• Title/Summary/Keyword: water temperature sensor

Search Result 292, Processing Time 0.025 seconds

Characteristic analysis of a thermochromic material based fiber-optic temperature sensor for measuring temperature of subsurface water (열변성 물질을 이용한 지하수 온도 측정용 광섬유 온도센서의 특성분석)

  • Seo, Jeong-Ki;Yoo, Wook-Jae;Cho, Dong-Hyun;Jang, Kyoung-Won;Heo, Ji-Yeon;Lee, Bong-Soo;Koh, Yong-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.467-474
    • /
    • 2009
  • In this study, we describe the feasibility of developing a fiber-optic temperature sensor using a thermochromic material such as 2,4,5-triphenylimidazole or also called Lophine. A sensor-tip is fabricated by mixing of a Lophine powder, which has a non-toxic and hydrophobic characteristics, and an epoxy resin. The temperature change in the sensor-tip gives rise to a change in the optical absorbance of the Lophine, and the transmittance of a light through the Lophine is also changed. We have measured the intensities of modulated lights due to the change of optical absorbance of the Lophine by using of a photo-multiplier tube(PMT). The relationships between the temperatures and the output voltages of PMT are determined to measure the temperature of water. The measurable temperature range of the fiber-optic sensor is from 5 to $30^{\circ}C$.

Estimation of Water Quality of Fish Farms using Multivariate Statistical Analysis

  • Ceong, Hee-Taek;Kim, Hae-Ran
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.4
    • /
    • pp.475-482
    • /
    • 2011
  • In this research, we have attempted to estimate the water quality of fish farms in terms of parameters such as water temperature, dissolved oxygen, pH, and salinity by employing observational data obtained from a coastal ocean observatory of a national institution located close to the fish farm. We requested and received marine data comprising nine factors including water temperature from Korea Hydrographic and Oceanographic Administration. For verifying our results, we also established an experimental fish farm in which we directly placed the sensor module of an optical mode, YSI-6920V2, used for self-cleaning inside fish tanks and used the data measured and recorded by a environment monitoring system that was communicating serially with the sensor module. We investigated the differences in water temperature and salinity among three areas - Goheung Balpo, Yeosu Odongdo, and the experimental fish farm, Keumho. Water temperature did not exhibit significant differences but there was a difference in salinity (significance <5%). Further, multiple regression analysis was performed to estimate the water quality of the fish farm at Keumho based on the data of Goheung Balpo. The water temperature and dissolved-oxygen estimations had multiple regression linear relationships with coefficients of determination of 98% and 89%, respectively. However, in the case of the pH and salinity estimated using the oceanic environment with nine factors, the adjusted coefficient of determination was very low at less than 10%, and it was therefore difficult to predict the values. We plotted the predicted and measured values by employing the estimated regression equation and found them to fit very well; the values were close to the regression line. We have demonstrated that if statistical model equations that fit well are used, the expense of fish-farm sensor and system installations, maintenances, and repairs, which is a major issue with existing environmental information monitoring systems of marine farming areas, can be reduced, thereby making it easier for fish farmers to monitor aquaculture and mariculture environments.

Study in the Development of Motion Recognition Tap-water using Ultrasonic Sensors (초음파 센서를 이용한 모션 인식 수도꼭지 개발 및 연구)

  • Kim, Dong-Hyun;Ryu, Jae-Hoo;Ju, Jong-Soo;Ahn, Jong-Pil;Kim, Jae-Wook
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.2
    • /
    • pp.309-316
    • /
    • 2022
  • Advances in technology have improved people's lives comfortably and have developed more easily, safely and simply. We usually turn on hot water to set the temperature of the water in the bathroom and gradually adjust the temperature to find the temperature we want with our skin. In this situation, I thought, "What if there is a device that can see the temperature of water with my eyes and help with the interior of the bathroom while including a safe system," and tried to create a system that values stability. For example, if a child accidentally changes the temperature of the water to high temperature while washing, he or she can get burned. And the biggest purpose is to secure better safety by adding LCDs and LEDs so that we can visually know the temperature before feeling it tactilely. As a result of the experiment, there was no error between the temperature detected by the water temperature sensor and the temperature displayed on the LCD, and no error occurred up to 27 cm in the distance measurement experiment using the ultrasonic sensor. There has been an error of about 2% since 28cm or older, but there is no significant inconvenience in using it within the category of faucets.

Agricultural drought monitoring using optical sensor-based soil moisture (광학센서 기반의 토양수분을 이용한 농업적 가뭄 감시)

  • Sur, Chan Yang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.296-296
    • /
    • 2022
  • 농업적 가뭄은 토양의 수분함량(토양수분)이 마르기 시작하면서 식생 활동에 영향을 주는 것으로 정의할 수 있다. 광범위한 농업적 가뭄을 판별하기 위해 인공위성 자료를 토대로 토양수분을 산정하고 이를 이용해 가뭄지수를 산정하고, 가뭄 상태를 판별한다. 기존 인공위성 기반의 토양수분의 경우, microwave sensor에서 제공되는 밝기온도(brightness temperature)를 통해 토양수분을 추정하는 방식이 일반적으로 활용되었다. 하지만, microwave sensor에서 제공되는 자료들의 공간해상도가 10 km 이상이기 때문에, 한반도나 더 작게는 유역 단위, 행정 단위별 가뭄 분석을 하기에는 적합하지 않다. 이에 본 연구에서는 공간 해상도 500m의 광학센서(visible infrared imaging radiometer suite sensor (VIIRS))에서 제공되는 지표면 온도(land surface temperature)와 지표 반사도(land surface albedo) 자료들을 조합하여 토양수분을 산정하는 방식을 제안하고, 산출된 토양수분으로 농업적 가뭄을 모니터링한 결과를 제시하고자 한다. 기존의 microwave sensor로 산출된 토양수분 결과 값과의 비교 및 검증을 통해 광학센서를 통한 토양수분 산출물의 한반도 내 적용성을 확인할 수 있다.

