An Analysis on Remediation of Soil Contaminted with Cobalt by Solvent Flushing

  • Kim, Gyenam;Kyungsuk Suh;Huijun Won;Joonbo Shim;Wonzin Oh
    • Nuclear Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.342-349
    • /
    • 2000
  • A soil whose texture is silt loam was collected for the study from an area around a nuclear facility in Korea. The equilibrium sorption coefficient between Co$^{2+}$in water and the soil was 1.51/kg, on the other hand, that between Co$^{2+}$ in EDTA and the soil was 0.21/kg. The values calculated by the developed nonequilibrium sorption code corresponded to the experimental values better than those calculated by the existing equilibrium sorption code. When an EDTA solution was used as a solvent to decontaminate Co$^{2+}$ in the soil column, the relative Co$^{2+}$ concentrations of the effluent were higher at 2~10 pore volumes than those of the case using water. The soil in the column was decontaminated by 95.5% of the total amount of Co$^{2+}$ after being flushed with EDTA solution of 20 pore volumes.e volumes.

  • PDF

A Study on Hydro Energy Development of Discharged Cooling Water at the Power Plant (발전소 온배수의 수력에너지 개발에 관한 연구)

  • Kang, K.S.;Lee, D.S.;Kim, J.Y.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.813-818
    • /
    • 2005
  • Cooling seawater of thermal power plant which amounts about 5 cms per 100 MWe has hydro energy of about 3,000 kW at the thermal power plant complex, but this useful hydro energy has not been developed. Therefore, the feasibility study on hydro energy development of three power plants located in the southern and western coast of Korea was performed. Three target power plants are Samcheonpo, Boryeong and Hadong thermal power plant. The design head to discharge cooling water by gravity and the head caused by tidal level in the southwestern coastal area, could be used for the production of electric power. The various alternatives were studied and technical feasibility and economical efficiency were clearly proved.

  • PDF

Basic Design and Performance Analysis of an Solar Absorption Chiller (태양열 구동 흡수식 냉동기의 기본설계 및 성능분석)

  • Baek, N.C.;Yoon, E.S.;Joo, M.C.;Jeong, S.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.107-112
    • /
    • 1998
  • Basic design of a solar driven absorption cooling machine(SDACM) with a cooling capacity of 5 USRT was carried out. The SDACM is a single effect cycle driven by low temperature hot water from solar collectors. The SDACM design data were calculated by the steady state simulation program which was developed in this study The variation of COP and cooling capacity of the SDACM were investigated at different off-design conditions. Both the cooling capacity and the system COP were improved with decreasing cooling water temperature. If hot water temperature was increased, the cooling capacity was improved but the system COP was found to be decreased. The decrease of the system COP were basically caused by increased thermal loads in the system components.

  • PDF

Sum-Rate Optimal Power Policies for Energy Harvesting Transmitters in an Interference Channel

  • Tutuncuoglu, Kaya;Yener, Aylin
    • Journal of Communications and Networks
    • /
    • v.14 no.2
    • /
    • pp.151-161
    • /
    • 2012
  • This paper considers a two-user Gaussian interference channel with energy harvesting transmitters. Different than conventional battery powered wireless nodes, energy harvesting transmitters have to adapt transmission to availability of energy at a particular instant. In this setting, the optimal power allocation problem to maximize the sum throughput with a given deadline is formulated. The convergence of the proposed iterative coordinate descent method for the problem is proved and the short-term throughput maximizing offline power allocation policy is found. Examples for interference regions with known sum capacities are given with directional water-filling interpretations. Next, stochastic data arrivals are addressed. Finally, online and/or distributed near-optimal policies are proposed. Performance of the proposed algorithms are demonstrated through simulations.

Viability of HVAC System for Energy Conservation in High Density Internal-load Dominated Buildings (고밀도 내부부하 중심 건물의 에너지 절약적 공조방식에 대한 연구)

  • Cho, Jin-Kyun;Jeong, Cha-Su;Kim, Byung-Seon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.8
    • /
    • pp.530-537
    • /
    • 2010
  • With the advancement of technology, the density of IT equipment, heat load and power consumption continue to increase in high density internal-load dominated buildings as datacenters. To improve the HVAC system's energy performance and efficiency, there is a need to find methods of using outside air. Through cooling tower control that is based on outside wet-bulb temperature, the water-side economizer made it possible to achieve a maximum energy performance improvement of about 16.6% over the basic chilled water system, whereas the air-side economizer, through control based on outdoor air enthalpy, made it possible to achieve about 42.4% improvement.

