• Title/Summary/Keyword: water-quality sensor

Search Result 177, Processing Time 0.025 seconds

Development of Surface Acoustic Wave Sensor for Viscosity Measurement of Low Viscose Liquid Using Love Wave (Love파를 이용한 저점성 유체 점도 측정용 표면 탄성파 센서 개발)

  • Lee, Sang-Dae;Kim, Ki-Bok;Lee, Dae-Su
    • Journal of Biosystems Engineering
    • /
    • v.33 no.4
    • /
    • pp.282-287
    • /
    • 2008
  • Love wave is one of the shear horizontal waves and it can propagate between two layers in liquid without energy loss. The SAW (surface acoustic wave) sensor using Love wave is very useful for real time measurement of the viscosity of liquid with high sensitivity. In this study, the 77 MHz and 155 MHz Love wave SAW sensors were fabricated and use to measure the viscosity of low viscous liquid. To generate the surface acoustic wave, the inter-digital transducers were fabricated on the quartz crystal wafer. In order to obtain the optimal thickness of the coating film (novolac photoresist) generating the Love wave on the surface of SAW device, theoretical calculation was performed. The performances of fabricated Love wave SAW sensors were tested. As test liquid, pure water and glycerol solutions having different concentrations were used. Since the determination coefficients of the regression equations for measuring the viscosity of liquid are greater than 0.98, the developed Love wave SAW sensors in this study will be very useful for precise measurement of viscosity of liquid.

Development of CMOS Image Monitoring System for Measurement of Biosensor Activity using Genetic Algorithm (유전자 알고리즘을 이용한 바이오센서 활동량 측정 CMOS 이미지 센서 모니터링 시스템 개발)

  • Park, Se-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.5
    • /
    • pp.930-936
    • /
    • 2008
  • CMOS image monitoring system for optimal measuring the activity of biosensor is developed using genetic algorithm. Most of living organism in water as water flea, fish, etc are frequently used as biological sensor for monitoring the water quality. It is very difficult to measure the activity of biosensor by image sensor because the value of measurement is varied with gathering method of biosensor images. The suggested monitoring system can optimally measures the activity of biosensor by genetic algorithm. The system is implemented with FPGA into the small hardware which is excellent in terms of the price and performance.

Applicability of unmanned aerial vehicle for chlorophyll-a map in river (하천녹조지도 작성을 위한 무인항공기 활용 가능성에 관한 연구)

  • Kim, Eunju;Nam, Sookhyun;Koo, Jae-Wuk;Lee, Saromi;Ahn, Changhyuk;Park, Jerhoh;Park, Jungil;Hwang, Tae-Mun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.3
    • /
    • pp.197-204
    • /
    • 2017
  • This study was carried out to apply the UAV(Unmanned Aerial Vehicle) coupled with Multispectral sensor for the algae bloom monitoring in river. The study acquired remote sensing data using UAV on the midstream area of Gum River, one of four major rivers in South Korea. Normalized difference vegetation index (NDVI) is used for monitoring algae change. This study conducted water sampling and analysis in the field for correlating with NDVI values. Among the samples analyzed, the chlorophyll concentration exhibited strong and significant linear relationships with NDVI, and thus NDVI was chosen for algae bloom index to identify emergence aspect of phytoplankton in river. Aerial remote sensing technology can provide more accurate, flexible, cheaper, and faster monitoring methods of detecting and predicting eutrophication and therefore cyanobacteria bloom in water reservoirs compared to currently used technology. As a result, there was high level of correlation in chlorophyll-a and NDVI. It is expected that when this remote water quality and pollution monitoring technology is applied in the field, it would be able to improve capabilities to deal with the river water quality and pollution at the early stage.

