI) method in the commercial FE package LS-DYNA. Test results from model testing with synthetic ice at the PNU towing tank are used to compare and validate the numerical simulations. For each waterline angle, numerical and experimental comparisons were made for three concentrations (90%, 80%, and 60%) of pack ice. Ice was modeled as a rigid body, but the ice density was the same as that used in the experiments. A comparative study according to the variation of stem angles is expected to be conducted in the near future.

Study on Resistance Performance of Icebreaking Cargo Vessel According to Variation of Thickness and Waterline Angle by Using Synthetic Ice (합성얼음을 이용한 얼음의 두께와 수선면각 변화에 따른 쇄빙상선 저항특성 연구)

  • Shin, Byung-Chul;Kim, Moon-Chan;Lee, Seung-Ho;Lee, Seung-Ki
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.2
    • /
    • pp.134-140
    • /
    • 2011
  • The present paper deals with characteristics of resistance performance according to the variation of synthetic ice thickness and hull form. The resistance test has been conducted with pack ice condition in Pusan National University towing tank. Waterline angle has been chosen as a main parameter for the variation of hull form characteristics, which is the most important factor especially in icebreaking cargo vessel. The serial comparisons of resistance test have been done with the variation of hull form parameter as well as with the different thickness of synthetic ice. The different trend of resistance performances with increasing of waterline angle has been shown at each synthetic ice thickness. The present test results is expected to be confirmed by comparing the test results in ice tank in the near future.

Spectral Characteristics of Shallow Turbid Water near the Shoreline on Inter-tidal Flat

  • Lee, Kyu-Sung;Kim, Tae-Hoon;Yun, Yeo-Sang;Shin, Sang-Min
    • Korean Journal of Remote Sensing
    • /
    • v.17 no.2
    • /
    • pp.131-139
    • /
    • 2001
  • Extraction of waterline in tidal flat has been one of the main concerns in the remote sensing of coastal region. This study aimed to define the spectral characteristics of turbid water near the shoreline and to find the appropriate spectrum to delineate the waterline at the inter-tidal flat in the western coast of Korean Peninsula. Spectral reflectance curves were obtained by the field measurements under the diverse condition of water depth and turbidity at the study area in Kyong-gi Bay. Spectroscopy measurements showed that reflectances of the exposed mudflat, shallow turbid water, and normal coastal water were significantly different by wavelength. Shallow water near the waterline showed diverse conditions of turbidity. Spectral reflectance tends to increase as turbidity increases, particularly at the visible and near infrared spectrum. At the middle infrared wavelength, tidal water showed very little reflectance regardless of the turbidity and water depth and was easily disting from the exposed tidal flat. The exact waterline between exposed tidal flat and seawater should be extracted from the image data obtained at the middle infrared wavelength.

On the Corrosion Protection Characteristics of Port Steel Structures Corroded Naturally for a Long Period of Time (장기간 자연 부식된 항만부두 강구조물의 방식특성 연구)

  • Kim, K.J.;Choi, Y.S.
    • Journal of Korean Port Research
    • /
    • v.12 no.1
    • /
    • pp.145-154
    • /
    • 1998
  • Protection characteristics of the corroded steel pile which was served as a pier structure over 8 years in seawater have been examined in terms of corrosion potential, electrochemical impedance spectroscopy(EIS) and anodic/cathodic polarization curves. The steel structure was sectioned into two parts, waterline(splash zone, just above the seawater surface) and in-water(underwater), and protection characteristics for the two parts were investigated with the application of cathodic protection(CP) by sacrificial anodes using Zn and Al alloys. The main results obtained were as follows; (1) The corrosion potential of waterline zone was higher than that of in-water, which implied that the corrosion of waterline was more severe than that of in-water, (2) As a result of EIS examination, the transition period from the apparent CP to the substantial CP took about twenty to thirty days according to the corrosion condition.

  • PDF

Intertidal DEM Generation Using Waterline Extracted from Remotely Sensed Data (원격탐사 자료로부터 해안선 추출에 의한 조간대 DEM 생성)

  • 류주형;조원진;원중선;이인태;전승수
    • Korean Journal of Remote Sensing
    • /
    • v.16 no.3
    • /
    • pp.221-233
    • /
    • 2000
  • An intertidal topography is continuously changed due to morphodynamics processes. Detection and measurement of topographic change for a tidal flat is important to make an integrated coastal area management plan as well as to carry out sedimentologic study. The objective of this study is to generate intertidal DEM using leveling data and waterlines extracted from optical and microwave remotely sensed data in a relatively short period. Waterline is defined as the border line between exposed tidal flat and water body. The contour of the terrain height in tidal flat is equivalent to the waterline. One can utilize satellite images to generate intertidal DEM over large areas. Extraction of the waterline in a SAR image is a difficult task to perform partly because of the presence of speckle and partly because of similarity between the signal returned from the sea surface and that from the exposed tidal flat surface or land. Waterlines in SAR intensity and coherence map can effectively be extracted with MSP-RoA edge detector. From multiple images obtained over a range of tide elevation, it is possible to build up a set of heighted waterline within intertidal zone, and then a gridded DEM can be interpolated. We have tested the proposed method over the Gomso Bay, and succeeded in generating intertidal DEM with relatively high accuracy.

A Convergence Study on Waterline Management of Unit Chair in Dental Hygiene Laboratory (교내 실습실의 유니트체어의 수관관리에 관한 융합연구)

  • Choi, Jung-OK
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.10
    • /
    • pp.27-31
    • /
    • 2019
  • The purpose of this study is to gather biofilm of unit chair waterline in the laboratory, to analyze microorganisms, to apply the existing draw-off method and the method of using disinfectant, and to compare the change of the number of microorganisms. The water was provided by the waterline of the unitchair, and the gathered samples were cultured with the use of R2A agar plate. Bacterial species separated through the identification of microorganisms were analyzed. To identify the decrease of microorganism for draw-off, samples were gathered in the intervals of 30 seconds, 60 seconds and 120 seconds, and to identify the effect of disinfectant, samples after disinfection were gathered. The quantitative comparison of microorganisms through the gathered samples was done by SPSS program. The number of identified bacteria are 8 species, most of which are gram-negative bacterium, and Sphingomonas type. The rapid decrease of the number of microorganism through draw-off for 60 seconds was confirmed, and microorganisms after disinfection weren't detected right away. Based on the method and result of this study, the water pipe of unit chair, which can be neglected easily, can be managed, so cross infection can be prevented, and systemic management can be possible.