• 제목/요약/키워드: water vapor resistance

검색결과 120건 처리시간 0.022초

목본식물 형성층 전기저항에 영향을 주는 환경 요인 (Effects of Environmental Factors on the Cambial Electrical Resistance of Woody Plants)

  • 김동욱;김민수;이부용
    • 한국조경학회지
    • /
    • 제35권3호
    • /
    • pp.105-113
    • /
    • 2007
  • This study was conducted to analyze the effects of environmental factors such as soil moisture, light intensity, temperature and humidity on changes in cambial electrical resistance. To improve data quality, cambial electrical resistance was continuously measured at fixed points by using a data logger isolated from alternating current. The relationship between environmental factors and changes in cambial electrical resistance was also analyzed. The results are as follows: 1. Cambial electrical resistance is highly correlated to the temperature of the measured area(r=-0.934). Therefore, temperature compensation is needed to analyze the effects of other environmental factors on cambial electrical resistance changes. 2. If temperature is compensated for, the change of cambial electrical resistance is highly correlated to water vapor pressure(r=-0.836). 3. If temperature and humidity are compensated for, the change of cambial electrical resistance is highly correlated to intensity of light(r=-0.738). 4. Diurnal deviation of soil water potential is not more significantly related than the change of cambial electrical resistance. However, in the long-term, soil water potential and cambial electrical resistance are highly correlated(r=-0.831). This indicates that soil moisture significantly influences the long-term change of cambial electrical resistance.

발수발유가공처리가 부직포의 차단성능에 미치는 영향 (Effect of Water-and Oil-Repellent Finish on Barrier Properties of Nonwoven Fabrics)

  • 조길수;최종명
    • 한국의류학회지
    • /
    • 제17권4호
    • /
    • pp.577-586
    • /
    • 1993
  • Pesticide protective clothing has not been frequently worn due to its lack of thermal comfort. It is important to develop fabrics which can allow the wearer to work in comfort. One of the possible way to achieve the goal is to produce fabrics with a water- and oil-repellent finish which would resist pesticide penetration but maintain some breathability. The purpose of this study were to evaluate the pesticide barrier properties of untreated and water- and oil-repellent finished nonwoven fabrics. Three types of nonwoven fabrics(Tyvek, Sontara and Kimlon) were used as test specimens. By pad-dry-cure method, each of the specimen was treated with fluorocarbon. The pesticide barrier properties (amount of pesticide penetration and residue) were measured by the gas chromatography. The performance properties of untreated and treated specimens were evaluated with respects to water pepellency(KS K 0590), oil repellency(AATCC 118), water resistance(KS K 0591, AATCC 42), water vapor transmission (KS A 1013) and air permeability(KS K 0570). The results of this study were as follows : 1) The untreated Sontara showed much more amount of pesticide penetration than untreated Tyvek and Kimlon, while the treated Sontara showed little amount of pesticide penetration. 2) After laundering, the amount of pesticide residue in the untreated and treated Sontara was less than that in Tyvek and in Kimlon. 3) Water- and oil-repellent finish improved water repellency, oil repellency, and water resistance of specimens. 4) The untreated Sontara and Kimlon showed higher water vapor transmission and air permeability than untreated Tyvek. Water vapor transmission and air permeability of treated specimen decreased compared to those of untreated.

  • PDF

전기 저항열을 이용한 유류 오염토 복원공정 적용을 위한 토양의 가열특성 연구 (Heating Characteristics of the Soils for the Application of Electrical Resistance Heating with Soil Vapor Extraction)

  • 윤여복;고석오;박기호;박민호
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제11권1호
    • /
    • pp.45-53
    • /
    • 2006
  • 본 연구에서는 토양의 전기가열 특성을 실험을 통해 규명함으로서, 전기저항열을 이용한 토양증기추출법을 실제 현장에 적용 시 토양가열 효율을 증가시키는 방안을 도출하기 위하여, 반응조를 이용한 토양 종류별 자체 특성에 따른 가열 특성과 외부에서의 전기적 특성의 조절을 통한 가열 특성을 살펴보았다 토양의 업자가 작을수록, 토양 내 이 온이 풍부할수록 전기가열 효율이 증가되었으며, 토양이 물로 포화된 경우에도 전기 가열 효율이 증가하였으나 공극률 이상으로 수분이 있는 경우는 오히려 효율이 떨어졌다. 전압이 증가할수록, 전극 사이가 짧아질수록, 유류 오염된 토양일수록 효율은 증가되었다 본 연구에서는 초기 전류와 전기전도도의 정량적 상관관계를 도출함으로써 직접적인 전기가열 실험 없이 전기전도도로 반응조 내 토양이 $100^{\circ}C$ 온도 상승의 가능성을 예측할 수 있게 됐다.