TiO2 Photocatalytic Reaction on Glass Fiber for Total Organic Carbon Analysis (총유기탄소 분석을 위한 유리섬유를 이용한 이산화티타늄 광촉매 반응)

  • Park, Buem Keun;Lee, Young-Jin;Shin, Jeong Hee;Paik, Jong-Hoo
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.102-106
    • /
    • 2022
  • Currently, the demand for real-time monitoring of water quality has increased dramatically. Total organic carbon (TOC) analysis is a suitable method for real-time analysis compared with conventional biochemical oxygen demand (BOD) and chemical oxygen demand (COD) methods in terms of analysis time. However, this method is expensive because of the complicated internal processes involved. The photocatalytic titanium dioxide (TiO2)-based TOC method is simpler as it omits more than three preprocessing steps. This is because it reacts only with organic carbon (OC) without extra processes. We optimized the rate between the TiO2 photocatalyst and binder solution and the TiO2 concentration. The efficiency was investigated under 365 nm UV exposure onto a TiO2 coated substrate. The optimized conditions were sufficient to apply a real-time monitoring system for water quality with a short reaction time (within 10 min). We expect that it can be applied in a wide range of water quality monitoring industries.

Software Design of Packet Analyzer based on Byte-Filtered Packet Inspection Mechanism for UW-ASN

  • Muminov, Sardorbek;Yun, Nam-Yeol;Park, Soo-Hyun
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.12
    • /
    • pp.1572-1582
    • /
    • 2011
  • The rapid growth of UnderWater Acoustic Sensor Networks (UW-ASNs) has led researchers to enhance underwater MAC protocols against limitations existing in underwater environment. We propose the customized robust real-time packet inspection mechanism with addressing the problem of the search for the data packet loss and network performance quality analysis in UW-ASNs, and describe our experiences using this approach. The goal of this work is to provide a framework to assess the network real-time performance quality. We propose a customized and adaptive mechanism to detect, monitor and analyze the data packets according to the MAC protocol standards in UW-ASNs. The packet analyzing method and software we propose is easy to implement, maintain, update and enhance. We take input stream as real data packets from sniffer node in capture mode and perform fully analysis. We were interested in developing software and hardware designed tool with the same capabilities which almost all terrestrial network packet sniffers have. Experimental results confirm that the best way to achieve maximum performance requires the most adaptive algorithm. In this paper, we present and offer the proposed packet analyzer, which can be effectively used for implementing underwater MAC protocols.

Optimization of coagulant dosing process in water purification system using neural network (신경회로망을 이용한 상수처리시스템의 응집제 주입공정 최적화)

  • Nam, Ui-Seok;Park, Jong-Jin;Jang, Seok-Ho;Cha, Sang-Yeop;U, Gwang-Bang;Lee, Bong-Guk;Han, Tae-Hwan;Go, Taek-Beom
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.6
    • /
    • pp.644-651
    • /
    • 1997
  • In the water purification plant, chemicals are injected for quick purification of raw water. It is clear that the amount of chemicals intrinsically depends on water quality such as turbidity, temperature, pH and alkalinity. However, the process of chemical reaction to improve water quality (e.g., turbidity) by chemicals is not yet fully clarified nor quantified. The feedback signal in the process of coagulant dosage, which should be measured (through the sensor of the plant) to compute the appropriate amount of chemicals, is also not available. Most traditional methods focus on judging the conditions of purifying reaction and determine the amounts of chemicals through manual operation of field experts using Jar-test data. In this paper, a systematic control strategy is proposed to derive the optimum dosage of coagulant, PAC(Polymerized Aluminium Chloride), using Jar-test results. A neural network model is developed for coagulant dosing and purifying process by means of six input variables (turbidity, temperature, pH, alkalinity of raw water, PAC feed rate, turbidity in flocculation) and one output variable, while considering the relationships to the reaction of coagulation and flocculation. The model is utilized to derive the optimum coagulant dosage (in the sense of minimizing turbidity of water in flocculator). The ability of the proposed control scheme validated through the field test has proved to be of considerable practical value.

  • PDF

Assessing the Influence Radius of a Water Treatment System Installed in a Reservoir Using Tracer Experiment and 3D Numerical Simulation (추적자 실험 및 3차원 수치모의를 이용한 저수지 수처리 장치의 영향반경 평가)

  • Park, Hyung Seok;Lee, Eun Ju;Ji, Hyun Seo;Choi, Sun Hwa;Chun, Se Woong
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.3-12
    • /
    • 2018
  • The objective of this study was to evaluate the radius of influence of effluent of water treatment system developed for the purpose of improvement of reservoir water quality using fluorescent dye (Rhodamine-WT) tracer experiment and 3-D numerical model. The tracer experiment was carried out in a medium-sized agricultural reservoir with a storage capacity of $227,000m^3$ and an average depth of 1.6 m. A guideline with a total length of 160 m was installed at intervals of 10 m in the horizontal direction from the discharge part, and a Rhodamine measurement sensor (YSI 6130, measurement range $0-200{\mu}g/L$) was used to measure concentration changes in time, distance, and depth. Experimental design was established in advance through Jet theory and the diffusion process was simulated using ELCOM, a three dimensional hydraulic dynamics model. As a result of the study, the direct effect radius of the jet emitted from the applied water treatment system was about 50-70 m, and the radius of physical effect by the advection diffusion was judged to be 100-120 m. The numerical simulations of effluent advection-diffusion of the water treatment system using ELCOM showed very similar results to those of the impact radius analysis using the tracer experiment and jet flow empirical equations. The results provide valuable information on the spatial extent of the water quality improvement devices installed in the reservoir and the facility layout design.

Fabrication or Si Diaphragm using Optimal Etching Condition of $N_2H_4-H_2O$ Solution ($N_2H_4-H_2O$ 용액의 최적 시작 조건을 이용한 Si diaphragm의 제작)

  • Ju, B.K.;Lee, Y.H.;Kim, H.G.;Oh, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.295-298
    • /
    • 1989
  • Using the anisotropic etching characteristics or $N_2H_4-H_2O$ solution, Si diaphragm was fabricated for the integrated sensor. The optimal composition and temperature of the solution in Si etching process was established to be 50mol% $N_2H_4$ in water at $105{\pm}2^{\circ}C$ for both higher etch rate(=$2.6{\mu}m/min$) and better surface quality of etched {100} planes. Under the optimal etching condition, the electrochemical etch stop technique was employed to form Si diaphragm for pressure sensor and diaphragm thickness was exactly controlled to $20{\pm}2{\mu}m$.

  • PDF

Development of Smart Remote Terminal Unit for Water Treatment SCADA System (상하수도 원격감시제어 시스템 구현을 위한 스마트 RTU의 개발 및 적용)

  • Jang, Sang-Bok;Lee, Ho-Hyun;Hong, Sung-Taek;Chun, Myung-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.24-30
    • /
    • 2014
  • In this paper, a new remote terminal unit(hereafter RTU) is proposed to manage a wide range of applications and a variety of sensors (eg, pressure, water quality, temperature and humidity sensors, the amount of pollutants, $CO_2$, etc.) to monitor and control the facility such as water treatment plant, intake and effluent pumping station, water tank and distribution network. Fault status of local sensor devices and network are alerted by using the embedded fault handling capabilities of the RTU in the system and also sent to the fault handling server, by which fault can be easily monitored to users. The developed system was applied to one of K-water branch offices in Geoje city and improved its reliability and stability for controlling and monitoring water facility.

Statistical Analysis of Water Quality in a Land-based Fish Farm (육상 수조식 양식장 수질 환경의 통계적 분석)

  • Kim, Hae-Ran;Ceong, Hee-Taek
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.6
    • /
    • pp.637-644
    • /
    • 2010
  • The purpose of this study is to analyze characteristics of water quality factor scientifically and develop the multiple regression model predicting dissolved oxygen to save periodic replacement costs for dissolved oxygen sensor. Correlation analysis using the environmental data obtained from 2 different land-based fish farms of the Geogeum-do, Geheung-gun coastal area during the periods from November 2008 to January 2009 shows that water temperature was negatively correlated with dissolved oxygen and pH butpH was positively correlated with salinity and dissolved oxygen. The information of Keumho fish farm in 2009 is presented by the tables which are monthly statistics of water quality factors and seasonable difference by the Duncan's post-test. Also we developed multiple regression model predicting dissolved oxygen, the usefulness of which was verified by the comparison graph between estimates and actual observations. The developed regression model shows that seawater temperature and salinity give negative affect to dissolved oxygen while pH gives positive affect to it. Lastly the seawater temperature has much higher explanatory power than pH factor.