• Title/Summary/Keyword: water-keeping test

Search Result 54, Processing Time 0.024 seconds

An Experimental Study on the Vertical Motion of a High-Speed Planing Craft in Regular Following Waves (선미 규칙파 중 고속 활주선의 연직면 운동에 대한 실험적 연구)

  • Kim, Dong-Jin;Rhee, Key-Pyo;You, Young-Jun;Park, Han-Sol
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.4
    • /
    • pp.496-507
    • /
    • 2010
  • It is well known that when a high-speed planing craft travels in following seas it experiences long-periodic motions due to low encounter frequency, and it often loses its course keeping stability. Therefore, it is necessary to study the sea-keeping performance and stability of it in the following seas. In this paper, the vertical motions of a planing craft were measured in following regular waves, and the test results were compared with the theoretical results. In the case of the same encounter frequency, non-dimensionalized motion amplitudes become larger as Froude number is higher, and non-dimensionalized motion amplitudes in head waves are larger than those in following waves. The mean values of the motions in following waves are similar to the running attitudes of a craft in calm water at the same Froude number.

Investigation on the Method of Evaluating the Resistance to Freezing and Thawing of Concrete Subjected Initial Frost Damage (초기동해를 받은 콘크리트의 내동해성 평가법에 대한 검토)

  • 고경택;장일영
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.4
    • /
    • pp.117-127
    • /
    • 1999
  • In concrete incorporating high volume ground granulated blast-furnace slag that has frozen at early age, to evaluated the results of resistance to freezing and thawing is very difficult because the hydration of the concrete increases over the duration of rapid freezing and thawing test. Hence, the dynamic modulus of elasticity of specimens after freezing and thawing will be favorable results unless the hydration effect is taken into consideration. In this study, a method of evaluating to the resistance to freezing and thawing of concrete subjected freezing at early age, in which the effect of hydration is modified for its increase during rapid freezing and thawing test, is investigated.

Effect of degree of compaction & confining stress on instability behavior of unsaturated soil

  • Rasool, Ali Murtaza
    • Geomechanics and Engineering
    • /
    • v.30 no.3
    • /
    • pp.219-231
    • /
    • 2022
  • Geotechnical materials such as silt, fine sand, or coarse granular soils may be unstable under undrained shearing or during rainfall infiltration starting an unsaturated state. Some researches are available describing the instability of coarse granular soils in drained or undrained conditions. However, there is a need to investigate the instability mechanism of unsaturated silty soil considering the effect of degree of compaction and net confining stress under partially and fully drained conditions. The specimens in the current study are compacted at 65%, 75%, & 85% degree of compaction, confined at pressures of 60, 80 & 120 kPa, and tested in partially and fully drained conditions. The tests have been performed in two steps. In Step-I, the specimens were sheared in constant water content conditions (a type of partially drained test) to the maximum shear stress. In Step-II, shearing was carried in constant suction conditions (a type of fully undrained test) by keeping shear stress constant. At the start of Step-II, PWP was increased in steps to decrease matric suction (which was then kept constant) and start water infiltration. The test results showed that soil instability is affected much by variation in the degree of compaction and confining stresses. It is also observed that loose and medium dense soils are vulnerable to pre-failure instability i.e., instability occurs before reaching the failure state, whereas, instability in dense soils instigates together with the failure i.e., failure line (FL) and instability line (IL) are found to be unique.

Effects of Ozone-Water Washing on the Quality of Melon (오존수 세척이 포장 참외의 품질에 미치는 영향)

  • Hwang Tae Young;Park Yoen Ju;Moon Kawng Deog
    • Food Science and Preservation
    • /
    • v.12 no.3
    • /
    • pp.252-256
    • /
    • 2005
  • For increasing shelf-life, melons with different washing and packaging were evaluated during storage at room temperature. Hardness and weight of melon was decreased during storage period and, after 12 days, severe rotten or decay appeared on melons except melon with ozone-water. Organoleptic test on color, appearance, taste and texture showed maximum values on melons eith ozone-water washing. Particularly, spots have been shown on all packaged melons in the later storage, except melons washed with ozone-water. According to these results, ozone-water washing was effective for keeping the high quality of melons.