종이내 수분확산(제1보)-종이의 방습성 평가를 위한 수증기의 정류상 확산 실험- (Molecular Diffusion of Water in Paper( I )-Steady-State Diffusion Experiment for the Evaluation of Water Vapor-proof Properties of Paper-)

  • 윤성훈;전양;오세균;서영범
    • 펄프종이기술
    • /
    • 제30권1호
    • /
    • pp.59-70
    • /
    • 1998
  • A steady-state molecular diffusion experiment was conducted to evaluate the water vapor proof properties of paper Handsheets prepared from unbleached Itraft pulps(UKP) and old newspapers(ONP) and four different types of polymer-laminated white duplex board were tested under appropriate standard conditions. The diffusivity was determined on the basis of the Fickean first law. Results obtained from this study can be summarized as follows ; 1. The diffusivity data for handsheets showed about $10^{-5}cm^2/min$. whereas polymer-laminated paperboards had remarkably improved water-vapor resistance with about $10^3 to 10^4$ times lower diffusivity : 2. Sheet basis weight, wet-swelling and sizing degree had little influence on the diffusivity of paper; 3 Linear relationship existed between sheet density and diffusivity, and, 4. Highly sfgnificant linear relationship could be observed between diffusivity and Darcy s gas permeability. Results indicate that diffusivity, an intrinsic property of paper, can provide a valuable information for precise evaluation and improved quality control of water-vapor proof properties of paper.

  • PDF

Enhancement of the Water-resistance and Physical Properties of Sodium Alginate Film

  • Kim, Eun-Jung;Kim, Byung-Yong;Rhim, Jong-Whan
    • Food Science and Biotechnology
    • /
    • 제14권1호
    • /
    • pp.108-111
    • /
    • 2005
  • To improve water-resistance and physical properties of sodium alginate film, effects of sodium alginate and plasticizer concentrations, divalent cation types and concentrations, and immersion time of films into divalent cation solutions on sodium alginate films were evaluated, based on elongation strength (ES), elongation rate (E), water vapor permeability (WVP), and water solubility (WS). Film made from 1.5% sodium alginate solution (w/w) had low WVP and WS, which are optimal characteristics for application of film preparation. Addition of plasticizer increased E and WS. Less than 2% $CaCl_2$ addition and 15min immersion time reduced WVP, WS, and E significantly (p<0.05). Sodium alginate films treated with $CuCl_2$, and $ZnCl_2$ solutions had lower WVP and WS, whereas $MgCl_2$ had no influence on improving water resistance of films.

풍속 존재 시 쾌적보온성 의복의 온열특성에 관한 연구 (A Study on the Insulation of Thermal Clothing Under Dynamic Air Condition)

  • 송민규;권명숙
    • 복식
    • /
    • 제58권9호
    • /
    • pp.29-37
    • /
    • 2008
  • The purpose of this study was to investigate insulation of thermal clothing under still and dynamic air conditions(with 2.1m/sec air velocity) and decrease of insulation in both conditions, to analyze correlations among them, and to estimate insulation and decrease of insulation using factors, such as fabric insulation, fabric weight, clothing weight, air permeability, and water vapor resistance. A total of 25 kinds of clothing were tested(9 types for suits, 6 types of jacket, 5 types for shirts, and 5 types for trousers). The results of this study were as follows; Thermal resistance of clothing under the dynamic air condition decreased comparing to that of clothing under still air condition in all types of clothing. Decrease in shirts was the biggest(47.5%), followed by suits(39.51%), trousers(37.48%), and jackets(34.49%) in sequence. Thermal resistance of clothing under dynamic air condition showed very high correlation(0.98, p<0.01) with that of clothing under still air condition, followed by thermal resistance of fabric(0.86, p<0.01). Decrease in thermal resistance of clothing showed the highest correlation with air permeability. It didn't show correlation with other factors. Regression analysis showed that fabric thickness would be useful factor for estimating thermal resistance of clothing and air permeability also would be useful factor for estimating decrease in thermal resistance of clothing.

Creation of Diamond/Molybdenum Composite Coating in Open Air

  • Ando, Yasutaka;Tobe, Shogo;Tahara, Hirokazu
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1313-1314
    • /
    • 2006
  • For improvement of wear resistance property of atmospheric thermal plasma sprayed molybdenum (Mo) coating, diamond deposition on the atmospheric plasma sprayed molybdenum coating by the combustion flame chemical vapor deposition (CFCVD) has been operated. In this study, to diminish the thermal damage of the substrate during operation, a thermal insulator was equipped between substrate and water-cooled substrate holder. Consequently, diamond particles could be created on the Mo coating without fracture and peeling off. From these results, it was found that this process had a high potential in order to improve wear resistance of thermal sprayed coating.

  • PDF

PP/Tencel/흡한속건PET/하이브리드 복합사 구조가 고감성 의류용 직물의 물성에 미치는 영향 (Effect of Hybrid Yarn Structure Composed of PP/Tencel/Quick dry PET on the Physical Property of Fabric for High Emotional Garment)

  • 김현아;손황;김승진
    • 한국의류산업학회지
    • /
    • 제17권3호
    • /
    • pp.462-475
    • /
    • 2015
  • This paper investigated the characteristics of the physical properties of woven fabrics according to the yarn structure and fibre property. It was found that wicking property of woven fabrics made of sheath/core hybrid yarn were better than those of siro spun and siro-fil hybrid yarns, which was caused by platform for transport of moisture vapor by filaments on the core part of sheath core hybrid yarns. In drying property, the fabric specimen woven by PP/Tencel sheath core hybrid yarns as a warp and Coolmax/Tencel spun yarn as a weft showed quick drying property, which was caused by the sheath core hybrid yarn structure as drainage of water moisture and coolmax fibre characteristics as quick dry material. Concerning to breathability and thermal conductivity as heat transport phenomena, it was observed that breathability of fabrics woven with hybrid yarns such as sheath core and siro-fil in the warp and hi-multi filaments in the weft showed the lowest water vapor resistance, which was explained as due to for air gap in the fibres of the spun yarns to restrict the wet heat transport from perspiration vapor. Thermal conductivities of the fabrics woven with PET/Tencel siro-fil yarns in the weft and hybrid yarns such as sheath core and siro-fil in the warp revealed the highest values, which was observed as due to higher thermal conductivity of PET than PP and more contact point between fibres in the siro-fil and sheath core hybrid yarns.

Effect of Coating Methods on the Properties of Poly(lactide)-coated Paperboard: Solution Coating vs. Thermo-compression Coating

  • Rhim, Jong-Whan
    • Food Science and Biotechnology
    • /
    • 제18권5호
    • /
    • pp.1155-1160
    • /
    • 2009
  • Poly(lactide) (PLA)-coated paperboards were prepared by solution coating and thermo-compression coating methods and their effect of coating on the packaging properties such as tensile, water resistance, water vapor barrier, and heat sealing properties was tested. Compared with uncoated control paperboard, tensile strength (TS) of PLA-coated paperboard increased profoundly (2.2-2.6 folds) with slight increase in elongation at break (E). Water absorptiveness (WA) of the paperboard decreased 74-170 folds and water vapor permeability (WVP) decreased 6.3-22.1 folds by coating with PLA, which indicates an increase in the hydrophobicity of the surface of paperboard. Compared with polyethylene (PE)-coated paperboard, both PLA-coated paperboard exhibited 2.3 time higher heat sealing strength. In addition, the PLA-coated paperboards showed equal or higher wet TS than PE-coated paperboard. All the test results showed that the paperboard coated by the thermo-compression coating method was similar to or better than those of coated by the solution coating method.

편성물의 섬유의 종류, 실의 굵기 및 니트타입에 따른 투습완충능력 (Effect of Fiber Content, Yarn Size and Construction of Knit Fabrics on the Buffering Capacity against Water Vapor)

  • 유화숙;허윤숙;김은애
    • 한국의류학회지
    • /
    • 제20권1호
    • /
    • pp.228-238
    • /
    • 1996
  • The purpose of this study was to evaluate the effect of chacteristics of knit fabrics on the microclimate of the skin simulating system. To determine the effect of characteristics of knit fabrics, vapor state of sweat pulse was simulated in the closed system. Different contents of fibers such as cotton, wool and polyester with different yarn size and knit types were chosen for specimens. The changes of humidity and temperature of air layer in the simulated systems were measured. Buffering indices, $K_d$ and $\beta_r$, were determined by considering $\alpha_p, \DeltaP_{max}, t_{max}, and tan\beta$. Physical properties of knit fabrics such as thickness, porosity, air resistance and moisture vapor transport were measured. Results showed that vapor pressure of wool was lower than cotton or polyester This was attributed to the hydrophilicity of wool which absorbed moisture rather quickly and retained in the knit fabric. The time to decrease vapor pressure was faster for polyester than cotton or wool. As a result, $K_d$ was in the order of wool> polye, item> cotton. $\beta_r$ of wool was rower than cotton or polyester due to its lowers porosity and slower desorption rate. For the yarn size, $K_d$ was in the order of 80's> 60's> 30's; thinner and lighter yarn showed better water vapor transport property. For knit type, buffering capacity of single jersey was better than interlock knit fabric. Statistical analysis showed that the air permeability was the most influential factor far the water vapor transport properties.

  • PDF