Design and Manufacture of Direct Solar Hot Water Heating System Using Pressure Relief Tube and Expandable Header (감압 튜브 및 팽창헤더를 이용한 직접식 태양열 온수기의 설계 및 제작에 관한 연구)

  • Chun, Won-Gee;Kim, Hyung-Taek
    • Solar Energy
    • /
    • v.20 no.3
    • /
    • pp.51-60
    • /
    • 2000
  • This paper deals with the design, construction and operation of a direct solar hot water heating system developed to harness the solar energy more effectively. The system introduced here uses a unique network of riser tubes and header pipes apart from the existing concept to exploit the physical properties of water which expands when it freezes. It also employs a special pressure relief mechanism for the header to prevent its breakage due to freezing. A number of tests are made to assure its functional reliability during frigid weather conditions and its superior performance over indirect systems.

  • PDF

Overview and Trend of Small Hydropower Development in Korea (국내 소수력 발전 기술현황과 전망)

  • Lee, Gyeong-Bae;Kim, Young-Gue;Paik, Doo-Hyun;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.762-764
    • /
    • 2003
  • In Korea, over 97% of local energy demand is imported from other countries. And we have to lift the energy independence level up to 5% with replacement energy (renewable energy) such as solar, small hydropower, etc. by 2011 according to the energy agreement made in Kyoto Protocol. So, we proposed some opinions such as the better improvement of small hydropower industry the people' view, cooperation among industry/university/research institutes, remote control/maintenance and goverment's legislature and supporting system etc.

  • PDF

Study on visualization of water mixing flows in a digester equipped with a vertical impeller by using radiotracers

  • Jung, Sung-Hee;Moon, Jinho;Park, Jang-Guen;Lim, Jae Cheong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.1
    • /
    • pp.170-177
    • /
    • 2020
  • A mixer with a new concept design has been adapted into water treatment plants. It reportedly cuts down the energy consumption of the mixer by the new mixer, which moves vertically and creates internal flows toward its bottom. However, no experimental observations have been made on the internal flow caused by a vertical impeller. In this study, a radiotracer experiment, radioactive particle tracking (RPT) technique, and particle image velocimetry (PIV) were carried out to visualize the flow in the mixer, and compared to each other. The results show that the flow patterns from these techniques are very similar to each other, and the performance of the mixer was good enough to mix the inner materials.

An Analytical Study on Solar Energy Systems at the Energy Eco-Science Center (에너지생태과학관의 태양에너지 시스템 분석 연구)

  • Lim, Sang-Hoon;Chun, Won-Gee;Hyun, Jun-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.593-596
    • /
    • 2006
  • This paper introduces various natural energy systems installed at the Eco-Science Center in Geumsan near Taejon. The center, especially, features different solar energy systems to harvest the solar energy to its full extent. Such passive schemes as direct gain and at lacked sun space are applied along with active solar ingredients using flat plate and double skin solar collectors. Space and water heating depends very little on the conventional means. Also a number of photovoltaic modules deployed within its premise supplies power to drive a water pump for the biotop. Combined with other natural energy utilizing systems, the solar energy systems make an exemplary model of a self sustainable public facility which is the first of its kind in Korea.

  • PDF

The study on Estimate of Tidal Power Using Matlab T-tide Based on Tide Prediction (Matlab T-tide를 이용한 조위예측기반의 조력발전량 산정에 관한 연구)

  • Lee, Sung-Hun;Kwak, Hee-Jin;Kim, Jong-Deug;Lee, Eun-Chun;Kim, Ji-Chan;Jeon, Kyeong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1048-1049
    • /
    • 2015
  • The sihwa tidal power plant is the first tidal power plant in korea and the biggest of the world. The tidal power turbine is operated by tidal energy. The tidal energy is generated by the relative motion of the earth and celestial masses specially the sun and the moon, which interact via gravitational forces. The tidal power is estimated by the predicted the tidal amplitude and phase. This paper gives a process of estimate of tidal power using Matlab T-tide based on tide prediction. The proposed method is tested using actual recorded data comparing to predicted date.

  • PDF