A study on the hull form development of the G/T 340ton class high speed fishery patrol ship (G/T 340톤급 고속 어업지도선의 선형개발에 관한 연구)

  • 이귀주;이광일
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.221-226
    • /
    • 1997
  • This study was carried out for the hull form development of G/T 340ton class high speed fishery patrol ship by Chosun University at the Circulating Water Channel cooperatively with Korea Maritime Service. Same size of 15knots class fishery patrol ship was selected as a parent form (Model number : CU-015), and modified fore and after body to be suitable for the operation at 20 knots. To minimize the breaking wave in the vicinity of fore body at high speed zone, high bulb nose and slender fore body hull form was chosen as an initial condition. Meanwhile, to ensure the engine room space keeping high resistance-propulsion performance, U-type stern hull form was developed.

  • PDF

Investigation of two-phase natural circulation with the SMART-ITL facility for an integral type reactor

  • Jeon, Byong Guk;Yun, Eunkoo;Bae, Hwang;Yang, Jin-Hwa;Ryu, Sung-Uk;Bang, Yun-Gon;Yi, Sung-Jae;Park, Hyun-Sik
    • Nuclear Engineering and Technology
    • /
    • v.54 no.3
    • /
    • pp.826-833
    • /
    • 2022
  • A two-phase natural circulation test using SMART integral test loop (SMART-ITL) was conducted to explore thermo-hydraulic phenomena of two-phase natural circulation in the SMART reactor. Specifically, the test examined the natural circulation in the primary loop under a stepwise coolant inventory loss while keeping the core power constant at 5% of the scaled full power. Based on the test results, three flow regimes were observed: single-phase natural circulation (SPNC), two-phase natural circulation (TPNC), and boiler-condenser natural circulation (BCNC). The flow rate remained steady in the SPNC, slightly increased in the TPNC, and dropped abruptly and maintained in the BCNC. Using a natural circulation flow map, the natural circulation characteristic in the SMART-ITL was compared with those in pressurized water reactor simulators. In the SMART-ITL, a BCNC regime appeared instead of siphon condensation and reflux condensation regimes because of the use of once-through steam generators.

Greenhouse Heating Technology Development by using Riverbank Filtration Water (강변여과수를 이용한 온실난방기술 개발)

  • Moon, Jong-Pil;Lee, Sung-Hyoun;Kwon, Jin-Kyung;Kang, Youn-Ku;Ryou, Young-Sun;Lee, Su-Jang
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.6
    • /
    • pp.145-152
    • /
    • 2011
  • In order to heat greenhouse nearby river channel, riverbank filtration water source heat pump was developed for getting plenty of heat flux from geothermal energy. Recharging well, thermal storage tank with separating insulation plate and filtering tank for eliminating iron, manganese were mainly developed for making the coefficient of performance (COP) of heat pump higher. Heating system using riverbank filtration water source heat pump was installed at a paprika greenhouse in the Jinju region where a single fold of vinyl cover and 2 layers of horizontal thermal curtain were installed as a part of temperature keeping and heat insulation with a greenhouse area of 3,185 $m^2$. 320,000 kcal/h was supplied for performing a site application tests. A greenhouse heating test was performed from Feb. 1, 2011 to Apr. 30, 2011. As the result of that, COPh of the heat pump was measured in the range of 4.0~4.5, while COPS of the system was represented as 2.9~3.3. COP measured of the heat pump was very good and well responded to indoor heating temperature of the environment control system of a greenhouse.

A Study on the Combined Deterioration of Concrete subjected to Freezing-Thawing and Chloride Attack (동해와 염해를 동시에 받는 콘크리트의 복합열화에 관한 연구)

  • Kim Eun-Kyum;Choi Sang-Deok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.225-228
    • /
    • 2005
  • This paper was accomplished for analyzing the reason of the above deterioration happened on the deck of concrete bridge. The bridge was constructed at 660m above the sea level having more freezing and snowing days. Therefore, it is placed on the particular condition sprinkling $CaCl_2$ enough for keeping up with moderate traffic condition. When it is considered to the former condition, the bridge can be assumed to potentialities for combined deterioration with freezing-thawing under sprinkling deicing chemical. Core specimens were gathered from the concrete deck for clearing the reason of the above deterioration exactly, and it is used for various tests for measuring the compressive strength, elastic modulus, content of $Cl^-$, freezing-thawing at the fresh and salt water. As a result of freezing-thawing test, the specimen at the fresh water has over 90$\%$ of durability factor, but another specimen at 1$\%$ of salt water has 0$\%$ of durability factor at 140 cycles of the freezing-thawing. The result means that frost damage is sccelerated at the salt water. Therefore, the deterioration of the concrete deck is estimated to be occured by combined effects of freezing-thawing and chloride ion attack.

  • PDF

Thermal Response Test (TRT) interpretation and the status in Korea (열응답 실험 해석 및 국내 현황)

  • Shim, Byoung Ohan;Choi, Choonghyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.168.2-168.2
    • /
    • 2010
  • The growing market for geothermal heat pump system requires great consideration of quality control and assurance in design and construction. The borehole heat exchanger of GHP system should be sustainable, economical and ecological. Thermal Response Test (TRT) is a useful method for site investigation to obtain reliable data for a optimal system design from the technical and economical aspect. Intensive researches combined with exchange of experiences on an international level within the IEA ECES Annex 21 improved the technology. Major subjects on the interpretation of TRT are development of improved evaluation models, evaluation of the TRT with respect to geological layers and investigation of the influence of ground water. Current status of TRT in South Korea, as well as a new version of the Korean TRT standard test procedure was presented. TRT is mostly used for governmental supported projects with corresponds to more than 100 GCHP systems per year. More than 200 tests are applied, mostly on single U-tube heat exchangers (about 95%). Bentonite is the most common grouting to be used. KIGAM (Korea Institute of Geoscience & Mineral Resources) is also keeping a GIS geological and geothermal database. In the institute also laboratory measurements of rock properties are carried out. About 90% of the laboratory measurements of the rock heat conductivity shows higher values than the in-situ TRT.

  • PDF

Effect of a Suspended Overhead Sprayer with Sector Formed Injection Nozzles on Spraying Uniformity (두상관수장치의 부채꼴분사노즐 설치위치가 살수균일성에 미치는 영향)

  • 김명규;정태상;민영봉
    • Journal of Bio-Environment Control
    • /
    • v.8 no.4
    • /
    • pp.223-231
    • /
    • 1999
  • The one of basic functional conditions of suspended overhead sprayer, which is openly made use of irrigating on bedding plants in greenhouse, is to be kept the growing uniformity of bedding plants by making uniformly the spraying irrigation depending on the distribution of sprayed water. This study was performed to find out the optimum position of sector formed injection nozzle which is placed from the top of plant 0 the tip of the nozzle to keep spraying uniformity. The test of spraying distribution using a overhead sprayer, which was installed in a row of sector formed injection nozzles, was performed The measuring factor to represent spraying distribution was the water weight filled in each cup when the overhead sprayer was moving across the upside of the cups which were placed directly under the nozzles on keeping the distance from nozzle tip. The test results were as following , The standard mr of weights of each cup filled with spraying water was lower values at Position far from more than 60cm under nozzle tip. The driving speed variation of sprayer was not effected on spraying uniformity but the spraying water weight was inversely proportioned to the speed. To make best spraying uniformity, it was represented that the tip of the nozzle is positioned to keep the distance which the top of plants is placed at the second cross point of each injection sector of nozzles.

  • PDF