  • PDF

Notify boiling water by using TMP36 sensor

  • Lau, Shuai
    • Korean Journal of Artificial Intelligence
    • /
    • v.4 no.1
    • /
    • pp.8-10
    • /
    • 2016
  • These days, citizens have a lot of ways to get access to IT. In the past, they tended to neglect IT that was thought to be difficult. But, currently, everyone can manufacture and get access not only software but also hardware when he has an idea. Arduino is used. Rinnai had recently released new product named Smart Sensor Range. Safe consumer who gave priority to the safety made new trend gave attention to fire prevention and smart sensor range. The ones who buy gas range prefer safety to economic advantage and/or fire power. The safety system does not always prevent fire accident. This study makes design and produces alarm that perceives temperature of pot when boiling. Not only temperature sensor but also alarm sensor was used to make alarm of boiling water and to give convenient living life. The arduino can be used at practical life to make products for various kinds of people. The invention can give convenience to housewives at kitchen, children and many persons making use of gas range. Another function can be added to develop. This arduino can develop a lot of products by using the study and other designs.

Design Method for Improving Sensitivity of Film-type Level Sensors (필름형 레벨센서의 민감도 향상을 위한 설계 방법)

  • Byeongkon Kim;Sookwan Jang
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.5
    • /
    • pp.373-377
    • /
    • 2024
  • To increase the sensitivity of film-type level sensors for water-level measurements, a Wheatstone bridge comprising a half-bridge circuit with a new film-type level sensor design containing four resistors and two electrodes was employed. The proposed film-type level sensor included a temperature compensation feature and demonstrated improved sensitivity owing to a two-fold increase in the voltage output. Furthermore, a repetition error of less than 1.0% was observed for water levels. As the change in resistance varied linearly with the water level, a linear function was derived to represent their relation. Using this derived formula, water level measurements that were twice as precise as those yielded by commercial products were achieved.

A Study on the development of big data-based AI water meter freeze and burst risk information service (빅데이터 기반 인공지능 동파위험 정보서비스 개발을 위한 연구)

  • Lee, Jinuk;Kim, Sunghoon;Lee, Minjae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.24 no.3
    • /
    • pp.42-51
    • /
    • 2023
  • Freeze and burst water meter in winter causes many social costs, such as meter replacement cost, inability of water use, and secondary damage by freezing water. The government is making efforts to modernize local waterworks, and in particular, is promoting SWM(Smart Water Management) project nationwide. In this study suggests a new freeze risk notification information service based on the temperature by IoT sensor inside the water meter box rather than outside temperature. In addition, in order to overcome the quantitative and regional limitation of IoT temperature sensors installed nationwide, and AI based temperature prediction model was developed that predicts the temperature inside water meter boxes based on data acquired from IoT temperature sensors and other information. Through the prediction model optimization process, a nationwide water meter freezing risk information service was convinced.

Fiber optic distribution temperature sensing in a borehole heat exchanger system (광섬유 센서를 이용한 지중 열교환기 시스템 온도 모니터링)

  • Shim, Byoung-Ohan;Lee, Young-Min;Kim, Hyoung-Chan;Song, Yoon-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.451-454
    • /
    • 2006
  • Fiber optic distributed temperature sensing and thermal line sensor are applied in an observation borehole and a loom deep borehole heat exchanger. For the case of permanently installed system fiber optic DTS is very useful. By comparing with TLS, fiber optic DTS shows good accuracy and reliability. Ground water flow can give influences at heat exchange rate of the heat pump system. According to the hydraulic characteristics and temperature-depth profile, we consider that temperature-depth profile do not seem to be dependent on ground water flow. A permanent installation of fiber optic cable is expected as a reliable temperature measurement technique in a borehole heat exchanger system.

  • PDF

Development of a measurement device of water level at the bottom of fuel tanks using an optical cable sensor. (대용량 탱크에서 물과 유류의 이중 액면 높이 계측용 센서 개발)

  • 김진만;김희식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.471-474
    • /
    • 2002
  • A fuel tank contains water at the bottom under the fuel. The water comes from humidity by temperature change of inside and outside of tank. So it is necessary to measure both level to check precise amount of oil. But measuring instrument for level of water and fuel is not available yet. Since the fuel is inflammable, the sensor system must not include any electric circuits in the fuel tank. Optical cable sensor can satisfy this non-explosive condition. The displacement of a float changing by water level makes bending curvature of optical cable different. As the float rise up, the optical cable is bent more and the light signal in the cable decreases. The reduction of light signal is detected and it is converted into the change of water level. The output signal from a photo diode shows the proportional relation of water level. The increase of sensor voltage as a unit of ㎷ follows the level position of the float that is located between water and gasoline in the tank.

  • PDF

A Study on multi-channel temperature monitoring for the detection of leakage or seepage in dam body (댐 침투수 탐지를 위한 멀티 채널 온도 모니터링 연구)

  • Oh, Seok-Hoon;Kim, Jung-Yul;Park, Han-Gyu;Kim, Hyoung-Soo;Kim, Yoo-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1211-1218
    • /
    • 2005
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF